Our Products

Aerosense Differential Pressure Controller Wholesaler

DPI2500-2R-D Aerosense Differential Pressure Controller

 
Usage/ApplicationFan,Blower And Filter Monitoring
BrandAerosense
MaterialABS
Model Name/NumberDPI2500-2R-D
Pressure Range100 / 250 / 1000 / 2500 PA AND +-100 Pa / +-250 / +-300 / +-500 PA
Size89 x 86.5 x 37.1 mm

Aerosense Differential Pressure Controller Aerosense Differential Pressure Controller with field selectable measuring range for building automation in HVAC/R industry.

Features:
  • Unit selectable via menu i.e. PA, kPA, MM WC, IN WC, MBAR
  • Combines up to two relay outputs
  • Optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes)
  • The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects

Applications:
  • Fan, Blower and Filter Monitoring
  • Pressure Monitoring in Clean Rooms
  • Boiler Pressure Monitoring and Alarm
 

DPI2500-2R-D Aerosense Differential Pressure Controller

 
BrandAerosense
Electrical ConnectionScrew Terminals
Model Name/NumberDPI2500-2R-D
Size46.0 W x 14.5 H mm
Weight150 g
Warranty Period6 month
Accuracy+-0.5 % F.S.

DPI2500-2R-D Aerosense Differential Pressure Controller Aerosense Differential Pressure Controller with field selectable measuring range for building automation in HVAC/R industry.

Features:
  • Unit selectable via menu i.e. PA, kPA, MM WC, IN WC, MBAR
  • Combines up to two relay outputs
  • Optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes)
  • The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects

Applications:
  • Fan, Blower and Filter Monitoring
  • Pressure Monitoring in Clean Rooms
  • Boiler Pressure Monitoring and Alarm
 

DPIC500-2R-D Aerosense Differential Pressure Controller

 
BrandAerosense
Case Size89 x 86.5 x 37.1 mm
Control TypeHigh Limit
MaterialABS
Model Name/NumberDPIC500-2R-D
Pressure Range+-100 Pa / +-250 / +-300 / +-500 PA
Warranty6 month
Accuracy+-0.5 % F.S.
Weight150 g
ApplicationsFan,Blower And Filter Monitoring

DPIC500-2R-D Aerosense Differential Pressure Controller Aerosense Differential Pressure Controller with field selectable measuring range for building automation in HVAC/R industry.

Features:
  • Unit selectable via menu i.e. PA, kPA, MM WC, IN WC, MBAR
  • Combines up to two relay outputs
  • Optional Auto-Zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes)
  • The AZ-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects

Applications:
  • Fan, Blower and Filter Monitoring
  • Pressure Monitoring in Clean Rooms
  • Boiler Pressure Monitoring and Alarm
 

Aerosense Carbon Dioxide Transmitter Wholesalers

CDT-100 Aerosense Carbon Dioxide Transmitter

 
Minimum Order Quantity1 Piece
Model NumberCDT-100
Usage/ApplicationDemand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
BrandAerosense
Measurement Range0 to 2000/ 3000/ 5000/ 10000 ppm
Accuracy+-30ppm +-3%
Operating Humidity Range0 to 95% RH
Operating Temperature-10 to 60 deg C
Power24 VDC,AC
Size123x70x43 mm
Storage Temperature-30 to 70 deg C
Storage Temperature for Cold Storage-40 to 70 deg C
Response Time150 seconds
Response Time For Cold Storage70 Seconds
Sampling Interval3 Sec

CDT-100 Aerosense Carbon Dioxide Transmitter Series CDT-100, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range upto 10000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • RS-485 MODBUS output: (4-wired) Modicon MODBUS RTU mode, which follow Modicon Modbus protocol-settable address ID switch
  • Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch

Model No. CDT-100Carbon Dioxide TransmitterCDT-100-LCDCarbon Dioxide Transmitter with displayCDT-100-CSCarbon Dioxide Transmitter for cold storageCDT-100-CS-LCDCarbon Dioxide Transmitter for cold storage with display CDT-100-M Carbon Dioxide Transmitter with MODBUS Communication CDT-100-M-LCD Carbon Dioxide Transmitter with MODBUS Communication & display
 

CDT-100-RLY Aerosense Carbon Dioxide Transmitter

 
Minimum Order Quantity1 Piece
UsageDemand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
ModelSeries CDT-100-RLY
Size123mmx70mmx43mm
Response Time150 seconds
BrandAerosense
Operating Temperature10 to 60 deg C
Storage temperature-30 to 70 deg C

 

CDT-100-RLY Aerosense Carbon Dioxide Transmitter, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range 2000 ppm (5000/10000 ppm) selectable by jumper. It gives analog and Relay output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (6-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • Models available with SPST (Single Pole, Single Throw, normally open) relay output.
  • Re-Calibration function: 10 minutes’ manual recalibration is executable with TRB-100 tool

CDT-300 Aerosense Carbon Dioxide Transmitter

 
Minimum Order Quantity1 Piece
Model NumberSeries CDT-300
Usage/ApplicationDemand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
BrandAerosense
Size123mmx70mmx43mm
Response Time150 Seconds
Operating Temperature-10 to 60 deg C
Operating Humidity range0 to 95% RH
Storage temperature-30 to 70 deg C
Power24 V Dc


CDT-300 Aerosense Carbon Dioxide Transmitter Series CDT-300, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range upto 70000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch

 

Model No.Speci???cations
CDT-300Carbon Dioxide Transmitter
CDT-300-LCDCarbon Dioxide Transmitter with display

Series BTT Temperature Transmitter Wholesalers Delhi India.

Series BTT Temperature Transmitter

 
Minimum Order Quantity12 Number
Usage/ApplicationBuilding Automation System Temperature Monitoring
Model Name/NumberSeries BTT Temperature Transmitter
BrandDwyer USA
Voltage13 to 36 VDC for current models, 13 to 36 VDC or 16 to 28 VAC for voltage models.
Accuracy+-0.5 DegreeC @ 25 DegreeC.
Product Weight5.11 oz, 145 g (duct/immersion); 8.4 oz (238 g) (OSA without radiation shield); 1 lb 7.4 oz (663.4 g
Rated Supply VoltageSeries BTT Temperature Transmitter
Response Time100 ms.
Supply Voltage Limits4 to 20 mA or 0 to 10 VDC (depending on model).
Output Type4 to 20 mA or 0 to 10 VDC (depending on model).
Country of OriginMade in India

SERIES BTT TEMPERATURE TRANSMITTERS

Current or Voltage Output; NEMA 4X Enclosures

The Series BTT Temperature Transmitters offer Transmitter output signals with the same form and fit as our popular TE Thermistor and RTD sensors for building HVAC Applications. Thermowells are required when using immersion models in liquid applications.

NIST CALIBRATION
 Available In Product Configurator.

