Air and compatible non combustible, non corrosive gasses
Maximum Pressure
2 psi
Thermal Effect
+/- 0.012% FS/ DegreeF
Output Signal
4-20 mA (option)
Operating
-10 Degree to 140 DegreeF (-23 Degree to 60 DegreeC)
The Series A4 digital differential pressure controller is a patented microprocessor based pressure controller for positive, negative, and differential pressure as well as velocity and flow. The Series A4 differential pressure controller includes (2) 8A SPDT relays and an associated programming menu that allows full configuration of variables such as setpoints, dead band, engineering units, flow coefficients, and more. The programming is done from a user friendly menu on the OLED display or uploaded using an Opti-Link™ programming key. The OLED also displays the exact setpoints or other user defined variables during normal operation. Furthermore, the menu structure can be customized by moving variables to different menu levels to accommodate many applications. Compared to other mechanical products, the Series A4 digital differential pressure controller has a significantly reduced depth, an improved look, and better performance at a similar price.
The Series A2 digital differential pressure gauge is a patented microprocessor based digital pressure gage for positive, negative, and differential measurement designed to be a direct replacement for mechanical gauges. The Series A2 differential pressure gauges utilize an extremely stable piezoresistive sensing technology to give a standard full scale accuracy of 1%. For applications requiring better accuracy, the A2 is also available with 0.5% or 0.25% accuracy. The A2 digital differential pressure gauge also has an optional 4-20 mA output for applications requiring an output signal. The A2 features a bright ½” LED display and process arch, which gives the gauge improved readability and precision. The A2 digital differential pressure gauges also feature 5 user selectable engineering units including in. w.c., mm w.c., cm w.c., kPa, and Pa. The Series A2 offers an improved look, and performance compare to mechanical gauges
Air and compatible non combustible, non corrosive gasses
Maximum Pressure
2 psi
Thermal Effect
+/- 0.012% FS/degF
Output Signal
4-20 mA
Loop Resistance
750 Q max
Response Time
100 ms
The series A3 is a patent pending microprocessor based controller for positive, negative, and differential pressure as well as velocity and flow. The Series A3 includes (2) 8A SPDT relays and an associated software package that allows full configuration of variables such as setpoints, dead band, engineering units, flow coefficients, and more. The programming is done from a user friendly menu on the LCD display or uploaded using an Opti Link™ programming key. The LCD also displays the exact setpoints or other user defined variables during normal operation. Furthermore, the menu structure can be customized by moving variables to different menu levels to accommodate many applications. Compared to other mechanical products, the Series A3 has a significantly reduced depth, an improved look, and better performance at a lower price
Series 2000 Magnehelic Differential Pressure Gauge
Brand
DWYER
Measuring Range
0-50 mm WC
Model Name/Number
Series 2000
Usage/Application
Industrial
Material
Steel
Scale Range
0-100 MM WC
Accuracy
+/-2.5%
Dial Shape
Round
Select The Series 2000 Magnehelic® Gage for a versatile low differential pressure gage with a wide choice of 81 models and 27 options to choose from. Using Dwyer’s simple, frictionless Magnehelic® gage movement, it quickly indicates air or noncorrosive gas pressures–either positive, negative (vacuum) or differential. The design resists shock, vibration, over-pressures and is weatherproof to IP67. Select the -HA High Accuracy Magnehelic® Gage option for an accuracy within 1% of full scale, located below in the Product Configurator. Also included with the –HA option at no extra cost are a mirrored scale overlay and a 6 point calibration certificate.
Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.
Select the Magnehelic gage for high accuracy–guaranteed within 2% of full scale–and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer’s simple, frictionless Magnehelic gage movement, it quickly indicates low air or non-corrosive gas pressures–either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It’s inexpensive, too. The Magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment
Product Highlights:
Bezel provides flange for flush mounting in panel.
Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.
Precision litho-printed scale is accurate and easy to read.
Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.
Pointer stops of molded rubber prevent pointer over-travel without damage.
“Wishbone” assembly provides mounting for helix, helix bearings and pointer shaft.
Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.
Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.
Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.
Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.
Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test.
Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.
Overpressure Protection:
Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the gage interior when over pressure reaches approximately 25 PSIg (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023″ clearance when gage is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180″ of water pressure, medium or high pressure models, or on gages which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gage to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component.
O-ring seal for cover assures pressure integrity of case. Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.
Sensocon USA Series DPT30-R8 Range Differential Pressure Transmitter
Response Time
0.8 – 4.0, jumper selectable
Maximum Pressure
100 in w.c.
Power Supply
24 VDC or VAC, +/- 10%
Enclosure Rating
IP 54/ NEMA 3
Display
3 1/2 Digit LCD Backlit LCD
Media Compatibility
Dry air or non-aggressive gases
The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.
