Huba Switzerland Pressure Transmitter Wholesaler

Huba 511.915003841 Pressure Transmitter 0 – 4 bar

 
 
Minimum Order Quantity1 Number
Model Number511.915003841
BrandSwitzerland
Frequency Range0 – 4 Bar
Usage/ApplicationIndustrial Process Monitoring, Irrigation System Pressure
Output Voltage4-20mA
Product Weight200 g
Rated Supply Voltage8-33 VDC

Huba 511.915003841 Pressure Transmitter 0 – 4 bar These compact OEM Pressure Transmitters Type 511 Meet The Highest Specification for Mechanical Stress, EMC Compatibility, and Operational Reliability, Which Means That This Range is Particulary Suitable For All Demanding Industrial Applications. This Sensor Utilises a Ceramic Technology, Developed by Huba Control and for the Last 20 Years, in Millions of Applications, Used in Combination With Unique Integrated Electronic Design, Means That The Type 511 Series Has a High Degree of Accuracy For All Temperature Ranges. These Units Are Available In Small Or Production Quantities, With An Excellent Price To Performance Ratio.

Fixed Order Quantities On Request
  • Medium Liquids And Gases
  • Pressure Range -1 … 0 – 600 bar
  • Output 0 … 5 V, 1 … 6 V, 0 … 10 V, 4 … 20 mA
  • Accuracy < 0.5% fs
  • Electrical Connection Cable 1.5 m, swift connector, AMP JPT, M12x1, Connector DIN EN 175301-803-C
  • Pressure Connection Inside Thread Or Out Side Thread.
  • Compact And Rugged Construction For Highest Operational Reliability.
  • No Media Egress When Exceeding Rupture Pressure.
  • Negligible Temperature Influence On Accuracy.
  • Excellent EMC Capacity.
  • Saving Time By Quick Cable Mounting By The Customer With Swift Connector.
 

Huba 511.917003571 Pressure Transmitter 0 – 6 bar

 

 
Minimum Order Quantity1 Number
Model Number511.917003571
BrandSwitzerland
Frequency Range0 – 6 Bar
Usage/ApplicationIndustrial Process Monitoring, Irrigation System Pressure
Product Weight200 g
Rated Supply Voltage8-33 VDC
Output Type4-20 mA


Huba 511.917003571 Pressure Transmitter 0 – 6 bar These compact OEM Pressure Transmitters Type 511 Meet The Highest Specification for Mechanical Stress, EMC Compatibility, and Operational Reliability, Which Means That This Range is Particulary Suitable For All Demanding Industrial Applications. This Sensor Utilises a Ceramic Technology, Developed by Huba Control and for the Last 20 Years, in Millions of Applications, Used in Combination With Unique Integrated Electronic Design, Means That The Type 511 Series Has a High Degree of Accuracy For All Temperature Ranges. These Units Are Available In Small Or Production Quantities, With An Excellent Price To Performance Ratio.

Fixed Order Quantities On Request

  • Medium Liquids And Gases
  • Pressure Range -1 … 0 – 600 bar
  • Output 0 … 5 V, 1 … 6 V, 0 … 10 V, 4 … 20 mA
  • Accuracy < 0.5% fs
  • Electrical Connection Cable 1.5 m, swift connector, AMP JPT, M12x1, Connector DIN EN 175301-803-C
  • Pressure Connection Inside Thread Or Out Side Thread.
  • Compact And Rugged Construction For Highest Operational Reliability.
  • No Media Egress When Exceeding Rupture Pressure.
  • Negligible Temperature Influence On Accuracy.
  • Excellent EMC Capacity.
  • Saving Time By Quick Cable Mounting By The Customer With Swift Connector

Huba 511.930003842 Pressure Transmitter 0 – 10 bar

 
 
Minimum Order Quantity1 Number
Model Number511.930003842
BrandSwitzerland
Frequency Range0 – 10 Bar
Usage/ApplicationIndustrial Process Monitoring, Irrigation System Pressure
Product Weight200 g
Rated Supply Voltage8-33 VDC
Output Type4-20 mA

Huba 511.930003842 Pressure Transmitter 0 – 10 bar These compact OEM Pressure Transmitters Type 511 Meet The Highest Specification for Mechanical Stress, EMC Compatibility, and Operational Reliability, Which Means That This Range is Particulary Suitable For All Demanding Industrial Applications. This Sensor Utilises a Ceramic Technology, Developed by Huba Control and for the Last 20 Years, in Millions of Applications, Used in Combination With Unique Integrated Electronic Design, Means That The Type 511 Series Has a High Degree of Accuracy For All Temperature Ranges. These Units Are Available In Small Or Production Quantities, With An Excellent Price To Performance Ratio.