PRODUCT APPLICATIONS

  • Building Automation System Temperature Monitoring

MODELS & ORDERING

           Model           Description
  • BTT-D04-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 4″ probe
  • BTT-D04-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 4″ probe
  • BTT-D06-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 6″ probe
  • BTT-D06-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 6″ probe
  • BTT-D08-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 8″ probe
  • BTT-D08-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 8″ probe
  • BTT-D12-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 12″ probe
  • BTT-D12-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 12″ probe
  • BTT-D18-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 18″ probe
  • BTT-D18-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 18″ probe
  • BTT-D25-1 Duct Mount Temperature Transmitter with 4 to 20 mA output, 2.5″ probe
  • BTT-D25-2 Duct Mount Temperature Transmitter with 0 to 10 V output, 2.5″ probe


SPECIFICATIONS

  • Temperature Sensor:Pt1000 RTD.
  • Range:-40 to 140°F (-40 to 60°C).
  • Temperature Limits:Operating: -40 to 302°F (-40 to 150°C).
  • Accuracy:±0.5°C @ 25°C.
  • Thermal Effect:±0.01%/°C.
  • Response Time:100 ms.
  • Wetted Materials:All Models:304 SS (probe), polycarbonate (housing);Duct and immersion models: Neoprene (gasket); Outside air models: Nylon (insert), silicone (O-ring).
  • Process Connection:1/2″ NPT (immersion models only).
  • Electrical Connection:Removable terminal block, knocks out for conduit fitting.
  • Conduit Connection:1/2″ NPT.
  • Probe Lengths:2.5 to 18″ (depending on configuration).
  • Power Requirements:13 to 36 VDC for current models, 13 to 36 VDC or 16 to 28 VAC for voltage models.
  • Output Signal:4 to 20 mA or 0 to 10 VDC (depending on model).
  • Enclosure Rating:NEMA 4X (IP66) (immersions models require thermowell).
  • Weight:5.11 oz, 145 g (duct/immersion); 8.4 oz (238 g) (OSA without radiation shield);1 lb 7.4 oz (663.4 g) (OSA with radiation shield).
  • Agency Approvals:CE.

FEATURES

  • Duct, immersion, and outside air models available
  • Radiation shield available for mounting in direct sunlight
  • Transmitter output allows for longer wire runs than standard thermistor sensors

Series BTT Temperature Transmitters Models and Ordering

 
Minimum Order Quantity12 Piece
Usage/ApplicationBuilding Automation System Temperature Monitoring
Model Name/NumberSERIES BTT TEMPERATURE TRANSMITTERS
BrandDwyer USA
Voltage13 to 36 VDC for current models,13 to 36 VDC or 16 to 28 VAC for voltage models.
Accuracy+-0.5 DegreeC @ 25 DegreeC.
Product Weight5.11 oz,145 g (duct/immersion); 8.4 oz (238 g) (OSA without radiation shield); 1 lb 7.4 oz (663.4 g
Response Time100 ms.
Supply Voltage Limits4 to 20 mA or 0 to 10 VDC (depending on model).
Output Type4 to 20 mA or 0 to 10 VDC (depending on model).
Part TypeSERIES BTT TEMPERATURE TRANSMITTERS
Country of OriginMade in India

SERIES BTT TEMPERATURE TRANSMITTERS MODELS & ORDERING

Duct Mount Temperature Transmitter

  • BTT-D04-1-With 4 to 20 mA output,4″ probe
  • BTT-D04-2-With 0 to 10 V output,4″ probe 
  • BTT-D06-1-With 4 to 20 mA output,6″ probe
  • BTT-D06-2-With 0 to 10 V output,6″ probe 
  • BTT-D08-1-With 4 to 20 mA output,8″ probe 
  • BTT-D08-2-With 0 to 10 V output,8″ probe 
  • BTT-D12-1-With 4 to 20 mA output,12″ probe 
  • BTT-D12-2-With 0 to 10 V output,12″ probe 
  • BTT-D18-1-With 4 to 20 mA output,18″ probe 
  • BTT-D18-2-With 0 to 10 V output,18″ probe 
  • BTT-D25-1-With 4 to 20 mA output,2.5″ probe 
  • BTT-D25-2-With 0 to 10 V output,2.5″ probe

Immersion Temperature Transmitter

  • BTT-I04-1-With 4 to 20 mA output,-40 to 60 C temperature range,4″ probe
  • BTT-I04-2-With 0 to 10 V output,-40 to 60 C temperature range,4″ probe
  • BTT-I04-5-With 4 to 20 mA output,0 to 100 C temperature range,4″ probe
  • BTT-I04-6-With 0 to 10 V output,0 to 100 C temperature range, 4″ probe
  • BTT-I06-1-With 4 to 20 mA output,-40 to 60 C temperature range,6″ probe
  • BTT-I06-2-With 0 to 10 V output,-40 to 60 C temperature range,6″ probe
  • BTT-I06-5-With 4 to 20 mA output,0 to 100 C temperature range,6″ probe
  • BTT-I06-6-With 0 to 10 V output,0 to 100 C temperature range,6″ probe
  • BTT-I08-1-With 4 to 20 mA output,-40 to 60 C temperature range,8″ probe
  • BTT-I08-2-With 0 to 10 V output,-40 to 60 C temperature range,8″ probe
  • BTT-I08-5-With 4 to 20 mA output,0 to 100 C temperature range,8″ probe
  • BTT-I08-6-With 0 to 10 V output,0 to 100 C temperature range,8″ probe
  • BTT-I12-1-With 4 to 20 mA output,-40 to 60 C temperature range,12″ probe
  • BTT-I12-2-With 0 to 10 V output,-40 to 60 C temperature range,12″ probe
  • BTT-I12-5-With 4 to 20 mA output,0 to 100 C temperature range,12″ probe
  • BTT-I12-6-With 0 to 10 V output,0 to 100 C temperature range,12″ probe
  • BTT-I25-1-With 4 to 20 mA output,-40 to 60 C temperature range,2.5″ probe
  • BTT-I25-2-With 0 to 10 V output,-40 to 60 C temperature range,2.5″ probe
  • BTT-I25-5-With 4 to 20 mA output,0 to 100 C temperature range,2.5″ probe
  • BTT-I25-6-With 0 to 10 V output,0 to 100 C temperature range,2.5″ probe

Outside Air Temperature Transmitter

  • BTT-O25-1-Outside Air Temperature Transmitter with 4 to 20 mA Output
  • BTT-O25-2-Outside Air Temperature Transmitter with 0 to 10 V Output 
  • BTT-R25-1-Outside Air Temperature Transmitter with 4 to 20 mA Output with solar radiation shield
  • BTT-R25-2- Outside Air Temperature Transmitter with 0 to 10 V Output with solar radiation shield

European Wall Mount Temperature Transmitter (BTT-E/N)

  • BTT-E00-3-European wall mount temperature transmitter with 4 to 20 mA output
  • BTT-E00-4-European wall mount temperature transmitter with 0 to 10 VDC output
  • BTT-N00-3-North American wall mount temperature transmitter with 4 to 20 mA output
  • BTT-N00-4-North American wall mount temperature transmitter with 0 to 10 VDC output
 

Dwyer BTT-D04-1 Duct Mount Temperature Sensors

 
Minimum Order Quantity12 Piece
Usage/ApplicationBuilding Automation System Temperature Monitoring
Model Name/NumberDwyer BTT-D04-1
BrandDwyer USA
Voltage13 to 36 VDC
Accuracy+-0.5 DegreeC @ 25 DegreeC.
Operating RangeDwyer BTT-D04-1
Product Weight5.11 oz (145 g)
Protection TypeDwyer BTT-D04-1 Duct Mount Temperature Sensors
Rated Supply Voltage13 to 36 VDC
Response Time100 msec
Output Type4 to 20 mA
Part TypeDwyer BTT-D04-1 Duct Mount Temperature Sensors
Country of OriginMade in India

Dwyer BTT-D04-1 Duct Mount Temperature Sensors


  • Output Signal: 4 – 20 mA, 
  • Probe Length: 4″
  • Brand Dwyer Part # BTT-D04-1
  • Model # BTT Series
  • Condition Brand New

Dwyer, BTT-D04-1, BTT Series 4 – 20 mA Duct Mount Temperature Transmitter with 4″ Probe

The Series BTT Temperature Transmitter Can Be Used For The Following Applications: Monitoring The Temperature Inside Air Ducts For HVAC, Transmitting Temperature Inside Water Lines For Chillers

Features

  • Transmitter Output Allows For Longer Wire Runs Than Standard Thermistor Sensors

Applications
  • Building Automation System Temperature Monitoring

Notifications

  • Item Is Non-Returnable Unless Defective

Declaration:
  • This Product Can Be Customized To Your Needs (Voltage,Ranges,Sizes,Additional Documents,Etc.). Please Contact Us Or Add To Quote If Any Specific Requirements Are Needed.

