Converts all type of Thermocouple, RTD, Ohms, mV into 4 to 20mA analogue output
Model Name/Number
GALAXY
Brand
GALAXY
Rated Supply Voltage
10 to 32 VDC
Supply Voltage Limits
10 to 32 VDC
Output Type
2 Wire, 4 to 20mA
Part Type
Universal Type Temperature Transmitter
Country of Origin
Made in India
Input Value
All type of Thermocouple, RTDs, Ohms, mV
Programming & Calibration
User friendly software and a USB Calibrator
Mounting
Head Mount
Universal Type Temperature Transmitter
PC Programmable Head Mount Temperture Transmitter Which Converts All Tc, RTD, Ohms Mv Into a Scalable Analogue Signal Of 4 to 20ma. Performance
2-Wire Technology, 4 to 20ma Analogue Output.
High Accuracy In Total Ambient Temperature Range.
Internal Cold Junction Compensation.
Wide Voltage Supply Range.
Customer Specific Measurement Range Setting Or Expanded Setup.
Simple And User Friendly Software.
USB Communication.
INPUT
Type : TC, RTD, Ohms, mV
Measurement Ranges : -200 to 850°c
Connection Type : 3-Wire Connection
OUTPUT
Output Signal : 2 Wire, 4 to 20ma Scalable Analogue Signal Output
Current Alarm Output : 3. 6ma or 22ma When Sensor Damage Or Break.
TECHNICAL SPECIFICATIONS
Damp : 0-32s
Current Limit : ≤ 22ma
Saturation Current : Low 3. 8ma ; High 20. 6ma
Response Time : ≤ 0. 8s
Data Refresh Rate : 4 Times/Sec
Accuracy : ± 0. 1%
Stability :0. 01 ??c
Power Supply : 10 to 32 VDC
Temperature Transmitters
Minimum Order Quantity
12 Number
Usage/Application
Converts RTD & Thermocouple Input into linear scalable 4 to 20mA.
Model Name/Number
TR 213
Brand
GALAXY
Voltage
24 VDC
Rated Supply Voltage
24 VDC
Output Type
2 Wire,4 to 20mA
Country of Origin
Made in India
Input Value
Universal All type of RTD & Thermocouple Input
Temperature Transmitters
TT 210 is a Head Mount Non isolated universal temperature transmitter for resistance thermometers (RTD), thermocouples (TC), resistance & voltage (mV) which converts all these data signals into scalable 4 to 20mA analogue output signal.
This is a user programmable temperature transmitter which can be programmed for input signal from ANDROID SMART PHONE or LAPTOP via data cable & user friendly operating software.
Performance Features:
2 wire technology 4 to 20 mA analogue output.
High accuracy in total ambient temperature range.
An internal temperature sensor for active temperature compensation.
Wide voltage supply range.
Customer specific measurement range setting.
Simple & user friendly software
USB Communication
Technical Data
Input RTD, TC, OHM, mV
Output 4 to 20 mA
Supply voltage 7.5 to 45 VDC
Cold junction Internal
Influence of ambient Negligible
Load influence Negligible
Power supply influence Negligible
Resolution 0.3 uA
Installation Sensor head from B
Operation PC – programmable
Weight Approx. 35 GMS
Dimensions 44 MM × 22. 5 MM (Φ × H)
RTD PT 100 Temperature Transmitter
Minimum Order Quantity
12 Piece
Usage/Application
Use for converting RTD Signal into scalable analog Input signal 4 to 20mA
Model Name/Number
RTD PT 100
Brand
GALAXY
Voltage
10 to 32 VDC
Accuracy
+- 0.1%
Protection Type
RTD PT 100 Temperature Transmitter
Output Type
4 to 20mA
Part Type
RTD PT 100 Temperature Transmitter
Country of Origin
Made in India
Programming
Can be programmed with user freindly software & USB
RTD PT 100 Temperature Transmitter
PC Programmable Head Mount Temperture Transmitter Which Converts All Tc, RTD, Ohms Mv Into a Scalable Analogue Signal Of 4 to 20ma. Performance
2-Wire Technology, 4 to 20ma Analogue Output.
High Accuracy In Total Ambient Temperature Range.
Internal Cold Junction Compensation.
Wide Voltage Supply Range.
Customer Specific Measurement Range Setting Or Expanded Setup.
Simple And User Friendly Software.
USB Communication.
INPUT
Type : TC, RTD, Ohms, mV ( RTD PT 100 )
Measurement Ranges : -200 to 850°c
Connection Type : 3-Wire Connection
OUTPUT
Output Signal : 2 Wire, 4 to 20ma Scalable Analogue Signal Output
Current Alarm Output : 3. 6ma or 22ma When Sensor Damage Or Break.
2000-60PA-ASF Dwyer Instruments Select the Magnehelic gage for high accuracy–guaranteed within 2% of full scale–and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer’s simple, frictionless Magnehelic gage movement, it quickly indicates low air or non-corrosive gas pressures–either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It’s inexpensive, too. The Magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment
Product Highlights
Bezel provides flange for flush mounting in panel.
Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.
Precision litho-printed scale is accurate and easy to read.
Red tipped pointer of heat treated
aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.
Pointer stops of molded rubber prevent pointer over-travel without damage.
“Wishbone” assembly provides mounting for helix, helix bearings and pointer shaft.
Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.
Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.
Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.
Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.
Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test.
Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.
Overpressure Protection: Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the gage interior when over pressure reaches approximately 25 PSIg (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023″ clearance when gage is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180″ of water pressure, medium or high pressure models, or on gages which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gage to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component. O-ring seal for cover assures pressure integrity of case. Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.
Range 0-60 Pa
Adjustable set flag
Series TDFS Thermal Dispersion Flow Switch
Minimum Order Quantity
1 No
Brand
Dwyer USA
Agency Approvals
CE
Housing Materials
316 SS, 416 SS, Polycarbonate, Neoprene, And Acrylated Urethane
Enclosure Rating
NEMA 4X (IP65)
Process Connection
1/2″ NPT male
Electrical Connection
4 conductor 22 AWG, 6′ (1.83 m) long with cable gland
Current Consumption
Average:93 mA, Peak: 300 mA
Power Requirement
9 to 24 VDC
Response Time
Approximately 8 s
Pressure Limits
300 psig (20.67 bar)
Wetted Materials
316 SS, Polysulfone, and FKM
Setpoint Range
0.5 to 10 ft/s (0.15 to 3.0 m/s)
Repeatability
0.07 ft/s +3% of setpoint
Switching Current
400 mA, derate 5 mA/ deg C above 23 deg C
Series TDFS Thermal Dispersion Flow Switch
OLD Modal TDFS-1-P-06
NEW Modal TDFS-2-P-06
The Series TDFS2 Thermal Dispersion Flow Switch is a thermal flow switch that indicates whether the flow rate is above or below a user set flow rate. The unit incorporates two LED status indicators providing visual switch indication. The set flow rate (setpoint) is field adjustable and the unit has both NO and NC NPN outputs. See Figure 1 on catalog page for output and LED actions on change of flow
Product Applications:
Boiler Flow Proving
Hot Water Heaters
Chillers
Liquid Transfer Systems
Model – TDFS2-1-P-06 Thermal Dispersion Flow Switch, 316SS, 1/2″ NPT Process Connection, 6′ of Cable With Cable Gland.
4 conductor 22 AWG,6′ (1.83 m) long with cable gland
Current Consumption
Average:93 mA,Peak: 300 mA
Switching Current
400 mA,derate 5 mA/ deg C above 23 deg C
Power Requirement
9 to 24 VDC
Response Time
Approximately 8 s
Pressure Limits
300 psig (20.67 bar)
Typical Deadband
0.1 ft/s +15% of setpoint
Repeatability
0.07 ft/s +3% of setpoint
Setpoint Range
0.5 to 10 ft/s (0.15 to 3.0 m/s)
Wetted Materials
316 SS,Polysulfone,and FKM
TDFS-1-P-06 Thermal Dispersion Flow Switch
OLD Modal TDFS-1-P-06
NEW Modal TDFS-2-P-06
The Series TDFS2 Thermal Dispersion Flow Switch is a thermal flow switch that indicates whether the flow rate is above or below a user set flow rate. The unit incorporates two LED status indicators providing visual switch indication. The set flow rate (setpoint) is field adjustable and the unit has both NO and NC NPN outputs. See Figure 1 on catalog page for output and LED actions on change of flow
Product Applications:
Boiler Flow Proving
Hot Water Heaters
Chillers
Liquid Transfer Systems
Model – TDFS2-1-P-06
Thermal Dispersion Flow Switch, 316SS, 1/2″ NPT Process Connection, 6′ of Cable With Cable Gland.