Fixed Order Quantities On Request
  • Medium Liquids And Gases
  • Pressure Range -1 … 0 – 600 bar
  • Output 0 … 5 V, 1 … 6 V, 0 … 10 V, 4 … 20 mA
  • Accuracy < 0.5% fs
  • Electrical Connection Cable 1.5 m, swift connector, AMP JPT, M12x1, Connector DIN EN 175301-803-C
  • Pressure Connection Inside Thread Or Out Side Thread.
  • Compact And Rugged Construction For Highest Operational Reliability.
  • No Media Egress When Exceeding Rupture Pressure.
  • Negligible Temperature Influence On Accuracy.
  • Excellent EMC Capacity.
  • Saving Time By Quick Cable Mounting By The Customer With Swift Connector.
 

Huba 511.930007041 Pressure Transmitter 0 – 10 Bar

 
 
Minimum Order Quantity1 Number
Model Number511.930007041
BrandSwitzerland
Frequency Range0 – 10 Bar
Usage/ApplicationIndustrial Process Monitoring, Irrigation System Pressure
Product Weight200 g
Rated Supply Voltage16-34 VDC
Output Type0-10 V


Huba 511.930007041 Pressure Transmitter 0 – 10 bar These compact OEM Pressure Transmitters Type 511 Meet The Highest Specification for Mechanical Stress, EMC Compatibility, and Operational Reliability, Which Means That This Range is Particulary Suitable For All Demanding Industrial Applications. This Sensor Utilises a Ceramic Technology, Developed by Huba Control and for the Last 20 Years, in Millions of Applications, Used in Combination With Unique Integrated Electronic Design, Means That The Type 511 Series Has a High Degree of Accuracy For All Temperature Ranges. These Units Are Available In Small Or Production Quantities, With An Excellent Price To Performance Ratio.

Fixed Order Quantities On Request

  • Medium Liquids And Gases
  • Pressure Range -1 … 0 – 600 bar
  • Output 0 … 5 V, 1 … 6 V, 0 … 10 V, 4 … 20 mA
  • Accuracy < 0.5% fs
  • Electrical Connection Cable 1.5 m, swift connector, AMP JPT, M12x1, Connector DIN EN 175301-803-C
  • Pressure Connection Inside Thread Or Out Side Thread.
  • Compact And Rugged Construction For Highest Operational Reliability.
  • No Media Egress When Exceeding Rupture Pressure.
  • Negligible Temperature Influence On Accuracy.
  • Excellent EMC Capacity.
  • Saving Time By Quick Cable Mounting By The Customer With Swift Connector.


Huba 511.932003842 Pressure Transmitter 0 – 25 bar

 
 
Minimum Order Quantity1 Number
Model Number511.932003842
BrandSwitzerland
Frequency Range0 – 25 Bar
Usage/ApplicationIndustrial Process Monitoring, Irrigation System Pressure
Product Weight200 g
Rated Supply Voltage8-33 VDC
Output Type4-20 mA

Huba 511.932003842 Pressure Transmitter 0 – 25 bar These compact OEM Pressure Transmitters Type 511 Meet The Highest Specification for Mechanical Stress, EMC Compatibility, and Operational Reliability, Which Means That This Range is Particulary Suitable For All Demanding Industrial Applications. This Sensor Utilises a Ceramic Technology, Developed by Huba Control and for the Last 20 Years, in Millions of Applications, Used in Combination With Unique Integrated Electronic Design, Means That The Type 511 Series Has a High Degree of Accuracy For All Temperature Ranges. These Units Are Available In Small Or Production Quantities, With An Excellent Price To Performance Ratio.