Technical Details

  • Temperature Sensor:Pt1000 RTD
  • Range:-40 to 140 °F (-40 to 60 °C)
  • Temperature Limits:-40 to 140 °F (-40 to 60 °C)
  • Accuracy:±0.5°C @ 25°C.
  • Response Time:100 msec
  • Wetted Materials:304 SS (probe), polycarbonate (housing), Neoprene (gasket)
  • Electrical Connection:Removable terminal block, knocks out for conduit fitting
  • Conduit Connection:1/2″ NPT
  • Probe Length:4″
  • Power Requirements:13 to 36 VDC
  • Output Signal:4 to 20 mA
  • Enclosure Rating:NEMA 4X (IP66)
  • Weight:5.11 oz (145 g)
  • Agency Approvals:CE
 

Temperature Transmitters Wholesale India

Universal Type Temperature Transmitter

 
Minimum Order Quantity12 Piece
Usage/ApplicationConverts all type of Thermocouple, RTD, Ohms, mV into 4 to 20mA analogue output
Model Name/NumberGALAXY
BrandGALAXY
Rated Supply Voltage10 to 32 VDC
Supply Voltage Limits10 to 32 VDC
Output Type2 Wire, 4 to 20mA
Part TypeUniversal Type Temperature Transmitter
Country of OriginMade in India
Input ValueAll type of Thermocouple, RTDs, Ohms, mV
Programming & CalibrationUser friendly software and a USB Calibrator
MountingHead Mount

Universal Type Temperature Transmitter

PC Programmable Head Mount Temperture Transmitter Which Converts All Tc, RTD, Ohms Mv Into a Scalable Analogue Signal Of 4 to 20ma.

Performance

  • 2-Wire Technology, 4 to 20ma Analogue Output.
  • High Accuracy In Total Ambient Temperature Range.
  • Internal Cold Junction Compensation.
  • Wide Voltage Supply Range.
  • Customer Specific Measurement Range Setting Or Expanded Setup.
  • Simple And User Friendly Software.
  • USB Communication.

INPUT

  • Type : TC, RTD, Ohms, mV
  • Measurement Ranges : -200 to 850°c
  • Connection Type : 3-Wire Connection

OUTPUT

  • Output Signal : 2 Wire, 4 to 20ma Scalable Analogue Signal Output

  • Current Alarm Output : 3. 6ma or 22ma When Sensor Damage Or Break.

 
TECHNICAL SPECIFICATIONS

  • Damp : 0-32s
  • Current Limit : ≤ 22ma
  • Saturation Current : Low 3. 8ma ; High 20. 6ma
  • Response Time : ≤ 0. 8s
  • Data Refresh Rate : 4 Times/Sec
  • Accuracy : ± 0. 1%
  • Stability :0. 01 ??c
  • Power Supply : 10 to 32 VDC 

Temperature Transmitters

 
Minimum Order Quantity12 Number
Usage/ApplicationConverts RTD & Thermocouple Input into linear scalable 4 to 20mA.
Model Name/NumberTR 213
BrandGALAXY
Voltage24 VDC
Rated Supply Voltage24 VDC
Output Type2 Wire,4 to 20mA
Country of OriginMade in India
Input ValueUniversal All type of RTD & Thermocouple Input

Temperature Transmitters

TT 210 is a Head Mount Non isolated universal temperature transmitter for resistance thermometers (RTD), thermocouples (TC), resistance & voltage (mV) which converts all these data signals into scalable 4 to 20mA analogue output signal.
 
This is a user programmable temperature transmitter which can be programmed for input signal from ANDROID SMART PHONE or LAPTOP  via data cable & user friendly operating software.
 
Performance Features:


  • 2 wire technology 4 to 20 mA analogue output.
  • High accuracy in total ambient temperature range.
  • An internal temperature sensor for active temperature compensation.
  • Wide voltage supply range.
  • Customer specific measurement range setting.
  • Simple & user friendly software
  • USB Communication


Technical Data

  • Input RTD, TC, OHM, mV
  • Output 4 to 20 mA
  • Supply voltage 7.5 to 45 VDC
  • Cold junction Internal
  • Influence of ambient Negligible
  • Load influence Negligible
  • Power supply influence Negligible
  • Resolution 0.3 uA
  • Installation Sensor head from B
  • Operation PC – programmable
  • Weight Approx. 35 GMS
  • Dimensions 44 MM × 22. 5 MM (Φ × H)
 

RTD PT 100 Temperature Transmitter

 
Minimum Order Quantity12 Piece
Usage/ApplicationUse for converting RTD Signal into scalable analog Input signal 4 to 20mA
Model Name/NumberRTD PT 100
BrandGALAXY
Voltage10 to 32 VDC
Accuracy+- 0.1%
Protection TypeRTD PT 100 Temperature Transmitter
Output Type4 to 20mA
Part TypeRTD PT 100 Temperature Transmitter
Country of OriginMade in India
ProgrammingCan be programmed with user freindly software & USB

RTD PT 100 Temperature Transmitter

PC Programmable Head Mount Temperture Transmitter Which Converts All Tc, RTD, Ohms Mv Into a Scalable Analogue Signal Of 4 to 20ma.

Performance

  • 2-Wire Technology, 4 to 20ma Analogue Output.
  • High Accuracy In Total Ambient Temperature Range.
  • Internal Cold Junction Compensation.
  • Wide Voltage Supply Range.
  • Customer Specific Measurement Range Setting Or Expanded Setup.
  • Simple And User Friendly Software.
  • USB Communication.

INPUT

  • Type : TC, RTD, Ohms, mV ( RTD PT 100 )
  • Measurement Ranges : -200 to 850°c
  • Connection Type : 3-Wire Connection

OUTPUT

  • Output Signal : 2 Wire, 4 to 20ma Scalable Analogue Signal Output

  • Current Alarm Output : 3. 6ma or 22ma When Sensor Damage Or Break.

 
TECHNICAL SPECIFICATIONS

  • Damp : 0-32s
  • Current Limit : ≤ 22ma
  • Saturation Current : Low 3. 8ma ; High 20. 6ma
  • Response Time : ≤ 0. 8s
  • Data Refresh Rate : 4 Times/Sec
  • Accuracy : ± 0. 1%
  • Stability :0. 01 ??c
  • Power Supply : 10 to 32 VDC 

Dwyer Instruments Distributors in India

2000-60PA-ASF Dwyer Instruments

 
Minimum Order Quantity12 Number
BrandDwyer USA
Measuring Range0-60 PA
Model Number2000-60PA-ASF
Usage/ApplicationIndustrial
Weight1 lb 2 oz (510 g),MP & HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Agency ApprovalRoHS
Process Connections1/8″ female NPT
Temperature Limits20 to 140 deg F (-6.67 to 60 deg C)

2000-60PA-ASF Dwyer Instruments Select the Magnehelic gage for high accuracy–guaranteed within 2% of full scale–and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer’s simple, frictionless Magnehelic gage movement, it quickly indicates low air or non-corrosive gas pressures–either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It’s inexpensive, too. The Magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment

Product Highlights

  • Bezel provides flange for flush mounting in panel.
  • Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.
  • Precision litho-printed scale is accurate and easy to read.
  • Red tipped pointer of heat treated
  • aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • “Wishbone” assembly provides mounting for helix, helix bearings and pointer shaft.
  • Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.
  • Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.
  • Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.
  • Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.
  • Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
  • Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test.
  • Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.
 

