Setra Model 265 Differential Pressure Transducer Range 0- 50 Pac | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
More Information:
|
Setra Model 265 Differential Pressure Transducer Range 0- 25 Inch | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
|
Setra Model 265 Differential Pressure Transducer Range 0- 10 Inch | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
Features:
More Informations:
|
Setra Model 265 Differential Pressure Transducer Range 0- 2.5 Inch | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
|
Setra Model 265 Differential Pressure Transducer Range 0- 1 Inch | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
|
Setra Model 265 Differential Pressure Transducer Range 0- 0.5 Inch | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
|
Setra Model 265 Differential Pressure Transducer Range 0- 25 Pac | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
More Information:
|
Setra Model 265 Differential Pressure Transducer Range 0- 50 Inch | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
Features:
More Information:
|
Setra Model 265 Differential Pressure Transducer Range 0- 5 Inch | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage
|
Setra Model 265 Differential Pressure Transducer | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Setra Systems 265 pressure transducers sense Differential or gauge static pres sures andconvert this pressure difference to a proportional electrical output.The 265 is offered witha high level 0-5 VDC output or a 4-20 mA output.It is also offered with 0-5 or 0-10 VDC output in the 24 VAC excitation version. Used in Building Energy Management Systems, these transducers are capable of measuring pressures and fl ows with the accuracy necessary for proper building pressurization and air flow control. The 265 Series very low pressure transducers are available for air pressure ranges as low as 0.25 in. WC full scale up to 100 in. WC full scale. Static accuracy is±1% full scale in normal ambient temperature environments.The units are temperature compensated to less than ±0.033% FS/oF of thermal error over the temperature range of 0oF to +150oF. The Model 265utilizes an improved all stainless steel micro-tig welded sensor. The tensioned stainless steel diaphragm and insulated stainless steel electrode,positioned close tothe diaphragm, form a variable capacitor. Positive pressure moves the diaphragm toward the electrode, increasing the capacitance. A decrease in pressure moves the diaphragm awayfrom the electrode, decreasing the capacitance.The change in capacitance is detected and converted to a linear DC electrical signal by Setra’s unique electronic circuit. The micro-tig welded tension sensor allows up to 10 PSI overpressure range dependent with no damage to the unit.In addition, the sensor parts have thermally matched coeffi cients, which promote improved temperature performance and excellent long-term stability. Unidirectional Pressure Bidirectional Pressure:
Applications:
|
Setra Model 265 Differential Pressure Transducer Range 0- 1000 Pac | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
Features:
More Information:
|
Setra Model 265 Differential Pressure Transducer Range 0- 100 Pac | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Setra Model 265 Differential Pressure Transducer Range 0- 100 Inch | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
More Information:
|
Setra Model 265 Differential Pressure Transducer Range 0- 500 Pac | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
|
Setra Model 265 Differential Pressure Transducer Range 0- 250 Pac | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage:
|
Setra Model 265 Differential Pressure Transducer Range 0- 0.25 Inch | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Supply Voltage
|