Fixed Order Quantities On RequestMedium Liquids And Gases:
  • Pressure Range -1 … 0 – 600 bar
  • Output 0 … 5 V, 1 … 6 V, 0 … 10 V, 4 … 20 mA
  • Accuracy < 0.5% fs
  • Electrical Connection Cable 1.5 m, swift connector, AMP JPT, M12x1, Connector DIN EN 175301-803-C
  • Pressure Connection Inside Thread Or Out Side Thread.
  • Compact And Rugged Construction For Highest Operational Reliability.
  • No Media Egress When Exceeding Rupture Pressure.
  • Negligible Temperature Influence On Accuracy.
  • Excellent EMC Capacity.
  • Saving Time By Quick Cable Mounting By The Customer With Swift Connector.
 

Huba 511.940003842 Pressure Transmitter 0 – 60 Bar

 
 
Minimum Order Quantity1 Number
Model Number511.940003842
BrandSwitzerland
Frequency Range0 – 60 Bar
Usage/ApplicationIndustrial Process Monitoring, Irrigation System Pressure
Product Weight200 g
Rated Supply Voltage8-33 VDC
Output Type4-20 mA

Huba 511.940003842 Pressure Transmitter 0 – 60 bar These compact OEM Pressure Transmitters Type 511 Meet The Highest Specification for Mechanical Stress, EMC Compatibility, and Operational Reliability, Which Means That This Range is Particulary Suitable For All Demanding Industrial Applications. This Sensor Utilises a Ceramic Technology, Developed by Huba Control and for the Last 20 Years, in Millions of Applications, Used in Combination With Unique Integrated Electronic Design, Means That The Type 511 Series Has a High Degree of Accuracy For All Temperature Ranges. These Units Are Available In Small Or Production Quantities, With An Excellent Price To Performance Ratio.

Fixed Order Quantities On Request:
  • Medium Liquids And Gases
  • Pressure Range -1 … 0 – 600 bar
  • Output 0 … 5 V, 1 … 6 V, 0 … 10 V, 4 … 20 mA
  • Accuracy < 0.5% fs
  • Electrical Connection Cable 1.5 m, swift connector, AMP JPT, M12x1, Connector DIN EN 175301-803-C
  • Pressure Connection Inside Thread Or Out Side Thread.
  • Compact And Rugged Construction For Highest Operational Reliability.
  • No Media Egress When Exceeding Rupture Pressure.
  • Negligible Temperature Influence On Accuracy.
  • Excellent EMC Capacity.
  • Saving Time By Quick Cable Mounting By The Customer With Swift Connector.
 

Huba 511.941003842 Pressure Transmitter 0 – 100 bar

 
 
Minimum Order Quantity1 Number
Model Number511.941003842
BrandSwitzerland
Frequency Range0 – 100 Bar
Accuracy< 0.5% fs
Usage/ApplicationIndustrial Process Monitoring, Irrigation System Pressure
Product Weight200 g
Rated Supply Voltage8-33 VDC
Output Type4-20 mA

Huba 511.941003842 Pressure Transmitter 0 – 100 bar These compact OEM Pressure Transmitters Type 511 Meet The Highest Specification for Mechanical Stress, EMC Compatibility, and Operational Reliability, Which Means That This Range is Particulary Suitable For All Demanding Industrial Applications. This Sensor Utilises a Ceramic Technology, Developed by Huba Control and for the Last 20 Years, in Millions of Applications, Used in Combination With Unique Integrated Electronic Design, Means That The Type 511 Series Has a High Degree of Accuracy For All Temperature Ranges. These Units Are Available In Small Or Production Quantities, With An Excellent Price To Performance Ratio.

Fixed Order Quantities On Request
  • Medium Liquids And Gases
  • Output 0 … 5 V, 1 … 6 V, 0 … 10 V, 4 … 20 mA
  • Electrical Connection Cable 1.5 m, swift connector, AMP JPT, M12x1, Connector DIN EN 175301-803-C
  • Pressure Connection Inside Thread Or Out Side Thread.
  • Compact And Rugged Construction For Highest Operational Reliability.
  • No Media Egress When Exceeding Rupture Pressure.
  • Negligible Temperature Influence On Accuracy.
  • Excellent EMC Capacity.
  • Saving Time By Quick Cable Mounting By The Customer With Swift Connector.
 