Overpressure Protection:
Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the gage interior when over pressure reaches approximately 25 PSIg (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023″ clearance when gage is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180″ of water pressure, medium or high pressure models, or on gages which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gage to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component. O-ring seal for cover assures pressure integrity of case. Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

  • Range 0-60 Pa
  • Adjustable set flag
 

Series TDFS Thermal Dispersion Flow Switch

 
Minimum Order Quantity1 No
BrandDwyer USA
Agency ApprovalsCE
Housing Materials316 SS, 416 SS, Polycarbonate, Neoprene, And Acrylated Urethane
Enclosure RatingNEMA 4X (IP65)
Process Connection1/2″ NPT male
Electrical Connection4 conductor 22 AWG, 6′ (1.83 m) long with cable gland
Current ConsumptionAverage:93 mA, Peak: 300 mA
Power Requirement9 to 24 VDC
Response TimeApproximately 8 s
Pressure Limits300 psig (20.67 bar)
Wetted Materials316 SS, Polysulfone, and FKM
Setpoint Range0.5 to 10 ft/s (0.15 to 3.0 m/s)
Repeatability0.07 ft/s +3% of setpoint
Switching Current400 mA, derate 5 mA/ deg C above 23 deg C

Series TDFS Thermal Dispersion Flow Switch
  • OLD Modal TDFS-1-P-06 
  • NEW Modal TDFS-2-P-06

The Series TDFS2 Thermal Dispersion Flow Switch is a thermal flow switch that indicates whether the flow rate is above or below a user set flow rate. The unit incorporates two LED status indicators providing visual switch indication. The set flow rate (setpoint) is field adjustable and the unit has both NO and NC NPN outputs. See Figure 1 on catalog page for output and LED actions on change of flow

Product Applications:
  • Boiler Flow Proving
  • Hot Water Heaters
  • Chillers
  • Liquid Transfer Systems

Model – TDFS2-1-P-06
Thermal Dispersion Flow Switch, 316SS, 1/2″ NPT Process Connection, 6′ of Cable With Cable Gland.
 

TDFS-1-P-06 Thermal Dispersion Flow Switch

 
Minimum Order Quantity1 Number
BrandDwyer USA
Model Name/NumberTDFS-1-P-06
Material316 SS,416 SS,Polycarbonate,Neoprene,And Acrylated Urethane.
Agency ApprovalsCE
Switch Type1 NO NPN,1 NC NPN
Enclosure RatingNEMA 4X (IP65)
Process Connection1/2″ NPT male
Electrical Connection4 conductor 22 AWG,6′ (1.83 m) long with cable gland
Current ConsumptionAverage:93 mA,Peak: 300 mA
Switching Current400 mA,derate 5 mA/ deg C above 23 deg C
Power Requirement9 to 24 VDC
Response TimeApproximately 8 s
Pressure Limits300 psig (20.67 bar)
Typical Deadband0.1 ft/s +15% of setpoint
Repeatability0.07 ft/s +3% of setpoint
Setpoint Range0.5 to 10 ft/s (0.15 to 3.0 m/s)
Wetted Materials316 SS,Polysulfone,and FKM

TDFS-1-P-06 Thermal Dispersion Flow Switch
  • OLD Modal TDFS-1-P-06 
  • NEW Modal TDFS-2-P-06 

The Series TDFS2 Thermal Dispersion Flow Switch is a thermal flow switch that indicates whether the flow rate is above or below a user set flow rate. The unit incorporates two LED status indicators providing visual switch indication. The set flow rate (setpoint) is field adjustable and the unit has both NO and NC NPN outputs. See Figure 1 on catalog page for output and LED actions on change of flow

Product Applications:
  • Boiler Flow Proving
  • Hot Water Heaters
  • Chillers
  • Liquid Transfer Systems

Model – TDFS2-1-P-06
  • Thermal Dispersion Flow Switch, 316SS, 1/2″ NPT Process Connection, 6′ of Cable With Cable Gland.
 

Galaxy PCM313 Pressure Transmitter Wholesalers Delhi India

Galaxy Pressure Transmitter PCM313 Range 0 To 250 MBAR

Minimum Order Quantity12 Piece
Usage/ApplicationProcess Control,Aerospace,Automotive And Medical Equipment,Pipeline System
Model Name/NumberPCM313 Range 0 To 250 MBAR
BrandGalaxy
Voltage12-36VDC
Accuracy0.5%FS
Operating Range0 To 250 MBAR
Product Weight100-150g
Protection TypeGalaxy Pressure Transmitter PCM313 Range 0 To 250 MBAR
Rated Supply Voltage12-36VDC
Supply Voltage Limits12-36VDC
Output Type4 to 20mA
Part TypeGalaxy Pressure Transmitter PCM313 Range 0 To 250 MBAR
Country of OriginMade in India

Galaxy Pressure Transmitter PCM313 Range 0 To 250 MBAR

PCM313 Pressure Transmitter

Characteristic

  • SS316 Diaphragm Structure 

  • High Accuracy,Full Stainless Steel Construction 

  • Small,Lightweight 

  • Superior Long-Term Stability 

  • Easy To Install And Use 

  • Pressure Measurements In The Range Large Absolute Pressure,Gauge Pressure,The Shield Gauge Pressure Side       

   Information Available 

  • Dust-Proof,Shock-Resistance 

 
Applications

  • Process Control 

  • Aerospace 

  • Automotive And Medical Equipment 

  • Pipeline System


Performance Parameters

  • Pressure Range--100 kPa… 0 to 35 kPa… 25 MPa

  • Pressure Reference-Gauge Pressure,Absolute Pressure,Shield Gauge Pressure

  • Accuracy-0.5%FS

  • Hysteresis-0.1%FS

  • Repeatability-0.1%FS

  • Temperature Drift-35kPa: ±3%FS (0 to 60???) Other ranges: ±1.5%FS (-10 to 70???)

  • Response Time-≤10ms???up to 90%FS???

  • Breaking Pressure-See Pressure Range Selection

  • Life Span-≥1×106 Pressure Cycles

  • Operating Temperature Range–20 ∼ 85???

  • Medium Temperature Range--30 ~ 105??? 

  • Storage Temperature Range–40 ∼ 125???

  • EMC-Immunity:IEC 61000-6-2,Radiation:IEC 61000-6-3

  • Insulation Resistance-≥100MΩ/250VDC

  • My Vibration-Sine curve: 20 g, 25 Hz to 2 kHz; IEC 60068-2-6,Random: 7.5 grms, 5 Hz to 1 kHz; IEC 60068-2-64

  • My Shock-Shock: 200g/1ms; IEC 60068-2-27,Free???1m???IEC 60068-2-32

  • Protection-IP65

  • Bibliography-IEC 61000-4-5 level 1

  • My Voltage-500V/AC 1min

  • Static-IEC 61000-4-2 2level

  • Media Compatibility-All Media Compatible With 316L Stainless Steel

  • Hexagon-Sandblasting HEX27

  • Explosion-Proof Rating

  • Intrinsically Safe Explosion-Proof Exia???CT6

  • Weight-100 ~ 150g



Output And Supply Power

  • Code- B1 – Customized

  • Print – 4 to 20mA, –

  • Supply Power – 12 ???36VDC – 

Galaxy Pressure Transmitter PCM313 Range 0 To 500 MBAR

 
Minimum Order Quantity12 Piece
Usage/ApplicationProcess Control,Aerospace,Automotive And Medical Equipment,Pipeline System
Model Name/NumberPCM313
BrandGalaxy
Voltage12-36VDC
Accuracy0.5%FS
Product Weight100-150g
Protection TypeGalaxy Pressure Transmitter PCM313 Range 0 To 500 MBAR
Rated Supply Voltage12-36VDC
Supply Voltage Limits12-36VDC
Output Type4 to 20mA
Part TypeGalaxy Pressure Transmitter PCM313 Range 0 To 500 MBAR
Country of OriginMade in India

