Hazardous Area Humidity Temperature Transmitter

Brand Dwyer
Accuracy 90% RH
Response Time 15 Sec
Temperature Range 140 DegreeF
Power Requirements 28 VDC
Output Signal 20 mA
Conduit Connection 1/2 female NPT
Weight 1134 gm
Enclosure Rating IP66
Hazardous Area Humidity Temperature Transmitter

BTT-Shield Temperature Transmitter

Temperature Limits140 DegreeF
Accuracy+-0.5 DegreeC
Response Time100 ms
Process Connection1/2 Inch NPT
Probe Lengths18 Inch
Power Requirements36 VDC
Output Signal20 mA
Weight145 gm
BrandDwyer

BTT-Shield Temperature Transmitter

Dwyer Humidity Temperature Transmitter

BrandDwyer
Accuracy80% RH
Response Time15 Sec
Temperature Range140 DegreeF
Repeatability+-0.1%
Power Requirements35 VDC
Output Signal20 mA
Conduit Connection1/2 Inch NPS
RH SensorCapacitance Polymer
Weight300 Gm


Dwyer Humidity Temperature Transmitter

Relative Humidity and Temperature Transmitter

BrandDwyer
Voltage35 VDC
Accuracy+-2%
Temperature Range122 DegreeF
Response Time2 minutes for 99% step change
Non-Linearity16 PPM
Relative Humidity100%
Pressure Dependence0.13% of Reading Per mm of Hg
Duct Air Velocity Range4000 FPM
Humidity Limits95% RH
Power Consumption2 W
Weight158.8 gm
Model NumberSeries RH


Relative Humidity and Temperature Transmitter

Temperature Transmitter Series TTE Explosion-Proof RTD

Usage/ApplicationTemperature measuring
Model Name/NumberTTE explosion proof
BrandDwyer
Voltage10-35VDC, 21-33 VAC
Accuracy+/-0.1%


Temperature Transmitter Series TTE Explosion-Proof RTD

Series 616KD-LR Differential Pressure Transmitter

Model Name/NumberSeries 616KD-LR-B42-ND1
BrandDwyer
Accuracy+-0.25% FS
Response Time2.5 Hz Sample Rate
Stability+-1% / year FSO
Temperature Limits140 DegreeF
Pressure Limits1 psi
Power Requirements35 VDC
Output Signal20 mA
Weight51 gm
Enclosure RatingIP20


Description: The Series 616KD-LR Differential Pressure Transmitter is designed for simplicity, making it the ideal choice for installers and maintenance professionals. These low range instruments not only alleviate cumbersome turn pots typically found in most transmitters, but eliminate entirely the need to span the instruments during calibration. With single digital push button, both ZERO AND SPAN are calibrated properly, nothing else is required. No additional reference pressure sources or separate calibration devices are necessary.

Series 605 Magnehelic Indicating Transmitter

Model Name/NumberSeries 605
BrandDwyer
Stability+-1% FS/yr
Temperature Limits120 DegreeF
Process Connections1/8 Inch female NPT
Size4 Inch
Weight811 Gm
Power Requirements35 VDC
Output Signal20 mA

Series 605 Magnehelic Indicating Transmitter

628-CB Industrial Pressure Transmitter

BrandDwyer
Accuracy0.25% FS
Response Time300 m sec
Weight283 gm
Process Connections1/4 Inch
Current Consumption38 mA
Power Requirements35 VDC
Temperature Limits200 DegreeF
Model NumberSeries 628-CB


628-CB Industrial Pressure Transmitter

Series DM-2000 Pressure Transmitter

BrandDwyer
Accuracy+-1% FS
Weight136 gm
Process Connections1/8 Inch I.D. tubing.
Display3.5 digit LCD
Current Consumption38 mA
Power Requirements35 VDC
Temperature120 DegreeF
Pressure Limits10 psig
Model NumberSeries DM-2000


Series DM-2000 Pressure Transmitter

Intrinsically Safe Differential Pressure Transmitter

BrandDwyer
Response Time250 ms
Weight1.19 Kg
Enclosure RatingIP66
Process Connections1/8 Inch female NPT
Electrical ConnectionsM-12 4 PIN Connector
Display4 digit LCD
Output Signal20 mA DC
Power Requirements35 VDC
Temperature Limits140 DegreeF
Pressure Limits9 psi


Intrinsically Safe Differential Pressure Transmitter

Series 629C Differential Pressure Transmitter

BrandDwyer
Accuracy+-0.5% FS
Weight286 gm
Process Connections1/4 Inch female or male NPT
Current Consumption28 mA
Power Requirements35 VDC
Temperature Limits200 DegreeF
Display TypeLCD
Model NumberSeries 629C


Series 629C Differential Pressure Transmitter

Series MS Magnesense Differential Pressure Transmitter

BrandDwyer
Accuracy+-1%
Response Time300 ms
Temperature Limits150 DegreeF
Pressure Limits1 psi
Power Requirements35 VDC
Output Signals20 mA
Display4 digit LCD
Weight230 gm
Enclosure RatingNEMA 4X (IP66)
Model NumberSeries MS


Series MS Magnesense Differential Pressure Transmitter

Series MS2 Magnesense II Differential Pressure Transmitter

Usage/ApplicationDP, Air Velocity, Air Flow in HVAC
Model Name/NumberMS2, Magnesense II
BrandDwyer
Voltage10-35VDC, 21-33 VAC
Accuracy+/-1%
Operating Rangeas per model
Depth67 mm
Height88 Dia
Product Weight230g

Series MS2 Magnesense II Differential Pressure Transmitter

Additional Information:

  • Delivery Time: 2 weeks