Series 1900 Compact Low Differential Pressure Switches Wholesaler

1900 Dwyer Series Compact Low Differential Pressure Switches

 
 
Minimum Order Quantity1 Number
Model Number1900
Frequency Range0.07 to 20″ w.c.
Weight1lb. 4.5 oz. (581 g)
BrandDwyer USA
Electrical Rating15 A @ 120-480 VAC (~), 60 Hz
Usage/ApplicationAir Conditioning Refrigeration Coil Icing Detection; Defrost Cycle Initiation
Agency ApprovalsCE,UL,CSA,FM
Pollution Degree2
Process Connections1/8″ female NPT
Repeatability+-3%


1900 Dwyer Series Compact Low Differential Pressure Switches For air and non-combustible compatible gases, Series 1900 switches have set points from 0.07 to 20″ w.c. (1.8 to 508 mm). Set point adjustment is easy with range screw located inside conduit enclosure and prevents tampering. UL, CE and CSA listed, and FM approved. Dwyer 1900 Series Offers

Features:

  • Oversized check valves for smooth controlled operation
  • Mash proof vent valve (no needle valve)
  • Patented non-oil based lubricants used on all moving parts
  • Dual O-rings on all pistons to ensure zero leakage


Applications:

  • Air conditioning refrigeration coil icing detection; defrost cycle initiation
  • Clogged filter detection
  • Variable air volume controller

1900-00 Dwyer Series Compact Low Differential Pressure Switch Range 0.07-0.15

 
 
Minimum Order Quantity1 Number
Model Number1900-00
BrandDwyer USA
Frequency Range0.07-0.15″ W.C
Usage/ApplicationVariable Air Volume Controller,Clogged Filter Detection
Product Weight1lb. 4.5 oz. (581 g)
Electrical Rating15 A @ 120-480 VAC (~),60 Hz
Agency ApprovalsCE,UL,CSA,FM
Pollution Degree2
Process Connections1/8″ female NPT
Repeatability+-3%

1900-00 Dwyer Series Compact Low Differential Pressure Switch Range 0.07-0.15″ Most Popular SERIES 1900 Combines Advanced Design and Precision Construction to make these switches able to perform many of the tasks of larger, costlier units. Designed for air conditioning service, they also serve many fluidics, refrigeration, oven and dryer applications. Series 1900 switches have set points from 0.07 to 20″ w.c. (1.8 to 508 mm). Set point adjustment is easy with range screw located inside conduit enclosure. Internal location helps prevent tampering.
  • Compact size and repeatability, provides a high-value switch for many industrial and OEM applications.
  • Range screw protected inside enclosure provides simplifies making adjustments but prevents tampering.
 

1900-0 Dwyer Series Compact Low Differential Pressure Switch Range 0.15-0.55

 
 
Minimum Order Quantity1 Number
Model Number1900-0
BrandDwyer USA
Frequency Range0.15-0.55″ W.C
Usage/ApplicationAir Conditioning Refrigeration Coil Icing Detection; Defrost Cycle Initiation
Power/Voltage120-277 VAC
Pollution Degree2
Weight1lb. 4.5 oz. (581 g)
Agency ApprovalsCE,UL,CSA,FM
Process Connections1/8″ female NPT
Repeatability+-3%
Altitude Limit6560 ft (2000 m) max
Humidity Limit80% RH (non-condensing)

1900-0 Dwyer Series Compact Low Differential Pressure Switch Range 0.15-0.55 The Dwyer 1910-0 Compact Low Differential Pressure Switch combines advanced design and precision construction to make these switches able to perform many of the tasks of larger, costlier units. Designed for air conditioning service, they also serve many fluidics, refrigeration, oven and dryer applications. For air and non-combustible compatible gases, 19100 switches have set points from 0.15 – 0.55″ w.c.. Set point adjustment is easy with range screw located inside conduit enclosure. Internal location helps prevent tampering. UL, CE and CSA listed, and FM approved.
  • Flame-proof ATEX enclosure protects the device in hazardous areas
  • Compact size and repeatability, provides a high-value switch for many industrial and OEM applications
  • Range screw protected inside switch enclosure prevents tampering
  • No power to operate DPDT switch means no additional wiring or conduit reduces material and installation labor costs
  • Easy access for modifying set point simplifies adjustment
  • Both control contacts activate at the same time eliminating system issues where lead switch activities preventing the lagging switch from sending a signal
 