My Vibration-Sine curve: 20 g, 25 Hz to 2 kHz; IEC 60068-2-6,Random: 7.5 grms, 5 Hz to 1 kHz; IEC 60068-2-64
My Shock-Shock: 200g/1ms; IEC 60068-2-27,Free???1m???IEC 60068-2-32
Protection-IP65
Bibliography-IEC 61000-4-5 level 1
My Voltage-500V/AC 1min
Static-IEC 61000-4-2 2level
Media Compatibility-All Media Compatible With 316L Stainless Steel
Hexagon-Sandblasting HEX27
Explosion-Proof Rating
Intrinsically Safe Explosion-Proof Exia???CT6
Weight-100 ~ 150g
Output And Supply Power
Code- B1 – Customized
Print – 4 to 20mA, –
Supply Power – 12 ???36VDC –
Galaxy Pressure Transmitter PCM313 Range 0 To 500 MBAR
Minimum Order Quantity
12 Piece
Usage/Application
Process Control,Aerospace,Automotive And Medical Equipment,Pipeline System
Model Name/Number
PCM313
Brand
Galaxy
Voltage
12-36VDC
Accuracy
0.5%FS
Product Weight
100-150g
Protection Type
Galaxy Pressure Transmitter PCM313 Range 0 To 500 MBAR
Rated Supply Voltage
12-36VDC
Supply Voltage Limits
12-36VDC
Output Type
4 to 20mA
Part Type
Galaxy Pressure Transmitter PCM313 Range 0 To 500 MBAR
Country of Origin
Made in India
Galaxy Pressure Transmitter PCM313 Range 0 To 500 MBAR
PCM313PRESSURE TRANSMITTER Product Overview
GALAXY economic pressure transmitter adopts diffused silicon pressure sensor as pressure sensing element.Through internal ASIC,the millivolt signal of sensor is transmitted into standard current signal.GALAXY can be directly connected with computer interface card,control instruments,intelligent meters or PLC etc.conveniently.Long-distance transmission can use current output.GALAXY features with small size,light weight,all stainless steelsealing structure and ability to work in corrosive environments.The product is easy to install and has extremely high vibration and shock resistance.GALAXY is widely used in processcontrol,aviation,aerospace,automobile,medical equipment,HVAC and otherfields Notes:
Do not misusedocumentation
The information presented in this product sheet is forreference only.Do not use this document as a product installationguide
Complete installation,operation,and maintenance informationis provided in the instructions of theproduct.
Misuse of the product may cause danger or personalinjury
Voltage Resistance–Current Output-500V/AC 1min Voltage Output-250V/AC 1min
Static Electricity-IEC 61000-4-2 4 level
Hexagon-HEX27
Ex-Proof Grade-Intrinsically safe explosion-proof ExiaIICT6 (only for 4-20mA)
Net Weight-150-180g
Galaxy Pressure Transmitter PCM313 Range 0 To 100 Mbar
Minimum Order Quantity
12 Piece
Usage/Application
Process Control,Aerospace,Automotive And Medical Equipment,Pipeline System
Model Name/Number
PCM313
Brand
Galaxy
Voltage
12-36VDC
Accuracy
0.5%FS
Product Weight
100-150g
Protection Type
Galaxy Pressure Transmitter PCM313 Range 0 To 100 Mbar
Rated Supply Voltage
12-36VDC
Supply Voltage Limits
12-36VDC
Output Type
4 to 20mA
Part Type
Galaxy Pressure Transmitter PCM313 Range 0 To 100 Mbar
Country of Origin
Made in India
Galaxy Pressure Transmitter PCM313 Range 0 To 100 Mbar
PCM313PRESSURE TRANSMITTER Product Overview
GALAXY economic pressure transmitter adopts diffused silicon pressure sensor as pressure sensing element.Through internal ASIC,the millivolt signal of sensor is transmitted into standard current signal.GALAXY can be directly connected with computer interface card,control instruments,intelligent meters or PLC etc.conveniently.Long-distance transmission can use current output.GALAXY features with small size,light weight,all stainless steelsealing structure and ability to work in corrosive environments.The product is easy to install and has extremely high vibration and shock resistance.GALAXY is widely used in processcontrol,aviation,aerospace,automobile,medical equipment,HVAC and otherfields Notes:
Do not misusedocumentation
The information presented in this product sheet is forreference only.Do not use this document as a product installationguide
Complete installation,operation,and maintenance informationis provided in the instructions of theproduct.
Misuse of the product may cause danger or personalinjury
Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe s
Measuring Range
Range 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
Brand
DWYER
Usage/Application
Liquids.
Model Name/Number
Series TDS
Material/Body
Polypropylene/PPS or Polyvinylidene Fluoride.
Process Temperature
32 to 140 DegreeF (0 to 60 DegreeC).
Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.
Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
Temperature Limits: 32 to 140°F (0 to 60°C).
Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
Repeatability: ±5% of setpoint.
Switch Type: SPDT.
Electrical Rating: 60 VAC/60 VDC @ 1 A.
Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
Process Connections: 3/4″ male NPT.
Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
Setpoint Drift: 0.5% of setpoint.
Response Time: 1-10 seconds.
Viscosity Range: 1 to 200 centipoise.
Supply Voltage: 12 to 36 VDC.
Consumption: 50 mA (nominal).
Indication: LED for flow status.
Weight: 3 oz (94 g).
Agency Approvals: CE.
Dwyer TDS112 Thermal Dispersion Flow Switch
Brand
Dwyer
Model Name/Number
TDS 112
Connection Type
3/4″ male NPT.
Weight
3 oz (94 g)
Setpoint Drift
0.5% of setpoint
Response Time
1-10 sec
Viscosity Range
1 to 200 centipoise
Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.
Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
Temperature Limits: 32 to 140°F (0 to 60°C).
Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
Repeatability: ±5% of setpoint.
Switch Type: SPDT.
Electrical Rating: 60 VAC/60 VDC @ 1 A.
Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
Process Connections: 3/4″ male NPT.
Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
Setpoint Drift: 0.5% of setpoint.
Response Time: 1-10 seconds.
Viscosity Range: 1 to 200 centipoise.
Supply Voltage: 12 to 36 VDC.
Consumption: 50 mA (nominal).
Indication: LED for flow status.
Weight: 3 oz (94 g).
Agency Approvals: CE.
Dwyer TDS122 Thermal Dispersion Flow Switch
Brand
DWYER
Weight
3 oz (94 g)
Consumption
50 mA (nominal)
Supply Voltage
12 to 36 VDC
Viscosity Range
1 to 200 centipoise
Response Time
1-10 sec
Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.
Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
Temperature Limits: 32 to 140°F (0 to 60°C).
Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
Repeatability: ±5% of setpoint.
Switch Type: SPDT.
Electrical Rating: 60 VAC/60 VDC @ 1 A.
Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
Process Connections: 3/4″ male NPT.
Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
Setpoint Drift: 0.5% of setpoint.
Response Time: 1-10 seconds.
Viscosity Range: 1 to 200 centipoise.
Supply Voltage: 12 to 36 VDC.
Consumption: 50 mA (nominal).
Indication: LED for flow status.
Weight: 3 oz (94 g).
Agency Approvals: CE.
Dwyer TDS212 Thermal Dispersion Flow Switch
Brand
DWYER
Model Name/Number
TDS212
Connection Type
3/4″ male NPT.
Setpoint Drift
0.5% of setpoint
Response Time
1-10 sec
Viscosity Range
1 to 200 centipoise
Supply Voltage
12 to 36 VDC
Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.
Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
Temperature Limits: 32 to 140°F (0 to 60°C).
Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
Repeatability: ±5% of setpoint.
Switch Type: SPDT.
Electrical Rating: 60 VAC/60 VDC @ 1 A.
Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
Process Connections: 3/4″ male NPT.
Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
Setpoint Drift: 0.5% of setpoint.
Response Time: 1-10 seconds.
Viscosity Range: 1 to 200 centipoise.
Supply Voltage: 12 to 36 VDC.
Consumption: 50 mA (nominal).
Indication: LED for flow status.
Weight: 3 oz (94 g).
Agency Approvals: CE.
Dwyer TDS222 Thermal Dispersion Flow Switch
Brand
DWYEr
Model Name/Number
TDS222
Connection Type
3/4″ male NPT.
Setpoint Drift
0.5% of setpoint
Response Time
1-10 seconds
Viscosity Range
1 to 200 centipoise
Supply Voltage
12 to 36 VDC
Adjustable Switch Point, LED Indication The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.
Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
Temperature Limits: 32 to 140°F (0 to 60°C).
Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated @ 1.667 psi (.113 bar) per °C above 25°C.
Repeatability: ±5% of setpoint.
Switch Type: SPDT.
Electrical Rating: 60 VAC/60 VDC @ 1 A.
Electrical Connections: 22 AWG 3-wire, 10 ft (3 m) length.
Process Connections: 3/4″ male NPT.
Mounting Orientation: Any orientation, for pipe sizes 3/4″ to 1-1/2″ use 3.0″ (7.6 cm) length switch; for 2″ to 16″ pipe sizes use 4.5″ (11.4 cm) length switch.
Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
Huba Control Relative and Differential Pressure Transmitter
Range – 0-2.5 Bar
Type -692 0-2.5 Bar
Out – 4-20mA In:11-33V DC
Huba Control Transmitter
Minimum Order Quantity
12 Number
Usage/Application
Liquids And Gases
Model Name/Number
692
Brand
Huba Control
Voltage
11-33 VDC
Accuracy
< 0.5% fs
Operating Range
0 … 0.1 – 25 bar
Protection Type
Huba Control Transmitter
Rated Supply Voltage
11-33 VDC
Supply Voltage Limits
11-33 VDC
Output Type
0 … 5 V, 0 … 10 V, 4 … 20 mA
Part Type
Huba Control Transmitter
Country of Origin
Made in India
Huba Control Transmitter
Differential Pressure Transmitter 692
0 … 0.1 – 25 bar
The Pressure Transmitter Of Type 692 with proven, unique ceramic technology, features adjusted and amplified sensor signals which are available as standardised voltage or current outputs. Various application-specific pressure and electrical connections and housing materials suitable for different media can be provided.
Medium – Liquids and Gases
Pressure Range – 0 … 0.1 – 25 bar
Output – 0 … 5 V, 0 … 10 V, 4 … 20 mA
Accuracy –< 0.5% fs
Electrical Connection – Cable 1.5 m, Connector DIN EN 175301-803-A, connector DIN EN 60130-9
Pressure Connection – Hose Connection or Screw Fitting, Outside Thread, Adapter Inside- And Outside Thread
Mounting Bracket For Screw Mounting
Swiss Huba 625 Differential Switch 625.6532
Minimum Order Quantity
12 Number
Brand
Huba Control
Media Type
Gas
Range Setting
100-900 mBAR G1/4
Electrical Connection
Threaded Terminal, 6.3 MM Flat Connector (AMP Connector)
Contact Material
plastic, brass and aluminium alloy, and NBR, FPM, EPDM and silicon diaphragm
Model Name/Number
625.6532
Power/Voltage
250 V AC
Weight
200 gm
Minimum Order Quantity
12
Country of Origin
Made in India
Pressure Connection
Inside thread M5, hose connector +- 6 mm, outside thread
Swiss Huba 625 Differential Switch 625.6532
Swiss Huba 625 Pressure Switch 625.6532 Fulba Control Pressure Controller-100-900mbar
HUBA 625 Membrane Mechanical Pressure Switch It has 13 Pressure Ranges and is Suitable For Liquids And Gases. The Main Materials Can Be Plastic, Brass And Aluminium Alloy, and NBR, FPM, EPDM and Silicon Diaphragm Can be Selected. High Accuracy And Long-Term Stability Can Be Obtained By Fine Tuning Measurement Steps. Reinforcement Design is Especially Suitable For General Industrial Equipment Structure, Processing Technology And Food Automation. Technical Parameter
Relative Pressure-– 900-6000 mbar
Medium-Liquids And Gases
Maximum Overload Pressure-10 bar
Minimum Activation Pressure-2 mbar
Protection Level-IP54
Electrical Connectors-Threaded Terminal, 6.3 MM Flat Connector (AMP Connector)
Vacuum Equipment,_Air Compressor,Food Machinery,Gas And Liquid Equipment
Brand
Huba Control
Media Type
Gas
Range Setting
100-900 mBAR G1/4
Electrical Connection
Threaded Terminal, 6.3 MM Flat Connector (AMP Connector)
Contact Material
plastic, brass and aluminium alloy, and NBR, FPM, EPDM and silicon diaphragm
Model Name/Number
625.6532
Power/Voltage
250 V AC
Weight
200 gm
Minimum Order Quantity
12
Pressure Connection
Inside thread M5, hose connector +- 6 mm, outside thread
Swiss Huba 625 Pressure Switch 625.6532
Swiss Huba 625 Pressure Switch 625.6532 Fulba Control Pressure Controller-100-900mbar
HUBA 625 Membrane Mechanical Pressure Switch It has 13 Pressure Ranges and is Suitable For Liquids And Gases. The Main Materials Can Be Plastic, Brass And Aluminium Alloy, and NBR, FPM, EPDM and Silicon Diaphragm Can be Selected. High Accuracy And Long-Term Stability Can Be Obtained By Fine Tuning Measurement Steps. Reinforcement Design is Especially Suitable For General Industrial Equipment Structure, Processing Technology And Food Automation. Technical Parameter
Relative Pressure-– 900-6000 mbar
Medium-Liquids And Gases
Maximum Overload Pressure-10 bar
Minimum Activation Pressure-2 mbar
Protection Level-IP54
Electrical Connectors-Threaded Terminal, 6.3 MM Flat Connector (AMP Connector)
DPT1-R8 Sensocon USA Range Differential Pressure Transmitter
Minimum Order Quantity
1 Number
Model Name/Number
DPT1-R8
Brand
Sensocon USA
Response Time
0.8 – 4.0,jumper selectable
Maximum Pressure
100 in w.c
Power Supply
24 VDC or VAC,+/- 10%
Enclosure Rating
IP 54/ NEMA 3
Display
3 1/2 Digit LCD Backlit LCD
Series DPT DPT1-R8 Range Differential Pressure Transmitter Series DPT Selectable Range Differential Pressure Transmitter The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.
Technical Details:
DPT1-R8
Range 1
Range 2
Range 3
Range 4
Range 5
Range 6
Range 7
Range 8
inWC
-0.1 – 0.1
-0.25 – 0.25
-0.5 – .05
-1.0 – 01.0
0 – 0.1
0 – 0.25
0 – 0.5
0 – 1.0
Pa
-25 – 25
-62 – 62
-125 – 125
-250 – 250
0 – 25
0 – 62
0 – 125
0 – 250
mbar
-0.25 – 0.25
-0.62 – 0.62
-1.25 – 1.25
-2.5 – 2.5
0 – 0.25
0 – 0.62
0 – 1.25
0 – 2.5
mmWC
-2.5 – 2.5
-6.4 – 6.4
-12.7 – 12.7
-25.4 – 25.4
0 – 2.5
0 – 6.4
0 – 12.7
0-25.4
DPT1-R8 Sensocon USA Differential Pressure Transmitter Range -0.1-0.1 Inches wc
Minimum Order Quantity
1 Number
Model Number
DPT1-R8
Brand
Sensocon USA
Frequency Range
-0.1-0.1 Inches WC
Usage/Application
HVAC Industry
Response Time
0.8 – 4.0,Jumper Selectable
Electrical Connections
Screw Terminal Block
Display
3 1/2 Digit LCD Backlit LCD
Enclosure Rating
IP 54/ NEMA 3
Power Supply
24 VDC or VAC,+/- 10%
Media Compatibility
Dry Air Or Non-aggressive Gases
Maximum Pressure
100 in w.c.