Galaxy Pressure Transmitter PCM313 Range 0 To 500 MBAR

PCM313PRESSURE TRANSMITTER

Product Overview

GALAXY economic pressure transmitter adopts diffused silicon   pressure sensor as pressure sensing element.Through internal ASIC,the millivolt signal of sensor is transmitted into standard  current signal.GALAXY can be directly connected with computer interface card,control instruments,intelligent meters or PLC etc.conveniently.Long-distance  transmission can use current  output.GALAXY features with small size,light weight,all stainless steelsealing structure and ability to work in corrosive  environments.The product is easy to install and has extremely high vibration and shock resistance.GALAXY is widely used in processcontrol,aviation,aerospace,automobile,medical  equipment,HVAC and otherfields

Notes:
  • Do not misusedocumentation
  • The information presented in this product sheet is forreference only.Do not use this document as a product installationguide
  • Complete installation,operation,and maintenance informationis provided in the instructions of theproduct.
  • Misuse of the product may cause danger or personalinjury
Features
  • SS316L diaphragmstructure
  • High accuracy,all Stainless Steel Structure
  • Small Size and lightweight
  • Strong anti-interference,good long-Termstability
  • Diversified formal structures,easy installation anduse
  • Wide  pressure  range,can measure the absolute pressure, gauge pressure and sealed gaugepressure
  • Anti-vibration,Shockresistance
  • Zero,full spanadjustable
Applications and industries
  • Processcontrol
  • Aerospace
  • Automobile and medicalequipment
  • Pipelinesystem
Notes:
  • Do not touch the diaphragm with hard objects,which may  cause damage to the diaphragm
  • Please read the Instruction Manual of the product carefully before installation and check the relevant information of theproduct
  • Strictly follow the wiring method  for wiring, otherwise  it may cause product damage or other potentialfaults
  • Misuse of the product may cause dangerorpersonal injury
Performance Parameters
  • Pressure Range –100kPa…0~35kPa…100MPa
  • Pressure Reference-Gauge pressure,Absolute pressure, Sealed Gauge Pressure
  • Accuracy-0.5%FS
  • Hysteresis-0.1%FS
  • Repeatability-0.1%FS
  • Temperature Drift-35kPa:±2%FS(0°C-60°C 
  • Other Ranges:±1.5%FS(-20°C-85°C
Performance Parameters (cont.)
  • Response Time-≤1ms (Up to 90%FS)
  • Overpressure-Refer to Table for Pressure Range Selection
  • Service Life-≥1×106 Pressure Cycles
  • Ambient Temperature-20°C-85°C
  • Medium Temp.-30°C-105°C
  • Storage Temp.-40°C-125°C
  • EMC-Immunity: IEC 61000-6-2,Radiation:IEC 61000-6-3
  • Insulation Resistance-100MΩ/500VDC(200MΩ/250VDC)
  • Vibration Resistance-Sine curve:20g,25Hz-2kHz;IEC 60068-2-6,Random:7.5grms,5Hz-1kHz;IEC 60068-2-64
  • Shock Resistance-Shock:200g/1ms;IEC 60068-2-27,Free Falling Body:1m;IEC 60068-2-32
  • Protection Grade-IP65
  • Surge-IEC 61000-4-5 3 level
  • Voltage ResistanceCurrent Output-500V/AC 1min Voltage Output-250V/AC 1min
  • Static Electricity-IEC 61000-4-2 4 level
  • Hexagon-HEX27
  • Ex-Proof Grade-Intrinsically safe explosion-proof ExiaIICT6 (only for 4-20mA)
  • Net Weight-150-180g

Galaxy Pressure Transmitter PCM313 Range 0 To 100 Mbar

 
Minimum Order Quantity12 Piece
Usage/ApplicationProcess Control,Aerospace,Automotive And Medical Equipment,Pipeline System
Model Name/NumberPCM313
BrandGalaxy
Voltage12-36VDC
Accuracy0.5%FS
Product Weight100-150g
Protection TypeGalaxy Pressure Transmitter PCM313 Range 0 To 100 Mbar
Rated Supply Voltage12-36VDC
Supply Voltage Limits12-36VDC
Output Type4 to 20mA
Part TypeGalaxy Pressure Transmitter PCM313 Range 0 To 100 Mbar
Country of OriginMade in India

Galaxy Pressure Transmitter PCM313 Range 0 To 100 Mbar

PCM313PRESSURE TRANSMITTER

Product Overview

GALAXY economic pressure transmitter adopts diffused silicon   pressure sensor as pressure sensing element.Through internal ASIC,the millivolt signal of sensor is transmitted into standard  current signal.GALAXY can be directly connected with computer interface card,control instruments,intelligent meters or PLC etc.conveniently.Long-distance  transmission can use current  output.GALAXY features with small size,light weight,all stainless steelsealing structure and ability to work in corrosive  environments.The product is easy to install and has extremely high vibration and shock resistance.GALAXY is widely used in processcontrol,aviation,aerospace,automobile,medical  equipment,HVAC and otherfields

Notes:
  • Do not misusedocumentation
  • The information presented in this product sheet is forreference only.Do not use this document as a product installationguide
  • Complete installation,operation,and maintenance informationis provided in the instructions of theproduct.
  • Misuse of the product may cause danger or personalinjury
Features
  • SS316L diaphragmstructure
  • High accuracy,all Stainless Steel Structure
  • Small Size and lightweight
  • Strong anti-interference,good long-Termstability
  • Diversified formal structures,easy installation anduse
  • Wide  pressure  range,can measure the absolute pressure, gauge pressure and sealed gaugepressure
  • Anti-vibration,Shockresistance
  • Zero,full spanadjustable
Applications and industries
  • Processcontrol
  • Aerospace
  • Automobile and medicalequipment
  • Pipelinesystem
Notes:
  • Do not touch the diaphragm with hard objects,which may  cause damage to the diaphragm
  • Please read the Instruction Manual of the product carefully before installation and check the relevant information of theproduct
  • Strictly follow the wiring method  for wiring, otherwise  it may cause product damage or other potentialfaults
  • Misuse of the product may cause dangerorpersonal injury
Performance Parameters
  • Pressure Range –100kPa…0~35kPa…100MPa
  • Pressure Reference-Gauge pressure,Absolute pressure, Sealed Gauge Pressure
  • Accuracy-0.5%FS
  • Hysteresis-0.1%FS
  • Repeatability-0.1%FS
  • Temperature Drift-35kPa:±2%FS(0°C-60°C 
  • Other Ranges:±1.5%FS(-20°C-85°C
Performance Parameters (cont.)
  • Response Time-≤1ms (Up to 90%FS)
  • Overpressure-Refer to Table for Pressure Range Selection
  • Service Life-≥1×106 Pressure Cycles
  • Ambient Temperature-20°C-85°C
  • Medium Temp.-30°C-105°C
  • Storage Temp.-40°C-125°C
  • EMC-Immunity: IEC 61000-6-2,Radiation:IEC 61000-6-3
  • Insulation Resistance-100MΩ/500VDC(200MΩ/250VDC)
  • Vibration Resistance-Sine curve:20g,25Hz-2kHz;IEC 60068-2-6,Random:7.5grms,5Hz-1kHz;IEC 60068-2-64
  • Shock Resistance-Shock:200g/1ms;IEC 60068-2-27,Free Falling Body:1m;IEC 60068-2-32
  • Protection Grade-IP65
  • Surge-IEC 61000-4-5 3 level
  • Voltage ResistanceCurrent Output-500V/AC 1min Voltage Output-250V/AC 1min
  • Static Electricity-IEC 61000-4-2 4 level
  • Hexagon-HEX27
  • Ex-Proof Grade-Intrinsically safe explosion-proof ExiaIICT6 (only for 4-20mA)
  • Net Weight-150-180g
 

