Elementor #2070

Battery Powered Temperature Indicator

Rs 2,500 / Piece

Usage/Application Provides local temperature indication in areas without power availability
Weight 6.0 oz (170 g).
Brand DWYER USA
Condition New
Model Series-BPI
Power Requirements 3.6 V AA lithium metal battery, included, user replaceable.
Battery Life 2 years.
Display 0.3″ (7.6 mm) 4-digit LCD.
Resolution 0.1 Degree C.
Ambient Operating Temperature 14 to 158 Degree F (-10 to 70 Degree C).
Storage Temperature 4 to 185 Degree F (-20 to 85 Degree C).
Front Panel Protection NEMA 4X (IP66).

Battery Powered Temperature Indicator

The Series BPI Battery Powered Indicator accepts RTD or Thermocouple input and provides local or remote display of temperature measurements. Quickly navigate the menu system to customize for each application. Three push buttons allow the user to select input type, engineering units (°F or °C), offset temperature, decimal point position, and password protection. The indicator is housed in a polycarbonate NEMA 4X (IP66) enclosure for additional protection from the environment.

Features:

  • Programmable input type, engineering units (°F/°C), offset temperature, decimal point position, and password protection
  • Four-digit segmented display

Applications:

  • Provides local temperature indication in areas without power availability

 

Installation:
Configuration:
Fit the battery as described in Battery section, then follow the simple configuration menus printed on the reverse side of this sheet. This procedure can be performed with or without the sensor connected. Fit the correct units legend to the front panel face.

Enclosure:
The case offers various options for sensor entry. Please refer to the data sheet for further details. The sensor may be fixed directly to the housing, or remotely connected using cable and gland. Cable length must be no greater than 20 meters to comply with CE certification. All external cabling/sensor entries must maintain IP67 rating.

Additional Information:

  • Item Code: Series-BPI
 

Digital Indicating Transmitter

Rs 8,700 / Piece

Power Requirement 20 to 35 VDC.
Operating Temp -6 to 140 Degree F (-20 to 60 Degree C)
Application Electrically isolates pressure and level transmitters from unregulated circuits for intrinsically sa
Applications Electrically isolates pressure and level transmitters from unregulated circuits for intrinsically sa
Condition New
Brand DWYER USA
Humidity 5 to 95% RH.
Storage Temperature -40 to 176 Degree F (-40 to 80 Degree C).
Model Number Series-MTL5541
Automation Grade Manual
Weight 150 g.
LED Indicator Green Power Indication.

Digital Indicating Transmitter

The SERIES MTL5541 Galvanic Barrier provides intrinsically safe isolation for communication with Dwyer® transmitters approved for use in hazardous areas. This galvanic barrier eliminates the need for a high integrity earth ground required when using shunt type diode type safety barriers. DIN rail mounting and plug-in signal and power connectors simplify installation and maintenance.

Features:

  • Designed to mount on most standard DIN rails
  • Approved for use in hazardous areas


Specification:

  • Hazardous Area Input : Signal range: 0 to 24 mA (including over-range); Transmitter voltage: 16.5 V at 20 mA.
  • Safe Area Output : Signal range: 4 to 20 mA; Under/over-range: 0 to 24 mA;Load resistance: 0 to 360Ω @ 24 mA, or 0 to 450Ω @ 20 mA; Current sink: 600Ω max.; Maximum Voltage Source: 24 VDC; Output resistance: > 1 MΩ.
  • Response Time : Settles to within 10% of final value within 50 µs.
  • Current Consumption (20 mA signal) : 51 mA @ 24V.
  • Maximum Power Dissipation (20 mA signal) : 0.7 W @ 24 VDC, 1.0 W @ 24 VDC.
  • Isolation : 250 V RMS, tested at 1500 V RMS minimum, between safe- and hazardous-area terminals; 50 V between safe-area circuits and power supply.
  • Transfer Accuracy at 68°F (20°C) : Better than 15 µA.
  • Temperature Drift : < 0.8µA/°C.
  • Mounting : T-section 35mm DIN rail (7.5 or 15mm) to EN 50022.
  • Terminals : Accommodate up to 2.5 mm2 stranded or single-core.
  • Safety Description : Vo= 28 V, Io= 93 mA, Po= 651mW, Um= 253 RMS or DC.

Applications:

  • Electrically isolates pressure and level transmitters from unregulated circuits for intrinsically safe applications

Additional Information:

  • Item Code: Series-MTL5541
 

Indicating Alarm Annunciator

Rs 2,650 / Piece

Usage/Application Tank level monitoring
Model No. Series-AN2
Brand DWYER USA
Weight 9.6 oz (272 g).
Application Water and wastewater panels
Ambient Operating Temperature -40 to 149 Degree F (-40 to 65 Degree C).
Mounting 1/8 DIN.
Housing Material UL rated 94V-0 high impact plastic.
Enclosure Rating NEMA 4X (IP65) front panel.
Power Consumption 20 W (6 W on low voltage models).

