Differential Pressure Indicator

Rs 9,500 / Piece

Model NumberADPI
BrandAerosense
ApplicationIndustrial
Usage/ApplicationPharma Cleanrooms
ConnectionNew
Scale Range4 digits
Accuracy0.5%
Application/UsageHVAC
Display TypeRed LED 7 segment Display
ConditionNew
Modbus communicationRS-485
Output range4-20mA

Differential Pressure Indicator

Our firm offers a high-quality range of Aerosense Differential Pressure Indicator/Transmitter.

Features:

  • Panel mount/Rectangular type cut out
  • Built in High and Low Buzzer Alarm for process set parameter
  • Violation with Acknowledgement key


Applications:

  • Pharma Cleanrooms
  • HVAC
  • Environmental
  • Pharma Machinery
  • Across Filters
  • Hospital Violation Rooms
  • Operation Theaters & Laboratories


Advantages:

  • Precision of measurement in HVAC duct pressure application makes this instrument suitable for optimization of energy & thereby its conversation is ventilation systems
  • Analog Output & RS-485 Communication lead to easy integration with Variable frequency drives & SCADA/BMS



Additional Information:

  • Item Code: ADPI

Aerosense Differential Pressure Switch

Rs 1,350 / Piece

Power/Voltage0.11 A/250 VAC
Usage/ApplicationFan, Blower and filter monitoring
BrandAEROSENSE
Use ForGas
ConditionNew
Media TypeGas
Ambient Temperature-20 to 60 degree C
ModelPS-200
ApplicationsPressure and Flow monitoring
Product ApplicationsValve and damper monitoring

Aerosense Differential Pressure Switch

Series PS Differential Pressure Switch With dual scale field adjustable Set Point Knob

The Series PS Differential Pressure Switch is designed for pressure, vacuum and differential pressure. The dual scaled adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

  • Fan, Blower and filter monitoring
  • Pressure and Flow monitoring
  • Valve and damper monitoring

Technical Data

  • Service: Air & non aggressive gases
  • Material: ABS
  • Electrical Connection: 3 Screw terminal
  • Cable Entry: M16
  • Pressure Connection: Male 0 5 MM
  • Weight: 150 gms
  • Operation Temperature: -20 to 60° C
  • Storage Temperature: -40 to 85° C
  • Maximum Pressure: 50 kPA
  • IP Protection: IP54

Optional Accessories

  • 2 Fixing Screws
  • 2 Plastic duct connectors
  • 2 m tube 0 4/7 mm
  • Metallic duct connectors



Additional Information:

  • Item Code: PS-200

Aerosense Series CMT-100 Carbon Monoxide Transmitter

Rs 25,000 / Piece

Packaging Size1
UsageGarage Ventilation
BrandAEROSENSE
Product ApplicationsVehicle maintenance facility.
Response TimeWithin 5 minutes
Power Input24VAC

Aerosense Series CMT-100 Carbon Monoxide Transmitter

Series CMT-100 Carbon Monoxide Transmitter

Series CMT-100, Carbon Monoxide Transmitter designed to detect Carbon Monoxide gas in air with analog and RS-485 MODBUS output. Measurement range is upto 250 ppm and optional 300 ppm is available. It is 3-wired supporting and gives current, voltage and RS-485 MODBUS output.

Product Applications:

  • Garage Ventilation
  • Vehicle maintenance facility.
  • Pre-Calibrated
  • Convenient use with varying voltage application.
  • Easily installed at a low cost when used with exclusive case Semiconductor use to measure CO levels.
  • Provides output signal proportional to CO level Model available to interact with other Devices Optimum for parking lot, tunnel & under Ground places
  • General Performance
  • Operating Temperature: -10 to 50°C
  • Operating Humidity: 10-95% RH (Non-Condensing)
  • Storage Temperature: -30 to 60°C
  • Storage Humidity: 0-95% RH (Non-Condensing)
  • Operating Environment:
    • Residential
    • Commercial spaces
    • CO Measurement
    • Sensing Method
    • Semiconductor
  • Measurement range: 0-250 PPM
  • Coverage Area: 4000 to 6000 sq. ft. typical
  • Accuracy:
    • @23°C, 50% RH
    • 0-100 ppm: +10% FS
    • 100-250 ppm: +10% FS
  • Response Time: Within 5 minutes
  • Warm – up time: 2 hours
  • Electrical Data
  • Power Input: 24VAC
  • Output Signal
  • Voltage Output: 2-10 VDC
  • Current Output: 4-20 mA

Aerosense Series CDT-100 Carbon Dioxide Transmitter

Rs 18,500/ Piece

Display TypeDigital
ModelSeries CDT-100
BrandAEROSENSE
Place Of Origindelhi
Reponse Time150 seconds
ApplicationDemand Control Ventilation in schools,office buildings,hospitals and other indoor environments.
ConditionNew

Aerosense Series CDT-100 Carbon Dioxide Transmitter

Series CDT-100 Carbon Dioxide Transmitter

Series CDT-100, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements.