1900-1 Dwyer Series Compact Low Differential Pressure Switch Range 0.40-1.6″ W.C

 
 
Minimum Order Quantity1 Number
BrandDwyer USA
Media TypeGas
IP Rating0.40-1.6″ W.C
Model Number1900-1
Power/Voltage120-277 VAC
Weight1lb. 4.5 oz. (581 g)
Repeatability+-3%

1900-1 Dwyer Series Compact Low Differential Pressure Switch Range 0.40-1.6″ W.C Most popular SERIES 1900 combines advanced design and precision construction to make these switches able to perform many of the tasks of larger, costlier units. Designed for air conditioning service, they also serve many fluidics, refrigeration, oven and dryer applications. Series 1900 switches have set points from 0.07 to 20″ w.c. (1.8 to 508 mm). Set point adjustment is easy with range screw located inside conduit enclosure. Internal location helps prevent tampering.

  • Compact size and repeatability, provides a high-value switch for many industrial and OEM applications.
  • Range screw protected inside enclosure provides simplifies making adjustments but prevents tampering.
 

1900-5 Dwyer Series Compact Low Differential Pressure Switch Range 1.40-5.5

 
 
Minimum Order Quantity1 Number
Model Number1900-5
BrandDwyer USA
Frequency Range1.40-5.5″ W.C
Usage/ApplicationAir Conditioning Refrigeration Coil Icing Detection; Defrost Cycle Initiation
Power/Voltage120-277 VAC
Product Weight1lb. 4.5 oz. (581 g)
Repeatability+-3%
Process Connections1/8″ female NPT
Pollution Degree2

1900-5 Dwyer Series Compact Low Differential Pressure Switch Range 1.40-5.5″ Most popular SERIES 1900 combines advanced design and precision construction to make these switches able to perform many of the tasks of larger, costlier units. Designed for air conditioning service, they also serve many fluidics, refrigeration, oven and dryer applications. Series 1900 switches have set points from 0.07 to 20″ w.c. (1.8 to 508 mm). Set point adjustment is easy with range screw located inside conduit enclosure. Internal location helps prevent tampering.
  • Compact size and repeatability, provides a high-value switch for many industrial and OEM applications.
  • Range screw protected inside enclosure provides simplifies making adjustments but prevents tampering.
 

1900-10 Dwyer Series Compact Low Differential Pressure Switch Range 3.0-11.75

 
 
Minimum Order Quantity1 Number
Model Number1900-10
BrandDwyer USA
Frequency Range3.0-11.75″ W.C
Usage/ApplicationAir Conditioning Refrigeration Coil Icing Detection; Defrost Cycle Initiation
Product Weight1lb. 4.5 oz. (581 g)
Agency ApprovalsCE,UL,CSA,FM
Pollution Degree2
Process Connections1/8″ female NPT

1900-10 Dwyer Series Compact Low Differential Pressure Switch Range 3.0-11.75 Most popular Series 1900 combines advanced design and precision construction to make these switches able to perform many of the tasks of larger, costlier units. Designed for air conditioning service, they also serve many fluidics, refrigeration, oven and dryer applications. Series 1900 switches have set points from 0.07 to 20″ w.c. (1.8 to 508 mm). Set point adjustment is easy with range screw located inside conduit enclosure. Internal location helps prevent tampering.
  • Compact size and repeatability, provides a high-value switch for many industrial and OEM applications.
  • Range screw protected inside enclosure provides simplifies making adjustments but prevents tampering.
 

1920-10 Dwyer Series Compact Low Differential Pressure Switch Range 4.0-20.0

 
 
Minimum Order Quantity1 Number
Model Number1920-10
BrandDwyer USA
Frequency Range4.0-20.0″ W.C
Power120-277 VAC
Usage/ApplicationAir Conditioning Refrigeration Coil Icing Detection; Defrost Cycle Initiation
Product Weight1lb. 4.5 oz. (581 g)
Process Connections1/8″ female NPT
Repeatability+-3%
Agency ApprovalsCE,UL,CSA,FM

1920-10 Dwyer Series Compact Low Differential Pressure Switch Range 4.0-20.0 Most popular SERIES 1900 combines advanced design and precision construction to make these switches able to perform many of the tasks of larger, costlier units. Designed for air conditioning service, they also serve many fluidics, refrigeration, oven and dryer applications. Series 1900 switches have set points from 0.07 to 20″ w.c. (1.8 to 508 mm). Set point adjustment is easy with range screw located inside conduit enclosure. Internal location helps prevent tampering.
  • Compact size and repeatability, provides a high-value switch for many industrial and OEM applications.
  • Range screw protected inside enclosure provides simplifies making adjustments but prevents tampering.
 