Indicating Alarm Annunciator

The Series AN2 Indicating Alarm Annunciator provides visible and audible alarms for up to eight inputs. The annunciator also has two SPDT relay outputs that can be used to initiate external alarms, buzzers, or paging devices. The Integral 24 VDC power supply can power most level, temperature, pressure, and flow switches. Audible alarm conditions can be acknowledged, reset, or silenced either via the front panel push buttons or the rear terminal block. The Series AN2 can be set to any common ISA sequences including First-Out.

Features: 

  • Includes integral 24 VDC power supply to power most switches
  • Can be set to any common ISA sequences


Specification:

  • Inputs : NO or NC switches, Open Collector Transistor (Open circuit voltage = 3.3 VDC); Logic Levels: LO = 0 to 0.9 VDC, HI = 2.4 to 28 VDC (100 KΩ input impedance).
  • Outputs : Two SPDT relay (3 A @ 250 VAC or 30 VDC, resistive; 1/14 HP @ 125/250 VAC, inductive).
  • Power Requirements : 85 to 265 VAC 50/60 Hz, 90 to 265 VDC; 12 to 36 VDC, 12 to 24 VAC (depending on model).

Applications:

  • Water and wastewater panels
  • Tank level monitoring
  • Temperature monitoring process

Other Details:

Model Number of Outputs Power Supply
AN24-1 4 85 to 265 VAC
AN24-2 4 12 to 36 VDC
AN28-1 8 85 to 265 VAC
AN28-2 8 12 to 36 VDC

 

Additional Information:

  • Item Code: Series-AN2

 

 

Miniature Current Switch

Rs 6,400 / Piece

Weight 0.5 oz (14.5 g).
Application BAS
Model No. Series-MCS
Brand DWYER USA
Amperage Range MCS-111050 0.5 to 50 A AC continuous; MCS-111001 0.01 to 1 A AC continuous.
Output Rating Isolated, N.O. 0.3 A 130 V DC/AC.
Hysteresis 1%.
Response Time 200 ms.
Temperature Limits 32 to 122 Degree F (0 to 50 Degree C).
Humidity 10 to 95% RH (non-condensing).
Enclosure Rating UL 94V-0 flammability rated ABS, insulation class 600 V.

Miniature Current Switch

The SERIES MCS Miniature Current Switches are ideal for monitoring the current usage in fuse boxes and small control panels. Both models have adjustable set points and LED indication to show there is power to the unit and when the switch activates. Set points can be adjusted using the potentiometer next to the LED’s. Due to the size of the switch, it is only offered in solid core and no core versions. The no core version has terminal blocks which can accept currents up to 1 A directly into the unit.

Features: 

  • Integral mounting flange for quick installation
  • Compact size fits in any space

Applications:

  • BAS
  • HVAC.

 

Other Details:

Model Case Set Point Minimum Set Point (A) LED
MCS-111050 Solid core Adjustable 0.5 Red/geen
MCS-111001 No core (terminal connection) Adjustable 0.01 Red/geen

Additional Information:

  • Item Code: Series-MCS

Series SCS Current Switch

Rs 3,250 / Piece

Brand Dwyer Usa
Temperature Range 5 to 140 Degree F (-15 to 60 Degree C).
Condition New
Model Series-SCS
Application BAS
Frequency 50/60 Hz.
Place Of Origin DELHI
Output Isolated, 1 A 30 VAC/DC max, NO.
External Relay SPST N.O., 10A at 260 VAC (5A at 30 VDC).
Power None, self-powered.
Isolation Voltage 600 VAC RMS.
Enclosure Rating UL, 94 V-O flammability rated, ABS plastic housing.

Series SCS Current Switch

The Series SCS Low Cost Current Switches are ideal for monitoring whether fans, pumps, or motors are operating. The current flowing through the core of the device powers the circuit without an external power supply. All models have a built in solid state output and are easy to install. Optional LED’s and 10 Amp relay modules are available. The Series SCS is available in both Split and Solid Core configurations.