Measurement range upto 10000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • RS-485 MODBUS output: (4-wired) Modicon MODBUS RTU mode, which follow Modicon Modbus protocol-settable address ID switch
  • Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch
  • Power: 24VDC, AC
  • Size: 123mmX70mmX43mm
  • Operating Temperature: -10 to 60˚C For -CS Models: -40 to 40˚C
  • Operating Humidity range: 0 to 95% RH
  • Storage temperature: -30 to 70˚C
  • Storage temperature for cold storage: -40 to 70˚C
  • Measurement range: 0 to 2000/ 3000/ 5000/ 10000 ppm (Selectable by Jumper)
  • Accuracy: ±30ppm ±3%
  • Response time: 150 seconds
  • Response time for cold storage: 70 seconds
  • Sampling interval: 3 sec
Model No.Specifications
CDT-100Carbon Dioxide Transmitter
CDT-100-LCDCarbon Dioxide Transmitter with display
CDT-100-CSCarbon Dioxide Transmitter for cold storage
CDT-100-CS-LCDCarbon Dioxide Transmitter for cold storage with display
CDT-100-M

Carbon Dioxide Transmitter with MODBUS Communication

CDT-100-M-LCD

Carbon Dioxide Transmitter with MODBUS Communication & display

Aerosense Series ECMT200 Carbon Monoxide Transmitter

Rs 7,500 / Piece

Display TypeDigital
Model NumberSeries ECMT200
BrandAEROSENSE
Place Of Origindelhi
Weight0.28 lb (0.11 kg)
ConditionNew

Aerosense Series ECMT200 Carbon Monoxide Transmitter

Series ECMT200 Carbon Monoxide Transmitter

Series ECMT200, Carbon Monoxide Transmitter provides a field selectable current or voltage output that is proportional to the gas concentration in underground parking garages, vehicle maintenance facilities or mechanical rooms. Measurement range is upto 200 ppm. A field replaceable electrochemical sensor provides accurate readings upto 4 years.

Product Applications:

  • Garage Ventilation
  • Mechanical room monitoring
  • Sensor: Field replaceable electrochemical, 4 year typical lifespan. Range: 0 to 200 ppm.
  • Output Drift: <5% per year in air.
  • Coverage Area: 5000 to 7000 sq. ft. typical.
  • Accuracy: ±2% of reading at the time of calibration.
  • Temperature Limits: -4 to 122°F (-20 to 50°C).
  • Storage Temperature: For best sensor life, 32 to 68°F (0 to 20°C). Humidity Limits: 15 to 90% RH constant; 0 to 99% RH intermittent. Response Time: <45 seconds to 90% of final value.
  • Calibration: 15 turn span and zero adjustment potentiometers. Housing: UV resistant polycarbonate.
  • Output: Jumper selectable 4 to 20 mA (loop powered) or 2 to 10 V (load must be >50 KQ).
  • Power Requirements:
    • Current Output: 18 to 28 VDC;
    • Voltage Output: 18 to 28 VDC/VAC, reverse polarity protected.
  • Electrical Connection: Removable terminal block, includes two PG11and one PG 16 knockouts for conduit fitting.
  • Weight: 0.28 lb (0.11 kg)


Digital Differential Pressure Control – Series A4

Rs 1,500 / Piece

BrandSensocon USA

Digital Differential Pressure Control – Series A4

The Series A4 digital differential pressure controller is a patented microprocessor based pressure controller for positive, negative, and differential pressure as well as velocity and flow. The Series A4 differential pressure controller includes (2) 8A SPDT relays and an associated programming menu that allows full configuration of variables such as setpoints, dead band, engineering units, flow coefficients, and more. The programming is done from a user friendly menu on the OLED display or uploaded using an Opti-Link™ programming key. The OLED also displays the exact setpoints or other user defined variables during normal operation. Furthermore, the menu structure can be customized by moving variables to different menu levels to accommodate many applications. Compared to other mechanical products, the Series A4 digital differential pressure controller has a significantly reduced depth, an improved look, and better performance at a similar price.

Customizing Options Available

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
 
×

Powered by WhatsApp Chat

×