Aerosense Mini Digital Differential Pressure Gauge-Controller-Transmitter Wholesaler India

Aerosense Mini Digital Differential Pressure/Gauge/Controller/Transmitter

 
 
Minimum Order Quantity12 No
BrandAerosense Singapore
Measuring RangeSERIES MD
Usage/ApplicationIndustrial
ConnectionNew
ColorBlack
Country of OriginMade in India

Aerosense Mini Digital Differential Pressure/Gauge/Controller/Transmitter
 

Aerosense Mini Digital Differential Pressure Gauge

 
 
Minimum Order Quantity12 No
BrandAerosense Singapore
Usage/ApplicationIndustrial
ConnectionNew
Display TypeYAS
TypeAerosense Mini Digital Differential Pressure Gauge
ColorBlack
Country of OriginMade in India

Aerosense Mini Digital Differential Pressure Gauge
 

Aerosense Mini Digital Differential Pressure Controller

 
 
Minimum Order Quantity12 No
BrandAerosense Singapore
Model Name/NumberSERIES MD
Usage/ApplicationIndustrial
ConnectionNew
Display TypeYAS
ColorBlack
Country of OriginMade in India

Aerosense Mini Digital Differential Pressure Controller
 

Aerosense Mini Digital Differential Pressure Transmitter

 
 
Minimum Order Quantity12 No
Usage/ApplicationIndustrial
Model Name/NumberSERIES MD
BrandAerosense Singapore
Country of OriginMade in India

Aerosense Mini Digital Differential Pressure Transmitter

Series TDS Thermal Dispersion Flow Switch Wholesaler India

Series TDS Thermal Dispersion Flow Switch

 
 
Mounting OptionsAny orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe s
Measuring RangeRange 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
BrandDWYER
Usage/ApplicationLiquids.
Model Name/NumberSeries TDS
Material/BodyPolypropylene/PPS or Polyvinylidene Fluoride.
Process Temperature32 to 140 DegreeF (0 to 60 DegreeC).

Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.

Models & Ordering:
ModelDescription
TDS112Thermal dispersion flow switch, PP/PPS wetted parts, 3.0″ (7.6 cm) length.
TDS122Thermal dispersion flow switch, PP/PPS wetted parts, 4.5″ (11.4 cm) length.
TDS212Thermal dispersion flow switch, PVDF wetted parts, 3.0″ (7.6 cm) length.
TDS222Thermal dispersion flow switch, PVDF wetted parts, 4.5″ (11.4 cm) length.

Specifications:
  • Service: Liquids.
  • Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
  • Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
  • Temperature Limits: 32 to 140°F (0 to 60°C).
  • Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
  • Repeatability: ±5% of setpoint.
  • Switch Type: SPDT.
  • Electrical Rating: 60 VAC/60 VDC @ 1 A.
  • Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
  • Process Connections: 3/4″ male NPT.
  • Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
  • Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
  • Setpoint Drift: 0.5% of setpoint.
  • Response Time: 1-10 seconds.
  • Viscosity Range: 1 to 200 centipoise.
  • Supply Voltage: 12 to 36 VDC.
  • Consumption: 50 mA (nominal).
  • Indication: LED for flow status.
  • Weight: 3 oz (94 g).
  • Agency Approvals: CE.
 

Dwyer TDS112 Thermal Dispersion Flow Switch

 
 
BrandDwyer
Model Name/NumberTDS 112
Connection Type3/4″ male NPT.
Weight3 oz (94 g)
Setpoint Drift0.5% of setpoint
Response Time1-10 sec
Viscosity Range1 to 200 centipoise

Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.

Models & Ordering:
ModelDescription
TDS112Thermal dispersion flow switch, PP/PPS wetted parts, 3.0″ (7.6 cm) length.
TDS122Thermal dispersion flow switch, PP/PPS wetted parts, 4.5″ (11.4 cm) length.
TDS212Thermal dispersion flow switch, PVDF wetted parts, 3.0″ (7.6 cm) length.
TDS222Thermal dispersion flow switch, PVDF wetted parts, 4.5″ (11.4 cm) length.

Specifications:
  • Service: Liquids.
  • Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
  • Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
  • Temperature Limits: 32 to 140°F (0 to 60°C).
  • Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
  • Repeatability: ±5% of setpoint.
  • Switch Type: SPDT.
  • Electrical Rating: 60 VAC/60 VDC @ 1 A.
  • Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
  • Process Connections: 3/4″ male NPT.
  • Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
  • Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
  • Setpoint Drift: 0.5% of setpoint.
  • Response Time: 1-10 seconds.
  • Viscosity Range: 1 to 200 centipoise.
  • Supply Voltage: 12 to 36 VDC.
  • Consumption: 50 mA (nominal).
  • Indication: LED for flow status.
  • Weight: 3 oz (94 g).
  • Agency Approvals: CE.
 

Dwyer TDS122 Thermal Dispersion Flow Switch

 
 
BrandDWYER
Weight3 oz (94 g)
Consumption50 mA (nominal)
Supply Voltage12 to 36 VDC
Viscosity Range1 to 200 centipoise
Response Time1-10 sec

Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.

Models & Ordering:
ModelDescription
TDS112Thermal dispersion flow switch, PP/PPS wetted parts, 3.0″ (7.6 cm) length.
TDS122Thermal dispersion flow switch, PP/PPS wetted parts, 4.5″ (11.4 cm) length.
TDS212Thermal dispersion flow switch, PVDF wetted parts, 3.0″ (7.6 cm) length.
TDS222Thermal dispersion flow switch, PVDF wetted parts, 4.5″ (11.4 cm) length.

Specifications:
  • Service: Liquids.
  • Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
  • Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
  • Temperature Limits: 32 to 140°F (0 to 60°C).
  • Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
  • Repeatability: ±5% of setpoint.
  • Switch Type: SPDT.
  • Electrical Rating: 60 VAC/60 VDC @ 1 A.
  • Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
  • Process Connections: 3/4″ male NPT.
  • Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
  • Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
  • Setpoint Drift: 0.5% of setpoint.
  • Response Time: 1-10 seconds.
  • Viscosity Range: 1 to 200 centipoise.
  • Supply Voltage: 12 to 36 VDC.
  • Consumption: 50 mA (nominal).
  • Indication: LED for flow status.
  • Weight: 3 oz (94 g).
  • Agency Approvals: CE.
 

Dwyer TDS212 Thermal Dispersion Flow Switch

 
 
BrandDWYER
Model Name/NumberTDS212
Connection Type3/4″ male NPT.
Setpoint Drift0.5% of setpoint
Response Time1-10 sec
Viscosity Range1 to 200 centipoise
Supply Voltage12 to 36 VDC

Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.

Models & Ordering:
ModelDescription
TDS112Thermal dispersion flow switch, PP/PPS wetted parts, 3.0″ (7.6 cm) length.
TDS122Thermal dispersion flow switch, PP/PPS wetted parts, 4.5″ (11.4 cm) length.
TDS212Thermal dispersion flow switch, PVDF wetted parts, 3.0″ (7.6 cm) length.
TDS222Thermal dispersion flow switch, PVDF wetted parts, 4.5″ (11.4 cm) length.