Features:

  • Integral mounting flange for quick installation
  • Solid core or split core configurations


Applications:

  • BAS
  • HVAC

Other Details:

Model Case Amperage Range Set Point Switch Mode Snap-on Relay
SCS-120025 Solid .25 to 200 A 0.25 fixed Under No
SCS-111100 Solid 1 to 135 A Adjustable Over/under No
SCS-111100-R Solid 1 to 135 A Adjustable Over/under Yes
SCS-220015 Split .15 to 200 A 0.15 fixed Under No
SCS-220150 Split 1.5 to 200 A 1.5 fixed Under No
SCS-211125 Split 1.25 to 135 A Adjustable Over/under No
SCS-220150-R Split 1.5 to 200 A 1.5 fixed Under Yes
SCS-211125-R Split 1.25 to 135 A Adjustable Over/under Yes

Additional Information:

  • Item Code: Series-SCS

Vibration Transmitter

Rs 24,500 / Piece

Brand DWYER USA
Temperature Range -22 to 221 Degree F (-30 to 105 Degree C).
Application Industrial
Weight 0.28 lb (0.125 kg)
Model No Model-VBT-1
Condition New
Usage/Application Motors
Enclosure Rating NEMA 6 (IP68).
Housing Material 316 SS.
Electrical Rating 9.6 to 32 VDC.
Frequency Range 10 to 1000 Hz.
Output Signal 4 to 20 mA.

Vibration Transmitter

The Model VBT-1 Vibration Transmitter continuously detects the vibration in a system and monitors for unusual operating conditions and potential failure. The vibration is converted into an analog signal at the current output. The VBT requires no setup, and there is no software required for configuration. The 2-wire loop power operation, combined with standard M12 micro cable connector and interchangeable mounting studs (1/4″-28 UNF/M8 (2) or the 1/4″-28 UNF), makes for a fast and reliable installation.

Features:

  • Easy set-up and operating concept
  • Stainless steel housing
  • No software required

Specification:

  • Accuracy : < ±3%.
  • Connections : M12 connector.
  • Mounting Orientation : Any position.
  • Nonlinearity : < ±0.25% of span.
  • Repeatability : < 0.5%.

Applications:

  • Motors
  • Pumps
  • Fans
  • Engines
  • Compressors
  • Gear boxes

Additional Information:

  • Item Code: Model-VBT-1
 

Series CCS Current Switch

Rs 1,850 / Piece

Model Number Series-CCS
Temperature -22 to 158 Degree F (-30 to 7 Degree C).
Humidity 0 to 95% (non-condensing).
Application/Usage BAS
Condition New
Brand DWYER USA
Connection New
Frequency 40 to 400 Hz.
Usage/Application HVAC
Amperage Range 0 to 200 A AC.
Output Normally open, NPN.
Isolation Voltage 2000 V.
Enclosure Rating UL, 94 V-O flammability rated, ABS plastic housing.

Series CCS Current Switch

The SERIES CCS Current Switches are ideal for monitoring the operating status of fans, pumps, and motors. These self-powered switches can be hung or tied directly to cables or wires. For use on existing installations, split core models can be installed without disconnecting cables. LED indicators provide a visual confirmation that the current is flowing through the core. Both fixed and adjustable set points are available. The adjustable models utilize a potentiometer to easily adjust the set point.

Features:

  • Integral mounting flange for quick installation
  • Solid core or split core configurations
  • LED Indicator
  • Maximum Switch Rating : For fixed set point models: 0.3 A @ 135 VAC/DC; For adjustable set point models: 1 A @ 240 VAC.

Applications:

  • BAS
  • HVAC

 

Other Details:

Model Case Set Point Minimum Set Point (A) LED Dry Contact Output
CCS-121050 Solid core Fixed 0.50 (±0.2) Red Yes
CCS-111100 Solid core Adjustable 1.00 (±0.2) Red/green No
CCS-221100 Split core Fixed 1.00 (±0.2) Red Yes
CCS-211150 Split core Adjustable 1.50 (±0.2) Red/green No
CCS-131100 Solid core Adjustable 1.00 (±0.2) Red/green Yes
CCS-231150 Split core Adjustable 1.50 (±0.2) Red/green Yes

Additional Information:

  • Item Code: Series-CCS

Bar Graph Meter

Rs 8,500 / Piece

Model Series-BGM
Accuracy +/-0.05% FS.
Condition new
Storage Temperature -67 to 176 Degree F (-55 to 80 Degree C).
Usage Laboratory
Weight 40 oz (1.13 kg)
Operating Temperature 13 to 176 Degree F (-25 to 80 Degree C)
Brand DWYER USA
Enclosure Rating NEMA 1 or NEMA 4Xt model dependent IP65 front.
Decimal Point 3 positions, user selectable.
Outputs 2 SPST relay outputs (optional).
Time Delay 0.5 S
Input Range 0 to +/-10 VDC or 4 to 20 mA.