DPT1-R8 Sensocon USA Differential Pressure Transmitter Range -0.1-0.1 Inches wc
Applications:
DPT-R8 series devices are commonly used in HVAC/R systems for – Fan, blower and filter monitoring – Pressure and flow monitoring – Valve and damper control – Pressure monitoring in clean room
Warning:
Read These Instructions Carefully Before Attempting To Install, Operate Or Service This Device..
Failure to observe safety information and comply with instructions could result in Personal Injury, Death And/ Or Property Damage
To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.
To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.
Retain these instructions for future reference.
This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device.
DPT1-R8 Sensocon USA Differential Pressure Transmitter Range -0.25-0.25 Inches wc
Minimum Order Quantity
1 Number
Model Number
DPT1-R8
Brand
Sensocon USA
Measuring Range
-0.25-0.25 Inches WC
Usage/Application
Pressure and Flow Monitoring – Valve and Damper Control – Pressure Monitoring in Clean Rooms
Response Time
0.8 – 4.0,jumper selectable
Maximum Pressure
100 in w.c.
Media Compatibility
Dry Air Or Non-aggressive Gases
Power Supply
24 VDC or VAC,+/- 10%
Enclosure Rating
IP 54/ NEMA 3
Display
3 1/2 Digit LCD Backlit LCD
Electrical Connections
Screw Terminal Block
DPT1-R8 Sensocon USA Differential Pressure Transmitter Range -0.25-0.25 Inches wc
DPT-R8 series devices are commonly used in HVAC/R systems for:
Fan, blower and filter monitoring
Pressure and flow monitoring
Valve and damper control
Pressure monitoring in clean rooms
Warning:
Read These Instructions Carefully Before Attempting To Install, Operate Or Service This Device.
Failure to observe safety information and comply with instructions could result in Personal Injury, Death And/ Or Property Damage.
To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.
To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.
Retain these instructions for future reference.
This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device.
DPT1-R8 Sensocon USA Differential Pressure Transmitter Range -0.5-.05 Inches wc
Minimum Order Quantity
1 Number
Model Number
DPT1-R8
Brand
Sensocon USA
Measuring Range
-0.5-.05 Inches WC
Usage/Application
Pressure and Flow Monitoring – Valve and Damper Control – Pressure Monitoring in Clean Rooms
Response Time
0.8 – 4.0,Jumper Selectable
Maximum Pressure
100 in w.c.
Media Compatibility
Dry Air Or Non-aggressive Gases
Power Supply
24 VDC or VAC,+/- 10%
Enclosure Rating
IP 54/ NEMA 3
Display
3 1/2 Digit LCD Backlit LCD
Electrical Connections
Screw Terminal Block
DPT1-R8 Sensocon USA Differential Pressure Transmitter Range -0.5-.05 Inches wc
Applications:
DPT-R8 series devices are commonly used in HVAC/R systems for – Fan, blower and filter monitoring – Pressure and flow monitoring – Valve and damper control – Pressure monitoring in clean rooms
Warning:
Read These Instructions Carefully Before Attempting To Install, Operate Or Service This Device.
Failure to observe safety information and comply with instructions could result in Personal Injury, Death And/ Or Property Damage.
To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.
To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.
Retain these instructions for future reference.
This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device.
The Series DX is a Differential Pressure Switch that makes a contact output based on the differential between two pressure sources. Wetted Materials of Brass and Fluoroelastomer are suitable for use with most Gases and Water-based solutions. Standard is a Weatherproof, UL type 4X, an enclosure for dust-laden, outdoor, or wash-down installation environments. Series DX incorporates an externally adjustable set point, integral mounting flange and a removable electrical terminal block for quick and easy installation. The DX uses opposing diaphragms to sense the high and low pressure with a pivot mechanism that transfers the difference of the two pressures to the SPDT Switch.
Product Applications:
Indicating Filter Differential Pressure. For example initiating Water Filter backwash as the filter becomes clogged on increasing Differential Pressure.Proof of flow indicator monitoring differential pressure from a sensing device. For example sensing the pressure across an orifice plate to prove water flow.Proving flow through a pump by sensing the pressure across the pump to make sure the pump does not run dry.Proving flow through a chiller. Often called evaporator water pressure drop.Proving flow through a heat pump or AC unit. Often called a condenser water lock-out switch.
Dwyer DXW-11-153-1 Differential Pressure Switch
Model Name/Number
DXW-11-153-1
Brand
Dwyer
Voltage
125/250 VAC or 30 VDC
Usage/Application
Industrial Process Monitoring
Product Weight
1 lb 3 oz (0.54 kg
Pressure Transmitters Type
Wet Differential Pressure Transmitter
The Series DX is a Differential Pressure Switch that makes a contact output based on the Differential Between Two Pressure sources. Wetted materials of brass and flouroelastomer are suitable for use with most Gases and Water Based Solutions. The Switch can be used for low differential pressure indication with set point on a decrease of pressure as low as 1 psid (0.07 bar). Differential set point ranges are available from 2.5 to 75 psid (0.17 to 5.17 bar) on increasing Differential Pressure and 1.0 to 67 psid (0.07 to 4.62 bar) on decreasing Differential Pressure. Unit features a high static pressure rating of 200 psig (13.8 bar). Weatherproof, UL type 4X, enclosure for dust laden, outdoor, or wash-down installation environments. Externally Adjustable Set point, integral mounting flange and a removable electrical terminal block for Quick and Easy Installation.
Details: • Weather Proof Housing provides protection in the harsh,wet or dirty environments insuring switch’s long-service life • Removable Terminal Block Reduces Installation Time
Process Connection:1/4″ FNPT, Conduit Connection: 0.871″ Hole For 1/2″ Conduit Fitting; Electrical Connection: Removable Terminal Block
SENSOR TYPE:
Pressure Sensor
PRESSURE RANGE
0 – 100 psid
MAX TEMPERATURE
30 to 140°F
APPLICATIONS
For Indicating Filter Differential Pressure, Proof Of Flow Indicator Monitoring Differential Pressure From A Sensing Device, Proving Flow Through A Pump, Chiller and Heat Pump or AC Unit
Process Connection1/4″ FNPT, Conduit Connection 0.871″ Hole For 1/2″ Conduit Fitting; Electrical Connection Removable Terminal Block
Model Name/Number
DXW-11-153-2
Weight
1 lb 3 oz (0.54 kg
Mounting Type
Ports on horizontal plane, +-10 Degree.
The Series DX is a Differential Pressure Switch that makes a contact output based on the Differential Between two pressure sources. Wetted Materials of Brass and Flouroelastomer are suitable for use with most Gases and Water Based Solutions. The Switch can be used for low Differential Pressure Indication with set point on a decrease of pressure as low as 1 psid (0.07 bar). Differential set point ranges are available from 2.5 to 75 psid (0.17 to 5.17 bar) on increasing differential pressure and 1.0 to 67 psid (0.07 to 4.62 bar) on decreasing Differential Pressure. Unit features a high static pressure rating of 200 psig (13.8 bar). Weatherproof, UL type 4X, enclosure for dust laden, outdoor, or wash-down installation environments. Externally adjustable set point, integral mounting flange and a removable electrical terminal block for quick and easy installation.