Specifications:
  • Service: Liquids.
  • Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
  • Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
  • Temperature Limits: 32 to 140°F (0 to 60°C).
  • Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
  • Repeatability: ±5% of setpoint.
  • Switch Type: SPDT.
  • Electrical Rating: 60 VAC/60 VDC @ 1 A.
  • Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
  • Process Connections: 3/4″ male NPT.
  • Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
  • Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
  • Setpoint Drift: 0.5% of setpoint.
  • Response Time: 1-10 seconds.
  • Viscosity Range: 1 to 200 centipoise.
  • Supply Voltage: 12 to 36 VDC.
  • Consumption: 50 mA (nominal).
  • Indication: LED for flow status.
  • Weight: 3 oz (94 g).
  • Agency Approvals: CE.
 

Dwyer TDS222 Thermal Dispersion Flow Switch

 
 
BrandDWYEr
Model Name/NumberTDS222
Connection Type3/4″ male NPT.
Setpoint Drift0.5% of setpoint
Response Time1-10 seconds
Viscosity Range1 to 200 centipoise
Supply Voltage12 to 36 VDC

Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.

Models & Ordering:
ModelDescription
TDS112Thermal dispersion flow switch, PP/PPS wetted parts, 3.0″ (7.6 cm) length.
TDS122Thermal dispersion flow switch, PP/PPS wetted parts, 4.5″ (11.4 cm) length.
TDS212Thermal dispersion flow switch, PVDF wetted parts, 3.0″ (7.6 cm) length.
TDS222Thermal dispersion flow switch, PVDF wetted parts, 4.5″ (11.4 cm) length.

Specifications:
  • Service: Liquids.
  • Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
  • Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
  • Temperature Limits: 32 to 140°F (0 to 60°C).
  • Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
  • Repeatability: ±5% of setpoint.
  • Switch Type: SPDT.
  • Electrical Rating: 60 VAC/60 VDC @ 1 A.
  • Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
  • Process Connections: 3/4″ male NPT.
  • Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
  • Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
  • Setpoint Drift: 0.5% of setpoint.
  • Response Time: 1-10 seconds.
  • Viscosity Range: 1 to 200 centipoise.
  • Supply Voltage: 12 to 36 VDC.
  • Consumption: 50 mA (nominal).
  • Indication: LED for flow status.
  • Weight: 3 oz (94 g).
  • Agency Approvals: CE.
 

Huba Control Transmitter Wholesalers Delhi India

Huba Control Transmitter 692.916007141

 
 
Minimum Order Quantity12 Number
Model Name/Number692.916007141
BrandHuba Control
Voltage11-33 VDC
Operating Range0-2.5bar
Protection TypeHuba Control Transmitter 692.916007141
Rated Supply Voltage11-33 VDC
Supply Voltage Limits11-33 VDC
Output Type4-20mA
Part TypeHuba Control Transmitter 692.916007141
Country of OriginMade in India

Huba Control Transmitter 692.916007141

Huba Control Relative and Differential Pressure Transmitter
  • Range – 0-2.5 Bar
  • Type -692 0-2.5 Bar
  • Out – 4-20mA In:11-33V DC
 

Huba Control Transmitter

 
 
Minimum Order Quantity12 Number
Usage/ApplicationLiquids And Gases
Model Name/Number692
BrandHuba Control
Voltage11-33 VDC
Accuracy< 0.5% fs
Operating Range0 … 0.1 – 25 bar
Protection TypeHuba Control Transmitter
Rated Supply Voltage11-33 VDC
Supply Voltage Limits11-33 VDC
Output Type0 … 5 V, 0 … 10 V, 4 … 20 mA
Part TypeHuba Control Transmitter
Country of OriginMade in India

Huba Control Transmitter

  • Differential Pressure Transmitter 692
  • 0 … 0.1 – 25 bar

The Pressure Transmitter Of Type 692 with proven, unique ceramic technology, features adjusted and amplified sensor signals which are available as standardised voltage or current outputs. Various application-specific pressure and electrical connections and housing materials suitable for different media can be provided.

  • Medium – Liquids and Gases
  • Pressure Range – 0 … 0.1 – 25 bar
  • Output – 0 … 5 V, 0 … 10 V, 4 … 20 mA
  • Accuracy –< 0.5% fs
  • Electrical Connection – Cable 1.5 m, Connector DIN EN 175301-803-A, connector DIN EN 60130-9
  • Pressure Connection – Hose Connection or Screw Fitting, Outside Thread, Adapter Inside- And Outside Thread
  • Mounting Bracket For Screw Mounting
 

Swiss Huba 625 Differential Switch 625.6532

 
 
Minimum Order Quantity12 Number
BrandHuba Control
Media TypeGas
Range Setting100-900 mBAR G1/4
Electrical ConnectionThreaded Terminal, 6.3 MM Flat Connector (AMP Connector)
Contact Materialplastic, brass and aluminium alloy, and NBR, FPM, EPDM and silicon diaphragm
Model Name/Number625.6532
Power/Voltage250 V AC
Weight200 gm
Minimum Order Quantity12
Country of OriginMade in India
Pressure ConnectionInside thread M5, hose connector +- 6 mm, outside thread

Swiss Huba 625 Differential  Switch 625.6532

  • Swiss Huba 625 Pressure Switch 625.6532 Fulba Control Pressure Controller-100-900mbar

HUBA 625 Membrane Mechanical Pressure Switch It has 13 Pressure Ranges and is Suitable For Liquids And Gases. The Main Materials Can Be Plastic, Brass And Aluminium Alloy, and NBR, FPM, EPDM and Silicon Diaphragm Can be Selected. High Accuracy And Long-Term Stability Can Be Obtained By Fine Tuning Measurement Steps. Reinforcement Design is Especially Suitable For General Industrial Equipment Structure, Processing Technology And Food Automation.

Technical Parameter

  • Relative Pressure-– 900-6000 mbar
  • Medium-Liquids And Gases
  • Maximum Overload Pressure-10 bar
  • Minimum Activation Pressure-2 mbar
  • Protection Level-IP54
  • Electrical Connectors-Threaded Terminal, 6.3 MM Flat Connector (AMP Connector)
  • Pressure Connector-Internal Thread M5, 6 MM Hose Connector;External Threads M12*1, G1/4, G1/8
  • Overpressure Medium Stop System (Explosion-Proof Hydrant)
  • Mounting Bracket

Main Application Areas

  • Vacuum Equipment
  • _Air Compressor
  • Food Machinery
  • Gas And Liquid Equipment

Often Sell Models

  • Huba 625.6132-Pressure Switch – 4 ~ – 30 mbar G1/4″
  • Huba 625.6232-Pressure Switch-15-80 mbar, G1/4
  • Huba 625.6532-Pressure Switch-100-900 mBAR G1/4
  • Huba 625.9032-Pressure Switch 2-8 mbar
  • Huba 625.9132-Pressure Switch 6-75 mbar G1/4″
  • Huba 625.9232-Pressure Switch 12.5-80 mBAR G 1/4
  • Huba 625.9432-Pressure Switch 25-220 mbar G1/4
  • Huba 625.9632-Pressure Switch 120-2200 mBAR G1/4
  • Huba 625.9732-Pressure Switch 1000-6000 MBAR 
 

Swiss Huba 625 Pressure Switch 625.6532

 
 
Minimum Order Quantity12 Number
Usage/ApplicationVacuum Equipment,_Air Compressor,Food Machinery,Gas And Liquid Equipment
BrandHuba Control
Media TypeGas
Range Setting100-900 mBAR G1/4
Electrical ConnectionThreaded Terminal, 6.3 MM Flat Connector (AMP Connector)
Contact Materialplastic, brass and aluminium alloy, and NBR, FPM, EPDM and silicon diaphragm
Model Name/Number625.6532
Power/Voltage250 V AC
Weight200 gm
Minimum Order Quantity12
Pressure ConnectionInside thread M5, hose connector +- 6 mm, outside thread

Swiss Huba 625 Pressure Switch 625.6532

  • Swiss Huba 625 Pressure Switch 625.6532 Fulba Control Pressure Controller-100-900mbar

HUBA 625 Membrane Mechanical Pressure Switch It has 13 Pressure Ranges and is Suitable For Liquids And Gases. The Main Materials Can Be Plastic, Brass And Aluminium Alloy, and NBR, FPM, EPDM and Silicon Diaphragm Can be Selected. High Accuracy And Long-Term Stability Can Be Obtained By Fine Tuning Measurement Steps. Reinforcement Design is Especially Suitable For General Industrial Equipment Structure, Processing Technology And Food Automation.