Bar Graph Meter

The Series BGM Digital Bar Graph Meter is extremely durable and can replace a wide range of analog meters. The 4-digit display will significantly reduce the potential for human error in reading by eliminating errors commonly produced by the viewing angle when reading analog meters. This series has a key pad that allows for easy access of features without complex menu structures. With the combined ability to create a wide range of custom faceplate and the optional NEMA 4X bezel, the Series BGM can be used in a variety of applications. The LED bar graph adds a visual indicator of the measured value so that it can be visually analyzed, preventing accidents or system failures from happening.

Features: 

  • Bar graph visual indicator
  • High resolution for better precision
  • Many configurable options to design a meter for any need


Specification:

  • Power Requirements : 120 VAC 50/60 Hz, 5 to 12 VDC, or 10 to 30 VDC model dependent.
  • Power Consumption : 120 VAC: 2.4 W @ 20 mA max; 5 to 12 VDC: 1.2 W @ 100 mA max; 10 to 30 VDC: 1.5 W @ 50 mA max.
  • Display : LED Display: 4 red colored digits, 0.3″ height; LED Graph: 31 element bar, 0.2″ W x 3.1″ L (5.08 mm W x 78.74 mm L).
  • Electrical Connections : Removable screw terminal blocks.
  • Switch Rating : 1 A @ 200 V.
  • Enclosure Material : Bezel: Black epoxy enameled steel; Window: Acrylic; Case and Mounting Bracket: 304 SS.

Applications:

  • Visual location and indication of flow, level or air velocity

Additional Information:

  • Item Code: Series-BGM
 

Digital Timer / Tachometer / Counter

Rs 750 / Piece

Operating Temp. 32 to 122 Degree F (0 to 50 Degree C).
Humidity 35 to 85% RH (non-condensing).
Application Industrial
Weight 4 oz (114 g).
Model Number Series-LCT216
Display Type Digital
Brand DWYER USA
Condition New
Reset Time 0.001 S. minimum.
Power Requirements 100 to 240 VAC 50 / 60 Hz.
Power Consumption Less than 10 VA.
Internal Power Supply 12 VDC +/-10%, 100 mA.

Digital Timer / Tachometer / Counter

The Series LCT216 combines a versatile timer, counter, and tachometer in one device. The bright, easy-to-read display shows both the desired set point and the current process value as well as the operating mode that the control is functioning in. The fourteen pre-programmed timer functions are easy to set up and cover most applications. The counting functions include one stage or two stage counting along with batch, total, or dual counting modes. The Series LCT216 can also be used as a tachometer to measure rotational speeds. For quick set up, many of the programming parameters can be set with external dip switches located on the side of the unit.

Features: 

  • Fourteen pre-programmed timer functions
  • One stage, two stage, batch, total, and dual counting modes


Specification:

  • Control Output Ratings : (Out 1) Relay: SPST 5A at 250 VAC, Transistor: NPN Open collector 100 mA / 30 VDC residual voltage = 1.5 VDC max; (Out 2) Relay: SPST 5A at 250 VAC, Transistor: NPN Open collector 100 mA / 30 VDC residual voltage = 1.5 VDC max.
  • Inputs : Dry contact, PNP, or NPN.
  • Timing Functions : 14 pre-programmed timing functions.
  • Display : Two-line 6 digit negative transmissive LCD display.

Applications:

  • Industrial ovens
  • Batch counting in conveyor systems
  • Silk screening equipment

Additional Information:

  • Item Code: Series-LCT216
 

Electronic Fan Speed Control

Rs 4,500 / Piece

Condition New
Weight 1 lb 11 oz (.77 kg).
Model Number Model-FC-1000
Connection New
Temperature Range -40 to 131 Degree F (-40 to 55 Degree C).
Brand DWYER USA
Line Voltage Range 120-277 VAC, 60 Hz.
Input Signal Voltage 0-10 VDC.
Low Voltage Input 24 VAC, Class 2
Input Signal Impedance 10K ohms.
Locked Rotor Amp Rating 24.0.
Enclosure Rating NEMA 1.
Electronic Fan Speed Control

The Model FC-1000 Electronic Fan Speed Control provides precise speed modulation of small AC motors. Popular 0-10 VDC input works with most process controllers, eliminating the need for more expensive dampers, damper actuators and linkages while improving overall energy efficiency of the system. This inexpensive unit enables variable control ventilation fans, condenser fans and interfacing with VAV box controllers.