1910-0 Dwyer Series Compact Low Differential Pressure Switch Range 0.15-0.55

 
 
Minimum Order Quantity1 Number
Model Number1910-0
BrandDwyer USA
Frequency Range0.15-0.55″ W.C
Power120-277 VAC
Usage/ApplicationAir Conditioning Refrigeration Coil Icing Detection; Defrost Cycle Initiation
Weight1lb. 4.5 oz. (581 g)
Agency ApprovalsCE,UL,CSA,FM
Pollution Degree2
Process Connections1/8″ female NPT
Repeatability+-3%

1910-0 Dwyer Series Compact Low Differential Pressure Switch Range 0.15-0.55 The Dwyer 1910-0 Compact Low Differential Pressure Switch combines advanced design and precision construction to make these switches able to perform many of the tasks of larger, costlier units. Designed for air conditioning service, they also serve many fluidics, refrigeration, oven and dryer applications. For air and non-combustible compatible gases, 19100 switches have set points from 0.15 – 0.55″ w.c.. Set point adjustment is easy with range screw located inside conduit enclosure. Internal location helps prevent tampering. UL, CE and CSA listed, and FM approved.
  • Flame-proof ATEX enclosure protects the device in hazardous areas
  • Compact size and repeatability, provides a high-value switch for many industrial and OEM applications
  • Range screw protected inside switch enclosure prevents tampering
  • No power to operate DPDT switch means no additional wiring or conduit reduces material and installation labor costs
  • Easy access for modifying set point simplifies adjustment
  • Both control contacts activate at the same time eliminating system issues where lead switch activities preventing the lagging switch from sending a signal
 

Static Pressure Tips & Accessories Dwyer Instruments

Dps Duct Kit

 
 
Country of OriginMade in India
ColorGRAY
Part NumberDPS Differential Air Pressure KIt
Weight56 G
MaterialPlastic/PVC
Special FeatureUnbreakable

DPS Duct Kit

Dwyer Differential pressure Transmitter For Air (DPTA) Accessories.


Duct Kit, Including 2M Silicone Hose And 2 Joining Pipes DPSJ With Screws.

 

Static Pressure Tip

 
 
Minimum Order Quantity100 Unit
Moulded Parts TypeStatic Pressure Tip
ColorWhite
MaterialPlastic
BrandENVIRO TECH INDUSTRIAL PRODUCTS
Packaging Type100 NOS
TypeStatic Pressure Tip
Usage/ApplicationDifferential Pressure Switch
Weight56 G
Country of OriginMade in India

Static Pressure Tip

These Sensors Are For Use With Manometers, Magnehelic® Gages, Differential Pressure Switches and Other Controllers to Pick Up Or Sense Static Pressure Drop Across Air Filters And Cooling Coils, Blower Input And Discharge Pressures, etc.

 

Grey Static Pressure Tip

 
 
MaterialABS
Country of OriginMade in India
ApplicationChemical,Laboratory,Industrial
Special FeatureUnbreakable
Usage/ApplicationDifferential Pressure Switch
Weight56 G

Grey Static Pressure Tip

Our Company Has Created a Niche in The Field Of Offering Static Pressure Tip.
 

Dwyer Plastic Static Pressure Tip

 
 
Moulded Parts TypeA-480
ColorWhite
MaterialPlastic
BrandDWYER
Packaging Type100
Usage/ApplicationMinihelic II Differential Pressure Gages, Magnesense Differential Pressure Transmitters, DigiMag Dig
Weight0.800 ounces
Country of OriginMade in India

Dwyer Plastic Static Pressure Tip

  • For Use With Dwyer Minihelic II Differential Pressure Gages, Magnesense Differential Pressure Transmitters, DigiMag Digital Differential Pressure and Flow Gages, ADPS/EDPS Differential Pressure Switches, and an array of other Dwyer products.
Specifications For This Item