Specification:
Maximum Pressure:100 in w.c.Media compatibility:Dry air or non-aggressive gases Accuracy:Ranges < 0.5 in w.c. = +/- 0.01 in w.c.Ranges ≥ 0.5 in w.c. = +/- 1.5%includes thermal effects, linearity, hysteresis,repeatability, and long term stability.Temperature Ranges:Compensated: 14° to 122°F Operating: 14° to 122°F
Response Time:0.8 – 4.0, jumper selectable Power Supply:24 VDC or VAC, +/- 10%Output:Voltage: 3-wire 0 – 10V or 0 – 5V, jumper selectable Power Consumption: <1.0WMinimum Resistance: 1kΩCurrent: 3-wire4 – 20mAPower Consumption: <1.2WMaximum Load: 500ΩEnclosure Rating:IP 54/ NEMA 3Display:3 ½” Digit LCD Backlit LCD
Sensocon USA Series DPT10-R8 Range Differential Pressure Transmitter
Brand
Sensocon
Response Time
0.8 – 4.0, jumper selectable
Maximum Pressure
100 in w.c.
Power Supply
24 VDC or VAC, +/- 10%
Display
3 1/2 Digit LCD Backlit LCD
Enclosure Rating
IP 54/ NEMA 3
Minimum Resistance
1kOhm
The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.
Specification:
Maximum Pressure:100 in w.c.Media compatibility:Dry air or non-aggressive gasesAccuracy:Ranges < 0.5 in w.c. = +/- 0.01 in w.c.Ranges ≥ 0.5 in w.c. = +/- 1.5%includes thermal effects, linearity, hysteresis,repeatability, and long term stability.Temperature Ranges:Compensated: 14° to 122°FOperating: 14° to 122°F
Backed with immense experience and understanding, we are recognized as one of the most prominent importers and exporters of Transmitter that offers stable and reliable Humidity and Temperature measurement. Be it in international or domestic market, our given Transmitters are cherished and acknowledged over the global platform. The entire array of Transmitter is checked upon a series of norms so as to assure its quality. Besides, we offer the Transmitter in a huge array of stipulations as per the requirements of our patrons.
Technical Information :
The HygroFlex1 series is the latest development in inexpensive HVAC transmitters for relative Humidity and Temperature. The devices are equipped with the tried-and-tested Hygromer® IN-1 sensor and boast unbeatable value for money. The optional ROTRONIC SW21 Software enables you to scale, calibrate and adjust (only Humidity) the Transmitter.
Technical Specification :
General
Transmitter type
2-wire type: HF120 3/4 wire type: HF13x
Supply voltage
12…28 VAC / 15…40 VDC
Current consumption
2-wire type max. 40mA 3/4 wire type with voltage output: < 15 mA with current output: < 55 mA
Parameters
Humidity and/or temperature
Housing material / IP
ABS / IP65
Weight
Wall version type W and A: 140 g Duct version 100 mm type B and D: 140 g Duct version 300 mm type E and F: 200 g Space version type L and S: 90 g
Integrated sensors
Yes
Operating and measurement range
-20…50oC / 0…100 %RH (non-condensing)
CE / EMC compatibility
2004/108/EC
Humidity Measurement
Humidity sensor
ROTRONIC Hygromer® IN-1
Accuracy at 23 oC +5 K
<3 %RH (10…90 %RH)
Long-term stability
<1.5 %RH per year
Response time τ63
30 s (63 % of a jump 35…80 %RH) without ???lter
Temperature Measurement
Sensor
Thermistor
Standard temperature scale
0…50oC or 0…100oF
Accuracy at 23oC +5 K
+ 0.3oK (0…50oC)
Response time
4s
Outputs
Number
Two freely scalable analog outputs
Current
4…20 mA
Voltage
0…1/5/10 VDC
Air Velocity and Temperature Transmitter EE75 Series
Output Value
0 – 10 V or 4 – 20 mA (Adjustable by jumpers)
Accuracy
+/- 0.2m/s 3% mv
Model Number
EE75 Series
Type
Transmitter
Measuring Range
Up to 40 m/s
Working Temperature
40 to 120 deg C
Our Air Velocity Transmitters EE75 Series has a huge demand in the market due to its sturdy construction and high efficiency. These products are widely appreciated among our clients and we provide them in different specifications as per the requirement. Our Air Velocity EE75 Series is extensively used in numerous industries for diverse applications. We also offer them in various customizations to meet the different customer demands. The EE75 Series Air Velocity Transmitters were developed to obtain accurate measuring results over a wide range of Velocities and Temperatures. A high-quality hot film sensor element based on cutting- edge thin film technology ensures maximum sensitivity, even at lowest mass flows. At the same time, the innovative probe design produces reliable measuring results at high flow velocities of up to 40m/s (8000fVmin). The integrated Temperature compensation minimizes the Temperature cross-sensitivity of the EE75 Series which, combined with the robust mechanical design, allows it to be used at process Temperatures between -40 to 120°C(-40 to 248°F).
Other Details:
In addition to Air Velocity and Temperature values, the Transmitter calculates the volumetric flow rate in m3/h or ft3/min. The cross section of the duct needs to be determined for this purpose and the volumetric flow rate can be displayed and directed to one of the analogue outputs. The EE75 Series can be used to measure the velocity of other gases as well, although a correction has to be applied to the unit at the factory.
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
Ambient Temperature – -21 ~140 -6 ~60
Rated Pressure -20 inHg~30 inHg (-68~103KPa)
Overpressure – Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
Process Connections – 1/8″ Female NPT duplicate high and low pressure taps – one pair side and one pair back
Housing – Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
Accuracy – ±2% of full span at 70 (21 (±3% on -0, and ±4% on -00)
Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)
FEATURES
OEM/ODM
There Is No Need To Fill Liquid To Gauge.
The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.