Details: • Weatherproof Housing Provides protection in the harsh, wet or dirty environments insuring switch’s long-service life • Removable Terminal Block Reduces Installation Time
Process Connection:1/4″ FNPT, Conduit Connection: 0.871″ Hole For 1/2″ Conduit Fitting; Electrical Connection: Removable Terminal Block
SENSOR TYPE:
Pressure Sensor
PRESSURE RANGE
200 psig
RELATIVE HUMIDITY RANGE
80%
MAX TEMPERATURE
30 to 140°F
FREQUENCY
5 – 500 Hz
APPLICATIONS
For Indicating Filter Differential Pressure, Proof Of Flow Indicator Monitoring Differential Pressure From A Sensing Device, Proving Flow Through A Pump, Chiller and Heat Pump or AC Unit
The Series DX is a Differential Pressure Switch that Makes a contact output based on the differential between two pressure sources. Wetted materials of brass and flouroelastomer are suitable for use with most gases and water based solutions. The switch can be used for low differential pressure indication with set point on a decrease of pressure as low as 1 psid (0.07 bar). Differential set point ranges are available from 2.5 to 75 psid (0.17 to 5.17 bar) on increasing differential pressure and 1.0 to 67 psid (0.07 to 4.62 bar) on decreasing differential pressure. Unit features a high static pressure rating of 200 psig (13.8 bar). Weatherproof, UL type 4X, enclosure for dust laden, outdoor, or wash-down installation environments. Externally adjustable set point, integral mounting flange and a removable electrical terminal block for quick and easy installation.
Details: • Weatherproof housing provides protection in the harsh, wet or dirty environments insuring switch’s long-service life • Removable terminal block reduces installation time
Process Connection:1/4″ FNPT, Conduit Connection: 0.871″ Hole For 1/2″ Conduit Fitting; Electrical Connection: Removable Terminal Block
SENSOR TYPE:
Pressure Sensor
PRESSURE RANGE
200 psig
RELATIVE HUMIDITY RANGE
80%
MAX TEMPERATURE
30 to 140°F
FREQUENCY
5 – 500 Hz
APPLICATIONS
For Indicating Filter Differential Pressure, Proof Of Flow Indicator Monitoring Differential Pressure From A Sensing Device, Proving Flow Through A Pump, Chiller and Heat Pump or AC Unit
The Series DX is a Differential Pressure Switch that makes a contact output based on the differential between two pressure sources. Wetted materials of brass and flouroelastomer are suitable for use with most gases and water based solutions. The switch can be used for low differential pressure indication with set point on a decrease of pressure as low as 1 psid (0.07 bar). Differential set point ranges are available from 2.5 to 75 psid (0.17 to 5.17 bar) on increasing differential pressure and 1.0 to 67 psid (0.07 to 4.62 bar) on decreasing differential pressure. Unit features a high static pressure rating of 200 psig (13.8 bar). Weatherproof, UL type 4X, enclosure for dust laden, outdoor, or wash-down installation environments. Externally adjustable set point, integral mounting flange and a removable electrical terminal block for quick and easy installation.
Details: • Weatherproof Housing provides protection in the harsh, wet or dirty environments insuring Switch’s Long-Service Life • Removable Terminal Block Reduces Installation Time
Process Connection:1/4″ FNPT, Conduit Connection: 0.871″ Hole For 1/2″ Conduit Fitting; Electrical Connection: Removable Terminal Block
SENSOR TYPE:
Pressure Sensor
PRESSURE RANGE
200 psig
RELATIVE HUMIDITY RANGE
80%
MAX TEMPERATURE
30 to 140°F
FREQUENCY
5 – 500 Hz
APPLICATIONS
For Indicating Filter Differential Pressure, Proof Of Flow Indicator Monitoring Differential Pressure From A Sensing Device, Proving Flow Through A Pump, Chiller and Heat Pump or AC Unit
The Series DCT600 Timer Controller is a timing system for pulse-jet type dust collectors or pneumatic conveying systems in either continuous or on-demand cleaning applications. It provides either 4, 6, 10, 22 or 32 channels. The DCT600 was designed for ease of installation in your dust collector system. For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel. Time-on and time-off settings are selected using two potentiometers. High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode. The new enhanced board circuitry of the DCT600 synchronizes the on-time pulse to the power line to achieve a pulse stability of ±1 msec. For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line. Product Applications
Dust Collection
Pneumatic Conveying
Models & Ordering
Model Description
DCT604 Timer Controller, 4 Channels.
DCT606 Timer Controller, 6 Channels.
DCT610 Timer Controller, 10 Channels.
DCT622 Timer Controller, 22 Channels.
DCT632 Timer Controller, 32 Channels.
Specifications
Output Channels:4, 6, 10, 22 and 32 Channels Available.
Power Requirements:85 to 270 VAC.
Power Consumption:1.2 W.
Solenoid Supply:300 VA.
Fuse:Type 3 AG, 3 A @ 250 VAC.
Temperature Limits:-40 to 140°F (-40 to 60°C).
Storage Temperature Limits:-40 to 176°F (-40 to 80°C).
On Time:50 msec to 500 msec.
On Time Accuracy:±5% of setting.
On Time Stability:±1 msec.
Off Time:1 second to 180 seconds.
Off Time Accuracy:5% of setting.
Weight:9 oz (255 g).
Agency Approvals:CE, cUL, UL.
*Additional Specifications on IOM.
Features
Better synchronized on-time pulse to the power line for better pulse stability
Adjustable potentiometers to select time-on and time-off settings
Simple and easy to use design
Options
L-Mounting Bracket for Field Retrofits (4 thru 10 channel only): 8-1/4″ x 6-1/4″ (209.55 x 158.75 mm)
WP-Weatherproof Housing
Related Products
Series RSV Pilot Solenoid Valve
Series BHC Bulk Head Connectors
Series DCV/RDCV Diaphragm Valve
Series CLS2 Capacitive Level Switch
Series PLS Paddle Level Switch
Series PMT Particulate Transmitter
Series DH3 Digihelic® Differential Pressure Controller
Dwyer DCT604 Timer Controller
Minimum Order Quantity
12 Number
Brand
DWYER USA
Model No.
Dwyer DCT604
Accuracy
5% of setting
Voltage
85 to 270 VAC
Country of Origin
Made in India
Power Consumption
1.2 W
Weight:
9 oz (255 g)
Dwyer DCT604 Timer Controller
Dwyer Instruments DCT604
Timer Controller 4 Channels
Order #: DCT604
Mfg #: DCT604
Register to View Exclusive Member PricingThe Series DCT600 Timer Controller is a timing system for pulse-jet type Dust Collectors or pneumatic conveying systems in either continuous or on-demand cleaning applications. It provides either 4, 6, 10, 22 or 32 channels. The DCT600 was designed for ease of installation in your dust collector system. For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel. Time-on and time-off settings are selected using two potentiometers. High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode. The new enhanced board circuitry of the DCT600 synchronizes the on-time pulse to the power line to achieve a pulse stability of +/- 1 msec. For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line. Availability: Ships in 5-6 weeks Product Highlights
4 Channels
Dwyer DCT600 Series Offers
Features
Available in Either 4, 6, 10, 22 or 32 Channels
Designed for ease of installation in your dust collector system
For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel
Time-on and time-off settings are selected using two potentiometers
High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode
For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line
Functional Specifications
Output Channels: 4, 6, 10, 22 and 32 channels available
Solenoid Supply: 300 VA
Fuse: Type 3 AG, 3 A @ 250 VAC
Temperature Limits: -40 to 140°F (-40 to 60°C)
On Time: 50 msec to 500 msec
On Time Accuracy: ±5% of setting
On Time Stability: ±1 msec
Off Time: 1 second to 180 seconds
Off Time Accuracy: 5% of setting
General Specifications
Power Requirements: 85 to 270 VAC
Power Consumption: 1.2 W
Weight: 9 oz (255 g)
Dwyer DCT622 Timer Controller
Minimum Order Quantity
1 Number
Brand
DWYER USA
Model No.