 

Features:

  • Compact design allows for use in most areas
  • Improves energy efficiency in systems

Specification:

  • Full Load Amp Rating : 9.8 @ 120 VAC, 9.3 @ 208 VAC, 8.0 @ 240 VAC, 6.9 @ 277 VAC.
  • Electrical Connections : Line voltage: 10-32 screw terminals; Signal and low voltage input: 1/4″ quick connects.
  • Transient Protection : 320V surge suppression. Exceeds IEEE C62.41 standards.
  • Housing Materials : Cold rolled steel.
  • Mounting : Vertical only; four holes provided for 10 screws.

 

Applications:

  • Monitoring fans and motors

Additional Information:

  • Item Code: Model-FC-1000

 

 

 

Ice Cube Relays

Rs 12 / Piece

Model No Series-784-4PDT
Model Number 784-4PDT
Weight 2.8 oz (80 g).
Brand DWYER USA
Condition New
Application HVAC motor controls
Operating and Load Voltage Range 24 to 120 VAC, 24 VDC
Switching Operation 4PDT
Electrical Rating 15 A 120 VAC 50/60Hz; 12 A 277 VAC 50/60 Hz or 28 VDC.
Storage Temperature -40 to 185 Degree F (-40 to 85 Degree C)
Operation Temperature -40 to 131 Degree F (-40 to 55 Degree C).
Power Consumption 1.5 VA; 1.5 W.
Cycle Life 200000 cycles (electrical); 10000000 cycles (mechanical).
Housing Plastic polycarbonate.

Ice Cube Relays

The Series 784 Electromechanical Ice Cube Relay is a full-featured 4PDT relay that can be used to handle loads up to 15 amps for AC or DC circuits. Utilizing the same trigger, this relay can be used in underground parking garage applications to signal audible and visual alarms for high levels of carbon monoxide, while opening the dampers and starting the exhaust fans. It features a flag status indicator and a LED status lamp to let the user know when the relay is activated. In order to differentiate between AC and DC actuated models, the push-to-test button is color-coded. For testing the operation, a removable lockdown lever holds the test button in place. The clear plastic housing gives a view of the contacts and there is a removable I.D. tag for labeling the circuit.

Features:

  • Clear plastic housing to easily view the contacts
  • Flag and LED status indicators for visual confirmation of relay state
  • Socket mounted for quick installation/replacement

Applications:

  • Refrigeration compressor systems
  • HVAC motor controls
  • Water/wastewater pump control

Additional Information:

  • Item Code: Series-784-4PDT
 

Low Cost Digital Timer

Rs 6,700 / Piece

Model Series-LCT316
Brand DWYER USA
Weight 5.6 oz (158.8 g).
Usage/Application Commercial cooking equipment
Display Type Digital
Applications Commercial dish washers and refrigeration equipment
Item Code Series-LCT316
Operating Temperature 32 to 158 Degree F (0 to 70 Degree C).
Control Output Ratings Relay, SPST, 16A at 250 VAC resistive.
Status Light LED shows time and operation.
Inputs Digital input for start and reset.
Supply Voltage 115 VAC, 230 VAC, 12 VAC/DC, 24 VAC/DC depending on model
Power Consumption 4VA

Low Cost Digital Timer

The Series LCT316 Low Cost Digital Timer provides accurate countdown timing for a variety of applications. The timer can be triggered remotely using the digital input terminals or locally via the set button. Time intervals can be set up to 999 minutes or seconds. The Series LCT316 has an internal buzzer to alert when the time interval has expired.

Features:

  • 1 second to 999 minute field set time interval
  • Audible alarm for status indication

Applications:

  • Commercial cooking equipment
  • Commercial dish washers and refrigeration equipment

 

Other Details:

Model Supply Power
LCT316-100 115 VAC
LCT316-200 230 VAC
LCT316-300 12 VAC/DC
LCT316-400 24 VAC/DC

 

Additional Information:

  • Item Code: Series-LCT316

Particulate Monitor

Rs 50,000 / Piece

Brand DWYER USA
Condition New
Model No Series-DPM
Usage/Application Baghouses
Weight 4.5 lbs (2.0 kg)
Inputs From PMS Sensor.
Power Requirement 115 VAC 50/60 Hz, 230 VAC 50/60 Hz, or 24 VDC.
Power Consumption 6 Watts Max.
Display LCD
Temperature -13 to 160 Degree F (-25 to 70 Degree C).

Particulate Monitor

The DPM Particulate Monitor and PMS Particulate Sensor combine to provide a basic baghouse and cartridge filter leak detector designed for general maintenance planning and process protection. It is easy to use and reliable. Leakage is gaged in real-time, on-the-spot, without prior baseline data and without signal tuning. Simply apply power and the general condition of the filter is quickly determined. An alarm point is set by simply moving an indicator up and down the gage with the convenient, lockable key pad. For more precise alarm setup the large display provides both a logarithmic analog bar graph and an absolute digital readout. The log scale enables the user to observe both the baseline bleed through and the high peaks that are caused by filter cleaning cycles and developing leaks. Observation of both baseline and peaks is essential to setting proper alarms. The digital readout in absolute units ensures correct interpretation of the readings and provides accurate historical comparisons.