Technical Parameter

  • Relative Pressure-– 900-6000 mbar
  • Medium-Liquids And Gases
  • Maximum Overload Pressure-10 bar
  • Minimum Activation Pressure-2 mbar
  • Protection Level-IP54
  • Electrical Connectors-Threaded Terminal, 6.3 MM Flat Connector (AMP Connector)
  • Pressure Connector-Internal Thread M5, 6 MM Hose Connector;External Threads M12*1, G1/4, G1/8
  • Overpressure Medium Stop System (Explosion-Proof Hydrant)
  • Mounting Bracket

Main Application Areas

  • Vacuum Equipment
  • _Air Compressor
  • Food Machinery
  • Gas And Liquid Equipment

Often Sell Models

  • Huba 625.6132-Pressure Switch – 4 ~ – 30 mbar G1/4″
  • Huba 625.6232-Pressure Switch-15-80 mbar, G1/4
  • Huba 625.6532-Pressure Switch-100-900 mBAR G1/4
  • Huba 625.9032-Pressure Switch 2-8 mbar
  • Huba 625.9132-Pressure Switch 6-75 mbar G1/4″
  • Huba 625.9232-Pressure Switch 12.5-80 mBAR G 1/4
  • Huba 625.9432-Pressure Switch 25-220 mbar G1/4
  • Huba 625.9632-Pressure Switch 120-2200 mBAR G1/4
  • Huba 625.9732-Pressure Switch 1000-6000 MBAR 
 

Differential Pressure Transmitter DPT1-R8 SERIES

DPT1-R8 Sensocon USA Range Differential Pressure Transmitter

 
 
Minimum Order Quantity1 Number
Model Name/NumberDPT1-R8
BrandSensocon USA
Response Time0.8 – 4.0,jumper selectable
Maximum Pressure100 in w.c
Power Supply24 VDC or VAC,+/- 10%
Enclosure RatingIP 54/ NEMA 3
Display3 1/2 Digit LCD Backlit LCD

Series DPT DPT1-R8 Range Differential Pressure Transmitter Series DPT Selectable Range Differential Pressure Transmitter The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.

Technical Details:

DPT1-R8Range 1Range 2Range 3Range 4Range 5Range 6Range 7Range 8
inWC-0.1 – 0.1-0.25 – 0.25-0.5 – .05-1.0 – 01.00 – 0.10 – 0.250 – 0.50 – 1.0
Pa-25 – 25-62 – 62-125 – 125-250 – 2500 – 250 – 620 – 1250 – 250
mbar-0.25 – 0.25-0.62 – 0.62-1.25 – 1.25-2.5 – 2.50 – 0.250 – 0.620 – 1.250 – 2.5
mmWC-2.5 – 2.5-6.4 – 6.4-12.7 – 12.7-25.4 – 25.40 – 2.50 – 6.40 – 12.70-25.4

 

DPT1-R8 Sensocon USA Differential Pressure Transmitter Range -0.1-0.1 Inches wc

 
 
Minimum Order Quantity1 Number
Model NumberDPT1-R8
BrandSensocon USA
Frequency Range-0.1-0.1 Inches WC
Usage/ApplicationHVAC Industry
Response Time0.8 – 4.0,Jumper Selectable
Electrical ConnectionsScrew Terminal Block
Display3 1/2 Digit LCD Backlit LCD
Enclosure RatingIP 54/ NEMA 3
Power Supply24 VDC or VAC,+/- 10%
Media CompatibilityDry Air Or Non-aggressive Gases
Maximum Pressure100 in w.c.

DPT1-R8 Sensocon USA Differential Pressure Transmitter  Range -0.1-0.1 Inches wc

Applications:

  • DPT-R8 series devices are commonly used in HVAC/R systems for – Fan, blower and filter monitoring – Pressure and flow monitoring – Valve and damper control – Pressure monitoring in clean room

Warning:

  • Read These Instructions Carefully Before Attempting To Install, Operate Or Service This Device..
  • Failure to observe safety information and comply with instructions could result in Personal Injury, Death And/ Or Property Damage
  • To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.
  • To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.
  • Retain these instructions for future reference.
  • This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device.
 

DPT1-R8 Sensocon USA Differential Pressure Transmitter Range -0.25-0.25 Inches wc

 
 
Minimum Order Quantity1 Number
Model NumberDPT1-R8
BrandSensocon USA
Measuring Range-0.25-0.25 Inches WC
Usage/ApplicationPressure and Flow Monitoring – Valve and Damper Control – Pressure Monitoring in Clean Rooms
Response Time0.8 – 4.0,jumper selectable
Maximum Pressure100 in w.c.
Media CompatibilityDry Air Or Non-aggressive Gases
Power Supply24 VDC or VAC,+/- 10%
Enclosure RatingIP 54/ NEMA 3
Display3 1/2 Digit LCD Backlit LCD
Electrical ConnectionsScrew Terminal Block


DPT1-R8 Sensocon USA Differential Pressure Transmitter  Range -0.25-0.25 Inches wc

DPT-R8 series devices are commonly used in HVAC/R systems for:

 

  • Fan, blower and filter monitoring
  • Pressure and flow monitoring
  • Valve and damper control
  • Pressure monitoring in clean rooms

 

 

Warning:

  • Read These Instructions Carefully Before Attempting To Install, Operate Or Service This Device.
  • Failure to observe safety information and comply with instructions could result in Personal Injury, Death And/ Or Property Damage.
  • To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.
  • To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.
  • Retain these instructions for future reference.
  • This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device.

DPT1-R8 Sensocon USA Differential Pressure Transmitter Range -0.5-.05 Inches wc

 
 
Minimum Order Quantity1 Number
Model NumberDPT1-R8
BrandSensocon USA
Measuring Range-0.5-.05 Inches WC
Usage/ApplicationPressure and Flow Monitoring – Valve and Damper Control – Pressure Monitoring in Clean Rooms
Response Time0.8 – 4.0,Jumper Selectable
Maximum Pressure100 in w.c.
Media CompatibilityDry Air Or Non-aggressive Gases
Power Supply24 VDC or VAC,+/- 10%
Enclosure RatingIP 54/ NEMA 3
Display3 1/2 Digit LCD Backlit LCD
Electrical ConnectionsScrew Terminal Block

DPT1-R8 Sensocon USA Differential Pressure Transmitter  Range -0.5-.05 Inches wc

Applications:

  • DPT-R8 series devices are commonly used in HVAC/R systems for – Fan, blower and filter monitoring – Pressure and flow monitoring – Valve and damper control – Pressure monitoring in clean rooms

Warning:

  • Read These Instructions Carefully Before Attempting To Install, Operate Or Service This Device.
  • Failure to observe safety information and comply with instructions could result in Personal Injury, Death And/ Or Property Damage.
  • To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.
  • To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.
  • Retain these instructions for future reference.
  • This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device.