Dwyer DCT622
Size
Available in Either 4, 6, 10, 22 or 32 Channels
Accuracy
5% of setting
Voltage
85 to 270 VAC
Country of Origin
Made in India
Fuse
Type 3 AG, 3 A @ 250 VAC
Output Channels
4, 6, 10, 22 and 32 channels available
Power Requirements
85 to 270 VAC
Power Consumption
1.2 W
Weight
9 oz (255 g)
Dwyer DCT622 Timer Controller
Dwyer Instruments DCT622
Timer Controller 22 Channels
Order #: DCT622
Mfg #: DCT622
Register to View Exclusive Member PricingThe Series DCT600 Timer Controller is a timing system for pulse-jet type Dust Collectors or pneumatic conveying systems in either continuous or on-demand cleaning applications. It provides either 4, 6, 10, 22 or 32 channels. The DCT600 was designed for ease of installation in your dust collector system. For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel. Time-on and time-off settings are selected using two potentiometers. High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode. The new enhanced board circuitry of the DCT600 synchronizes the on-time pulse to the power line to achieve a pulse stability of +/- 1 msec. For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line. Availability: Ships in 5-6 weeks Product Highlights
22 Channels
Dwyer DCT600 Series Offers
Features
Available in Either 4, 6, 10, 22 or 32 Channels
Designed for ease of installation in your dust collector system
For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel
Time-on and time-off settings are selected using two potentiometers
High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode
For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line
Functional Specifications
Output Channels: 4, 6, 10, 22 and 32 channels available
Solenoid Supply: 300 VA
Fuse: Type 3 AG, 3 A @ 250 VAC
Temperature Limits: -40 to 140°F (-40 to 60°C)
On Time: 50 msec to 500 msec
On Time Accuracy: ±5% of setting
On Time Stability: ±1 msec
Off Time: 1 second to 180 seconds
Off Time Accuracy: 5% of setting
General Specifications
Power Requirements: 85 to 270 VAC
Power Consumption: 1.2 W
Weight: 9 oz (255 g)
Dwyer DCT606 Timer Controller
Minimum Order Quantity
1 Number
Brand
DWYER USA
Model No.
Dwyer DCT606
Size
Available in Either 4, 6, 10, 22 or 32 Channels
Accuracy
5% of setting
Voltage
85 to 270 VAC
Country of Origin
Made in India
Fuse
Type 3 AG, 3 A @ 250 VAC
Output Channels
4, 6, 10, 22 and 32 channels available
Power Requirements
85 to 270 VAC
Power Consumption
1.2 W
Weight
9 oz (255 g)
Dwyer DCT606 Timer Controller
Dwyer Instruments DCT606
Timer Controller 6 Channels
Order #: DCT606
Mfg #: DCT606
Register to View Exclusive Member PricingThe Series DCT600 Timer Controller is a timing system for pulse-jet type Dust Collectors or pneumatic conveying systems in either continuous or on-demand cleaning applications. It provides either 4, 6, 10, 22 or 32 channels. The DCT600 was designed for ease of installation in your dust collector system. For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel. Time-on and time-off settings are selected using two potentiometers. High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode. The new enhanced board circuitry of the DCT600 synchronizes the on-time pulse to the power line to achieve a pulse stability of +/- 1 msec. For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line. Availability: Ships in 5-6 weeks Product Highlights
6 Channels
Dwyer DCT600 Series Offers
Features
Available in Either 4, 6, 10, 22 or 32 Channels
Designed for ease of installation in your dust collector system
For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel
Time-on and time-off settings are selected using two potentiometers
High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode
For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line
Functional Specifications
Output Channels: 4, 6, 10, 22 and 32 channels available
Solenoid Supply: 300 VA
Fuse: Type 3 AG, 3 A @ 250 VAC
Temperature Limits: -40 to 140°F (-40 to 60°C)
On Time: 50 msec to 500 msec
On Time Accuracy: ±5% of setting
On Time Stability: ±1 msec
Off Time: 1 second to 180 seconds
Off Time Accuracy: 5% of setting
General Specifications
Power Requirements: 85 to 270 VAC
Power Consumption: 1.2 W
Weight: 9 oz (255 g)
Dwyer DCT610 Timer Controller
Minimum Order Quantity
1 Number
Brand
DWYER USA
Usage/Application
Dust Collection,Pneumatic Conveying
Rated Voltage
85 to 270 VAC
Model Name/Number
Dwyer DCT610
Keyboard Type
Dwyer DCT610 Timer Controller
Timer Type
Analog
Size
Available in Either 4, 6, 10, 22 or 32 Channels
Weight
9 oz (255 g)
Accuracy
5% of setting
Voltage
85 to 270 VAC
I Deal In
New Only
Country of Origin
Made in India
Fuse
Type 3 AG, 3 A @ 250 VAC
Output Channels
4, 6, 10, 22 and 32 channels available
Power Requirements
85 to 270 VAC
Power Consumption
1.2 W
Dwyer DCT610 Timer Controller
Dwyer Instruments DCT610
Timer Controller 10 Channels
Order #: DCT610
Mfg #: DCT610
Register to View Exclusive Member PricingThe Series DCT600 Timer Controller is a timing system for pulse-jet type Dust Collectors or pneumatic conveying systems in either continuous or on-demand cleaning applications. It provides either 4, 6, 10, 22 or 32 channels. The DCT600 was designed for ease of installation in your dust collector system. For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel. Time-on and time-off settings are selected using two potentiometers. High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode. The new enhanced board circuitry of the DCT600 synchronizes the on-time pulse to the power line to achieve a pulse stability of +/- 1 msec. For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line. Availability: Ships in 5-6 weeks Product Highlights
10 Channels
Dwyer DCT600 Series Offers
Features
Available in Either 4, 6, 10, 22 or 32 Channels
Designed for ease of installation in your dust collector system
For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel
Time-on and time-off settings are selected using two potentiometers
High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode
For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line
Functional Specifications
Output Channels: 4, 6, 10, 22 and 32 channels available
Solenoid Supply: 300 VA
Fuse: Type 3 AG, 3 A @ 250 VAC
Temperature Limits: -40 to 140°F (-40 to 60°C)
On Time: 50 msec to 500 msec
On Time Accuracy: ±5% of setting
On Time Stability: ±1 msec
Off Time: 1 second to 180 seconds
Off Time Accuracy: 5% of setting
General Specifications
Power Requirements: 85 to 270 VAC
Power Consumption: 1.2 W
Weight: 9 oz (255 g)
Dwyer DTC632 Timer Controller
Minimum Order Quantity
1 Number
Brand
DWYER USA
Usage/Application
Dust Collection,Pneumatic Conveying
Rated Voltage
85 to 270 VAC
Model Name/Number
Dwyer DTC632
Timer Type
Analog
Size
Available in Either 4, 6, 10, 22 or 32 Channels
Accuracy
5% of setting
Voltage
85 to 270 VAC
I Deal In
New Only
Country of Origin
Made in India
Fuse
Type 3 AG, 3 A @ 250 VAC
Output Channels
4, 6, 10, 22 and 32 channels available
Power Requirements
85 to 270 VAC
Power Consumption
1.2 W
Dwyer DCT632 Timer Controller
Dwyer Instruments DCT632
Timer Controller 32 Channels
Order #: DCT632
Mfg #: DCT632
Register to View Exclusive Member PricingThe Series DCT600 Timer Controller is a timing system for pulse-jet type Dust Collectors or pneumatic conveying systems in either continuous or on-demand cleaning applications. It provides either 4, 6, 10, 22 or 32 channels. The DCT600 was designed for ease of installation in your dust collector system. For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel. Time-on and time-off settings are selected using two potentiometers. High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode. The new enhanced board circuitry of the DCT600 synchronizes the on-time pulse to the power line to achieve a pulse stability of +/- 1 msec. For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line. Availability: Ships in 5-6 weeks Product Highlights
32 Channels
Dwyer DCT600 Series Offers
Features
Available in Either 4, 6, 10, 22 or 32 Channels
Designed for ease of installation in your dust collector system
For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel
Time-on and time-off settings are selected using two potentiometers
High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode
For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line
Functional Specifications
Output Channels: 4, 6, 10, 22 and 32 channels available
Register to View Exclusive Member PricingThe Series DCT600 Timer Controller is a timing system for pulse-jet type Dust Collectors or pneumatic conveying systems in either continuous or on-demand cleaning applications. It provides either 4, 6, 10, 22 or 32 channels. The DCT600 was designed for ease of installation in your dust collector system. For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel. Time-on and time-off settings are selected using two potentiometers. High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode. The new enhanced board circuitry of the DCT600 synchronizes the on-time pulse to the power line to achieve a pulse stability of +/- 1 msec. For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line. Availability: Ships in 5-6 weeks Product Highlights
32 Channels
Dwyer DCT600 Series Offers
Features
Available in Either 4, 6, 10, 22 or 32 Channels
Designed for ease of installation in your dust collector system
For installations requiring fewer channels than available on the board, a shorting plug (DCT604 & DCT610) or dip switches (DCT622 & DCT632) allows selection of the last used channel
Time-on and time-off settings are selected using two potentiometers
High-limit and low-limit control inputs are provided for use with on-demand systems. Units can also work in continuous clean mode
For safety, the control circuitry including the control inputs and the last channel jumper is isolated from the power line
Functional Specifications
Output Channels: 4, 6, 10, 22 and 32 channels available
-1 to 40 bar /-30 inHg to 600 PSI Pneumatic Pressure and Vacuum
FEATURES
Dual Source Of Pneumatic Pressure and Vacuum.