 

The DPM Particulate Monitor is housed in a rugged cast aluminum enclosure. An LCD displays particulate levels in bar-graph and digital forms. A lockable membrane keypad is provided for setup and adjustment.

 

Features:

  • Rugged cast aluminum housing with lockable membrane keypad
  • Programmable alarm points
  • Large LCD to display readouts digitally


Specification:

  • Output Ratings : Alarm Relays: 2 Form A (SPST) rated 5A @ 240V res. (must provide an 8A [maximum] fuse in series with relay load); Analog: 4 to 20 mA (Option RC).
  • Accuracy : Standard: ±5% of range; Optional: ±1% of range.
  • Display Resolution : Standard: 5 pA; Optional: 0.5 pA.
  • Memory Backup : For set point storage only.
  • Enclosure : Cast aluminum, weatherproof, NEMA 4X.
  • Loop Power Supply (Isolated) : 17 VDC loop supply provided by DPM control unit for PMS sensor.

Applications:

  • Baghouses
  • Cartridge Filters
  • Bin Vents

Request
Callback

Additional Information:

  • Item Code: Series-DPM
 

Particulate Sensor

Rs 20,700 / Piece

Model Number Series-PMS
Ambient Temperature -40 to 392 Degree F (-40 to 200 Degree C)
Connection New
Condition New
Brand DWYER USA
Application/Usage Cartridge Filters
Usage/Application Baghouses
Wetted Materials 304SS and PTFE.
Electrical Connection Low noise coaxial.

Particulate Sensor

The PMS Particulate Sensor employs a field-proven combination of passive-induction and protected-probe technologies. As particles flow near and around the probe, minute currents are dynamically induced into the probe by flowing particulate. A DSP processes the signal into an absolute output that is reasonably linear to mass. Protective layers over the probe work in combination with induction-sensing to ensure reliable operation with all types of particulate including moist powders and highly conductive dusts. Maintenance is minimal and there is no need for an air purge. For durability, the sensors are passive and free of electronics. The PMS Particulate Sensor is designed to be used with the DPM Particle Monitor in order to be intrinsically safe.

Features:

  • Durable housing that is free of electronics
  • Minimal maintenance needed

Specification:

  • Service : Air and compatible gases, any type particulate.
  • Pressure Limits : Standard: Full vacuum to 10 psi (0.69 bar); Optional: 100 psi (6.89 bar).
  • Output Signal : pA.
  • Enclosure : Standard: Painted cast aluminum, weatherproof, NEMA 4X; Optional: Intrinsically Safe, CSA.
  • Weight : Varies depending on length of probe and type of mount.

Applications:

  • Baghouses
  • Cartridge Filters
  • Bin Vents

Additional Information:

  • Item Code: Series-PMS
 

Particulate Transmitter

Rs 22,000 / Piece

Application Filter leak or wear detection
Usage/Application Bin vent monitoring
Accuracy +/-5% of reading.
Model Number Series-PMT2
Output Signal 4 to 20 mA.
Enclosure Powder coated aluminum.
Brand DWYER USA
Condition New
Application/Usage Broken bag detection in dust collectors
Applications Emissions monitoring
Wetted Materials 316L SS, silicone, and PTFE.
Particulate Size 0.3 microns and higher.
Detection Range 5 to 5000 pA (6 selectable range options).
Pressure Limit 30 psi (2 bar).
Power Requirements 12 to 28 VDC.

Particulate Transmitter

The SERIES PMT2 Particulate Transmitter is designed to measure particulate emission levels from dust collector discharge. Using DC coupled electrostatic induction sensing technology, the transmitter monitors a pA current that is generated as particulate passes near the probe; a 4 to 20 mA signal will vary based on the particulate level. The PMT2 offers 6 sensitivity ranges allowing the user to choose the range that will best fit the application. The range and test selector switch can also be set to output a 4 mA or 20 mA signal to assist with set up or trouble shooting. Averaging time setting can be used to dampen the signal if desired.