Fully Portable Hand Operated Unit Supplied as a Complete Kit.
Generating up to 40 bar / 600 PSI Pressure or 96% Vacuum.
Adjustable Stroke To Provide Over Pressure Protection.
Quick fit instruments are Available to Use With The System Including Electronic Calibrators,
Digital Indicators and Analogue Gauges.
The TP1-40 is Supplied in a Light, High Quality Carrying Case, with Adaptors, a Set of Washers, Seals and Provision for Additional Instruments.
The TP1- 40 Pressure Test System has been introduced to complement an already extensive range of Pressure Calibration Products and Can be Used for Calibration Checks on Pressuretransmitters, Pressure Switches, indicators, Recorders and Controllers.
Calibration Checks can be Carried Out Simply by Temporarily Shutting off Line Pressure, Selecting the Digital Indicator or Test Gauge Required and Connecting The Instrument Via The Flexible Hose and Swivel Adaptor to The Pressure Measuring Instrument to Be Checked. The Range of Adaptors Enables Connection to Most Gauge Threads. TP1- 40 Can Be Used as a Portable Pressure Comparator in Conjunction With Various Pressure Indicating Devices. This Precision Unit includes an Adjustable Over Pressure Protection System as Standard. TP1 Specifications
Key:
1. Pressure port – 3/8″ BSP Parallel Female Connection To Take Master Instruments E.G. Digital Or Analogue Gauge, PC6 PRO Calibrator 2. Fine Adjustment Valve. 3. Pressure Release Valve. 4. Pressure / Vacuum Selector 5. Adjustable Stroke for Varying Maximum Pressureoutput (Over Pressure Protection). 6. BSP or NPT Adaptor Set 7. Flexible Hose To Item Under Test. 8. Nylon Seals for BSP Adaptors ( See Seal Kit Provided ) DO NOT Use ”PTFE” Tape For Sealing With Parallel Threads 9. Knurled ‘Quick-Fit’ Connectors 10. Pump Handles Specification
Output Pressure:0 to 40 bar / 0 to 600 psi (Adjustable)
Output Vacuum:96% (0 to -0.960 bar / 0 to -29 in Hg (Adjustable) at 1000 mbar ambient)
-1 to 40 bar /-30 inHg to 600 PSI Pneumatic Pressure and Vacuum
FEATURES
Dual Source Of Pneumatic Pressure and Vacuum.
Fully Portable Hand Operated Unit Supplied as a Complete Kit.
Generating up to 40 bar / 600 PSI Pressure or 96% Vacuum.
Adjustable Stroke To Provide Over Pressure Protection.
Quick fit instruments are Available to Use With The System Including Electronic Calibrators,
Digital Indicators and Analogue Gauges.
The TP1-40 is Supplied in a Light, High Quality Carrying Case, with Adaptors, a Set of Washers, Seals and Provision for Additional Instruments.
The TP1- 40 Pressure Test System has been introduced to complement an already extensive range of Pressure Calibration Products and Can be Used for Calibration Checks on Pressuretransmitters, Pressure Switches, indicators, Recorders and Controllers.
Calibration Checks can be Carried Out Simply by Temporarily Shutting off Line Pressure, Selecting the Digital Indicator or Test Gauge Required and Connecting The Instrument Via The Flexible Hose and Swivel Adaptor to The Pressure Measuring Instrument to Be Checked. The Range of Adaptors Enables Connection to Most Gauge Threads. TP1- 40 Can Be Used as a Portable Pressure Comparator in Conjunction With Various Pressure Indicating Devices. This Precision Unit includes an Adjustable Over Pressure Protection System as Standard. TP1 Specifications
Key:
1. Pressure port – 3/8″ BSP Parallel Female Connection To Take Master Instruments E.G. Digital Or Analogue Gauge, PC6 PRO Calibrator 2. Fine Adjustment Valve. 3. Pressure Release Valve. 4. Pressure / Vacuum Selector 5. Adjustable Stroke for Varying Maximum Pressureoutput (Over Pressure Protection). 6. BSP or NPT Adaptor Set 7. Flexible Hose To Item Under Test. 8. Nylon Seals for BSP Adaptors ( See Seal Kit Provided ) DO NOT Use ”PTFE” Tape For Sealing With Parallel Threads 9. Knurled ‘Quick-Fit’ Connectors 10. Pump Handles Specification
Output Pressure:0 to 40 bar / 0 to 600 psi (Adjustable)
Output Vacuum:96% (0 to -0.960 bar / 0 to -29 in Hg (Adjustable) at 1000 mbar ambient)
TP1- 40 :Hand Held Pressure Test System in Rigid Carrying Case With 1 Metre Flexible Hose and Adaptor Set
PC6, PC6-PRO,:A Range of Pressure Calibrators Available Between -1 and 40 bar / -30 inHg and 600 psi
PC6-IS, PC6-AV
DTG-2K :A Range of Digital Indicators up to 30 bar (450psi)
TPG Range: A Range of Analogue Gauges Between -1 and 40 bar / -30 inHg and 600 psi
TPK1 :Service Kit Containing a set of seals. ”O” rings, retaining screws and allen key
LTPA-BSP-QF:Set of 7 BSP ‘quick-fit’ adaptors
LTPA-NPT-QF:Set of 6 NPT ‘quick-fit’ adaptors
SI Pressure TP1-40-K Pneumatic Hand Pump Kit
Minimum Order Quantity
1 Piece
Brand
SI PRESSURE INSSTRRUMENTS
Part Number
TP1-40-K
Material
Stainless Steel
Model Name/Number
TP1-40-K
Usage/Application
Industrial
Country of Origin
Made in India
SI Pressure TP1-40-K Pneumatic Hand Pump Kit
SI Pressure TP1-40-K Pneumatic Hand Pump Kit provide -28 in Hg Vacuum to 600 psi DESCRIPTION
The SI Pressure TP1-40-K Pneumatic Hand Pump Generates Pressure up to 600 psi or -28″Hg. Made With No Plastic Parts, SI Pressure TPI1-40-K Pneumatic Hand Pumps are designed to endure harsh environments unlike the competition’s disposable models.
The Hand-Held SI Pressure TP1-40-K Pneumatic Hand Pump Supplies Pressure and Vacuum Generation with exceptional fine-tuning adjustments or stroke adjustments. These Hand Pumps are ideal for use with electronic calibrators, Digital indicators, Analog Gauges, Pressure Transmitters, transducers, relief valves, or similar instrumentation. The Rugged and Reliable Design of the SI Pressure TP1-40-K Pneumatic Hand Pump assures no leaks. With the fewest strokes to maximum pressure, SI Pressure TP1-40-K Pneumatic Hand Pumps are the most efficient hand pumps on the Market with the Fewest Strokes to Maximum Pressure. MORE INFORMATION
Weight : 2.000000
Product Includes : Hand Pump, Hose, Fittings, and Carrying Case
Specifications
Output Pressure: 0 to 600 psi (Adjustable)
Output Vacuum: 0 to -29 in Hg (Adjustable) at 1000 mbar ambient)
The Series PCHP Pneumatic Hand Pump comfortably sources pressure and vacuum to check calibration of gages, switches, transmitters, and recorders. The contoured cushion handles provide extra comfort while preventing the pump from sliding. The oversized check valve provides smooth operation throughout the output range. The dual o-rings on all pistons ensure zero leakage.