Features:

  • Simple 2-wire installation for PLC and control panels
  • Non-stick PTFE coated probe to prevent false readings from moist and conductive dusts, condensate, and dust buildup
  • Remote zero calibration helps to decrease maintenance time


Specification:

  • Temperature Limits:Ambient: -40 to 145°F (-40 to 63°C); Process: -40 to 248°F (-40 to 120°C).
  • Electrical Connection : Two 1/2″ female NPT conduit openings.
  • Terminal Block : Removable (16 to 20 AWG wire).
  • Enclosure Rating : Type 4 (IP66).
  • Mounting Orientation : Any.
  • Averaging Time : 1 to 360 s (10 selectable options).
  • Weight: Varies with length of probe and type of mount.

Applications:

  • Emissions monitoring
  • Broken bag detection in dust collectors
  • Filter leak or wear detection
  • Bin vent monitoring

Additional Information:

  • Item Code: Series-PMT2
 

Process Indicator

Rs 5,500 / Piece

Usage/Application Display process values from various transmitters
Condition New
Model Series-LCI132
Display Type Digital
Humidity Range 95% 40 Degree C.
Brand DWYER USA
Temperature Coefficient 100 ppm/ Degree C.
Warm Up 5 minutes
Operating Temperature -10 to 60 Degree C
Storage Temperature -25 to +85 Degree C
Panel Sealing NEMA 4X (IP66).

Process Indicator

THE SERIES LCI132 PROCESS INDICATORS offer flexibility and value in a low cost, compact 1/32 DIN package. The shallow depth of these full size panel meters allows installation in panels only 2.76″ (70 mm) deep with room to spare.

Features:

  • Fits in 1/32 DIN panel cutouts
  • IP65 (NEMA 4X) front housing
  • Fully programmable
  • Various voltage and current inputs fits most processes

Specification:
Model – LCI132-0X

  • Range : Input Volts (DC): ±200 V, ±20 V, ±10 V; Input Amperes: ±100 mV, ±20 mA;
  • Resolution : Input Volts (DC): 0.1 V, 0.01 V, 1 mV; Input Amperes: 0.1 mV, 0.01 mA; Input Impedance: Volts: 1 M Ω, mV: 100 M Ω, mA: 12.1 Ω.

Model – LCI132-1X

  • Range AC : Input Volts: 600.0, 100.0; Input Amperes: 5.000, 1.000;
  • Range DC : Input Volts: -199.9, ±600.0, ±100.0; Input Amperes: -1.999, +5.000, ±1.000;
  • Resolution : Input Volts: 0.1 V; Input Amperes: 1 mA Input Impedance: Volts: 3 M Ω (106), Amps: 12 m Ω (10-3).
  • Accuracy at 23ºC ±5ºC : 100/600 VDC 1/5 A DC; 600V/5A AC: ±(0.2% reading + 3 digits). 100 V / 1A AC: ±(0.4% reading + 4 digits).

Power Supply and Fuses (DIN 41661) (Not supplied):

  • LCI132-X0 : 85–265 VAC 50/60 Hz and 100-300 VDC: Fuse: 0.1A/ 250V.
  • LCI132-X1 : 21-53 VAC 50/60Hz and 10.5-70 VDC: Fuse 0.5A/ 250V.

Display:

  • LCI132-X0 : 85–265 VAC 50/60 Hz and 100-300 VDC: Fuse: 0.1A/ 250V.
  • LCI132-X1 : 21-53 VAC 50/60Hz and 10.5-70 VDC: Fuse 0.5A/ 250V.

Applications:

  • Display process values from various transmitters

 

Other Details:

Model Input Supply Voltage
LCI132-00 ±100 VDC; ±20 VDC; ±10 VDC; ±200 VDC; ±20 mA DC 120/240 VAC
LCI132-01 ±100 VDC; ±20 VDC; ±10 VDC; ±200 VDC; ±20 mA DC 24/48 VAC
LCI132-10 ±100 VAC; 600 VAC; 5 A (DC) 1A (AC); -199.9 to +600 VDC; ±100 VDC -1.999 to 5 A (DC) ±1 A (DC); 120/240 VAC
LCI132-11 ±100 VAC; 600 VAC; 5 A (DC) 1 A (AC); -199.9 to +600 VDC; ±100 VDC -1.999 to 5 A (DC) ±1 A (DC); 24/48 VAC

Additional Information:

  • Item Code: Series-LCI132

 

Process and Temperature Alarm Switch Module

 

Rs 6,500 / Piece

Operating Temperature 32 to 131 Degree F (0 to 55 Degree C).
Model No. Series-SC1
Storage Temperature -40 to 176 Degree F (-40 to 80 Degree C).
Brand DWYER USA
Usage/Application Industrial processing equipment
Application Stand alone CO monitoring in parking garage
Isolation 1500 V rms between outputs, input, and power.
Set Points Adjustable 0 to 100% of span.
Deadband Adjustable 0.25% to 100% of span.
Dimension 2.95″ H x 0.89″ W x 3.89″ D (75 x 22.5 x 98.5 mm).

Process and Temperature Alarm Switch Module

The Series SC1 Thermocouple Limit/Alarm Switch Modules are on-off or limit switches with selectable process signal. Input type, scale range, output action, and output type are all selectable by the user in the field. All selections are made through easily accessible switches without the need to open the product. Each unit has two form C (SPDT) relays which can operate independently, or be logically connected to operate as a DPDT output. A two color LED indicator indicates the status of each output relay.

These units mount easily on a standard 35 mm DIN rail. Low Voltage (SCLXXXX) units are also available.

 

Features:

  • Accepts current, voltage, thermocouple, or RTD inputs
  • Mounts on standard 35 mm DIN rail
  • Two color LED indicator to indicate the status of each output relay
  • Programmable input type, scale range, output action, and output type

 

Specification:

  • Power Supply : SC models: 85 to 265 VDC/VAC, 50 to 400 Hz; SCL models: 12 to 24 VDC/VAC, 50 to 400 Hz.
  • Drift  : ±0.02%/°C typical ±0.05%/°C maximum.
  • Excitation Current : (SC1490) Cu10Ω = 5 mA; Plt 100Ω, Ni 100Ω, Ni 120Ω = 500µA; Plt 500Ω, NiFe 1000Ω = 100 µA; Plt 1000Ω = 50 µA.
  • Lead Compensation Error : (SC1490) ˜ 0.02%/Ω.
  • Open Lead Protection : (SC1490) upscale only.
  • Input Impedance : SC1090: Voltage input = 1 MΩ, current input = 10Ω; SC1290: 3 MΩ.
  • Sensor Burnout Protection : Selectable.
  • Relay Output : Form C, SPDT, one per set point, 5A @ 250 VAC, resistive.
  • Latch Circuit Reset : Automatic at power up. Manual with reset switch on front of module.
  • Indicators : One dual color LED per set point. Red = relay on, green = relay off.
  • Wiring Terminals : Screw driven compression type.

Applications:

  • Stand alone CO monitoring in parking garage
  • Industrial processing equipment

Other Details:

Model Description Power Supply
SC1090 4 to 20 mA, 10 to 50 mA, 0 to 20 mA, 0 to 10 V, -10 to 10 mV 85 to 265 VDC/VAC
SC1290 Thermocouple type J, K, R, S, T, E 85 to 265 VDC/VAC
SC1490 RTD Pt1000 Ni100, Ni120, Cu10, Ni-Fe1000, Ni-Fe2000 85 to 265 VDC/VAC
SCL1090 4 to 20 mA, 10 to 50 mA, 0 to 20 mA, 0 to 10 V, -10 to 10 mV 12 to 24 VDC/VAC
SCL1290 Thermocouple type J, K, R, S, T, E 12 to 24 VDC/VAC
SCL1490 RTD Pt1000 Ni100, Ni120, Cu10, Ni-Fe1000, N-Fe2000 12 to 24 VDC/VAC

Additional Information:

  • Item Code: Series-SC1

Zener Barrier

Rs 1,700 / Piece

Weight 4.9 oz (140 g).
Power 20 to 35 VDC w.r.t. earth.
Model Number Series-MTL7706-7787
Brand DWYER USA
Connection New
Condition New
Storage Temperature -40 to 176 Degree F (-40 to 80 Degree C).
Usage/Application Electrically isolates pressure and level transmitters from unregulated circuits for intrinsically sa
Safe Area Output 4 to 20 mA.
LED Indicator Green Power Indication.
Operating Temperature -4 to 140 Degree F (-20 to 60 Degree C)
Humidity 5 to 95% RH.

Zener Barrier

The MTL7706/7787 is an intrinsically safe (IS) shunt-diode barrier that can be used to communicate with and provide isolations for certain Dwyer® transmitters approved for use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.

Features: 

  • Approved for use in hazardous areas

Specification:

  • Transmitter Voltage : 16.2 V @ 20 mA with 250Ω load (negative w.r.t. earth); 11.0 V @ 20 mA with 500Ω load (negative w.r.t. earth).
  • Accuracy : ±2 µA under all conditions.
  • Terminals : Accommodate up to 2.5 mm² stranded or single-core.
  • Safety Description : 28 µV, 300Ω, 93 mA.

Applications:

  • Electrically isolates pressure and level transmitters from unregulated circuits for intrinsically safe application

Request
Callback

Additional Information:

  • Item Code: Series-MTL7706-7787
 

Leave a Reply

Your email address will not be published. Required fields are marked *