Other Details:
Model Description
PCHP-1 Pneumatic Hand Pump, Range 600 psi. PCHP-1K Pneumatic Hand Pump, Range 600 psi, with hose kit.PCHP-HK High Pressure Hose For PCHP-1 Hand Pump.
Pneumatic Hand Pump
Minimum Order Quantity
1 Number
Brand
SI PREESSURE INSTRUMENTS
Material
Stainless Steel
Model Name/Number
TP1-40
Pump Type
Pneumatic Hand Pump
Output
0 to 40 bar / 0 to 600 psi (Adjustable)
Country of Origin
Made in India
Output Vacuum
96% (0 to -0.960 bar / 0 to -29 in Hg (Adjustable) at 1000 mbar ambient)
-1 to 40 bar /-30 inHg to 600 PSI Pneumatic Pressure and Vacuum
FEATURES
Dual Source Of Pneumatic Pressure and Vacuum.
Fully Portable Hand Operated Unit Supplied as a Complete Kit.
Generating up to 40 bar / 600 PSI Pressure or 96% Vacuum.
Adjustable Stroke To Provide Over Pressure Protection.
Quick fit instruments are Available to Use With The System Including Electronic Calibrators,
Digital Indicators and Analogue Gauges.
The TP1-40 is Supplied in a Light, High Quality Carrying Case, with Adaptors, a Set of Washers, Seals and Provision for Additional Instruments.
The TP1- 40 Pressure Test System has been introduced to complement an already extensive range of Pressure Calibration Products and Can be Used for Calibration Checks on Pressuretransmitters, Pressure Switches, indicators, Recorders and Controllers.
Calibration Checks can be Carried Out Simply by Temporarily Shutting off Line Pressure, Selecting the Digital Indicator or Test Gauge Required and Connecting The Instrument Via The Flexible Hose and Swivel Adaptor to The Pressure Measuring Instrument to Be Checked. The Range of Adaptors Enables Connection to Most Gauge Threads. TP1- 40 Can Be Used as a Portable Pressure Comparator in Conjunction With Various Pressure Indicating Devices. This Precision Unit includes an Adjustable Over Pressure Protection System as Standard. TP1 Specifications
Key:
1. Pressure port – 3/8″ BSP Parallel Female Connection To Take Master Instruments E.G. Digital Or Analogue Gauge, PC6 PRO Calibrator 2. Fine Adjustment Valve. 3. Pressure Release Valve. 4. Pressure / Vacuum Selector 5. Adjustable Stroke for Varying Maximum Pressureoutput (Over Pressure Protection). 6. BSP or NPT Adaptor Set 7. Flexible Hose To Item Under Test. 8. Nylon Seals for BSP Adaptors ( See Seal Kit Provided ) DO NOT Use ”PTFE” Tape For Sealing With Parallel Threads 9. Knurled ‘Quick-Fit’ Connectors 10. Pump Handles Specification
Output Pressure:0 to 40 bar / 0 to 600 psi (Adjustable)
Output Vacuum:96% (0 to -0.960 bar / 0 to -29 in Hg (Adjustable) at 1000 mbar ambient)
TP1- 40 :Hand Held Pressure Test System in Rigid Carrying Case With 1 Metre Flexible Hose and Adaptor Set
PC6, PC6-PRO,:A Range of Pressure Calibrators Available Between -1 and 40 bar / -30 inHg and 600 psi
PC6-IS, PC6-AV
DTG-2K :A Range of Digital Indicators up to 30 bar (450psi)
TPG Range: A Range of Analogue Gauges Between -1 and 40 bar / -30 inHg and 600 psi
TPK1 :Service Kit Containing a set of seals. ”O” rings, retaining screws and allen key
LTPA-BSP-QF:Set of 7 BSP ‘quick-fit’ adaptors
LTPA-NPT-QF:Set of 6 NPT ‘quick-fit’ adaptors
SI Pressure Instruments TP1-40-K
Minimum Order Quantity
1 Number
Usage/Application
Calibration
Display Type
Analog
Color
Black
Brand
SI PREESSURE INSTRUMENTS
Packaging Type
1 BOX
Country of Origin
Made in India
SI Pressure Instruments TPI-40-K
Hand-Held Pressure Or Vacuum Generation
Low-Cost Way To Verify Performance Of Pressure Instrumentation
Rugged and Reliable Design
Fine Adjustment Control
The Most Efficient Pumps Available
Specifications & Description
Description(SI Pressure) TP1 Pneumatic Pump Kit, Vacuum to 600 psi
MORE ABOUT THIS ITEM
These Pumps Are Ideal for use With Electronic Calibrators, Digital Indicators, Analog Gauges, Pressure Transmitters, Transducers, Relief Valves, or similar instrumentation. The rugged and reliable design of these pumps and the fine adjustment controls added to their design provides a low cost way to verify the performance of pressure instrumentation. Pumps can be purchased independently, or in a kit including carrying case, NPT adapters, seals and hoses. The SHTP1 hydraulic pump is currently the only hand pump capable of generating pressure up to 15,000 psi, utilizing hydraulic oil, Skydrol or distilled water. The pump includes a unique high pressure or priming selector on the scissor action pump mechanism, making pressure generation above 5,000 psi easier. The STP1 pneumatic pump generates pressure to 600 psi and vacuum to 28”Hg on the same unit. Made with no plastic parts these pumps are designed to endure harsh environments unlike our competitor’s disposable models. The SLTP1 pneumatic pump also acts as a dual source of pressure and vacuum over smaller ranges making very fine adjustments easier. The SLTP1 range is 25”Hg vacuum to 30 psi, with 0.00145 psi sensitivity.
Pressure Test System TP1-40
Minimum Order Quantity
1 Piece
Material
Stainless Steel
Brand
SI PREESSURE INSTRUMENTS
Country of Origin
Made in India
Output Pressure
0 to 40 bar / 0 to 600 psi (Adjustable)
Output Vacuum
96% (0 to -0.960 bar / 0 to -29 in Hg (Adjustable) at 1000 mbar ambient)
-1 to 40 bar /-30 inHg to 600 psi Pneumatic Pressure and Vacuum
FEATURES
Dual source of pneumatic pressure and vacuum.
Fully portable hand operated unit supplied as a complete kit.
Generating up to 40 bar / 600 psi pressure or 96% vacuum.
Adjustable stroke to provide over pressure protection.
Quick fit instruments are available to use with the system including electronic calibrators,
digital indicators and analogue gauges.
The TP1-40 is supplied in a light, high quality carrying case, with adaptors, a set of washers, seals and provision for additional instruments.
The TP1- 40 Pressure Test System has been introduced to complement an already extensive range of pressure calibration products and can be used for calibration checks on pressuretransmitters, pressure switches, indicators, recorders and controllers. Calibration checks can be carried out simply by temporarily shutting off line pressure, selecting the digital indicator or test gauge required and connecting the instrument via the flexible hose and swivel adaptor to the pressure measuring instrument to be checked. The range of adaptors enables connection to most gauge threads. TP1- 40 can be used as a portable Pressure Comparator in conjunction with various pressure indicating devices. This precision unit includes an adjustable over pressure protection system as standard. TP1 Specifications
Key:
1. Pressure port – 3/8″ BSP Parallel female connection to take master instruments e.g. digital or analogue gauge, PC6 PRO Calibrator2. Fine adjustment valve.3. Pressure release valve.4. Pressure / Vacuum selector5. Adjustable stroke for varying maximum pressureoutput (over pressure protection).6. BSP or NPT adaptor set7. Flexible hose to item under test.8. Nylon seals for BSP adaptors ( see seal kit provided )DO NOT use ‘PTFE’ tape for sealing with parallel threads9. Knurled ‘quick-fit’ connectors10. Pump Handles Specification
Output Pressure:0 to 40 bar / 0 to 600 psi (Adjustable)
Output Vacuum:96% (0 to -0.960 bar / 0 to -29 in Hg (Adjustable) at 1000 mbar ambient)