Brand NameDwyer
Item Weight0.800 ounces
Number of Items1
Part NumberA-480
 

Plastic Static Pressure Tip

 
 
MaterialPlastic
Country of OriginMade in India
Moulded Parts TypeStatic Pressure Tip
ColorGray
Weight56 G
Usage/ApplicationDifferential Pressure Switch

Plastic Static Pressure Tip

These Sensors Are For Use With Manometers, Magnehelic Gages, Differential Pressure Switches and Other Controllers to Pick Up Or Sense Static Pressure Drop Across Air Filters And Cooling Coils, Blower Input And Discharge Pressures, etc.
 

ABS Static Pressure Tip

 
 
MaterialABS
Usage/ApplicationDifferential Pressure Switch
Country of OriginMade in India
ApplicationIndustrial
Item Weight0.800 ounces
MACKENVIRO TECH

Abs Static Pressure Tip
These Sensors Are For Use With Manometers, Magnehelic Gages, Differential Pressure Switches and Other Controllers to Pick Up Or Sense Static Pressure Drop Across Air Filters And Cooling Coils, Blower Input And Discharge Pressures, etc.

A-480 DWYER Plastic Static Pressure Tip

 
 
BrandDwyer
Wetted PartsPlastic
ColorWhite
ApplicationIndustrial, Laboratory
ModelA – 480

DPS Differential Air Pressure Kit

 
 
Minimum Order Quantity100 Piece
ColorGRAY
Packaging Type100
Part NumberDPS Differential Air Pressure KIt
Quantity Per Pack100
WarrantyYAS
Weight56 G
Usage/ApplicationDifferential Pressure Switch
I Deal InNew Only
MaterialPlastic
BrandENVIRO TECH INDUSTRIAL PRODUCTS
Country of OriginMade in India

DPS Differential Air Pressure KIt

Dwyer Differential pressure Transmitter For Air (DPTA) Accessories.


Duct Kit, Including 2M Silicone Hose And 2 Joining Pipes DPSJ With Screws.

 

Duct Fixing Kit

 
 
Minimum Order Quantity100 Unit
MaterialPlastic
Usage/ApplicationDifferential Pressure Switch
BrandENVIRO TECH INDUSTRIAL PRODUCTS
DesignStandard
Packaging Type1
ColorGRAY
Country of OriginMade in India

Duct Fixing Kit

Duct Fixing Kit ETIP 200 • ETIP 200 Includes 2 Plastic Tubes With Integrated Mounting Plate, 2 Metres PVC Hose And 4 Screws.

Duct Connection Set

 
 
Minimum Order Quantity500 Unit
BrandENVIRO TECH INDUSTRIAL PRODUCTS
Usage/ApplicationDifferential Pressure Switch
Model Name/NumberENVIRO TECH INDUSTRIAL PRODUCTS
MaterialPlastic
Weight56 G
Warranty1 YERS
Product TypeDuct Connection Set
Place Of OriginDELHI

Duct Connection Set

Duct Connection Set Comprising Two Plastic Pitot Tubes, Fixing Screws And 2 Metres of PVC Tubing, Suitable For 930.. & PTH-3202

Weight – 56 g

 

Series 1620 Single and Dual Pressure Switch Wholesaler

Dwyer 1620 Series Single and Dual Pressure Switches

 
 
Minimum Order Quantity1 Number
Media TypeGas, Air
Pressure Range.15-1.5″ w.c
Model Number1620
BrandDwyer USA
Usage/ApplicationAir And Non-combustible, Compatible Gases
Temperature Limits-30 to 130 deg F ( -34.4 to 54.4 deg C)
Pressure LimitsMax. 50 in. w.c. (12.44 kPa) continuous, 2 psig (13.79 kPa) surge
Repeatability+-1%
Process Connections1/8″ female NPT

Dwyer 1620 Series Single and Dual Pressure Switches High Reliability, Repetitive Accuracy within ±1% On the Series 1620 Single and Dual Pressure Switch, our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model 1626 and 1627 differential pressure switches are identical in design and construction except that Model 1626 has a single electric switch and Model 1627 has dual electric switches. Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Both units have diaphragm sealed motion take outs providing maximum protection against leakage.

Caution:

  • For Use Only With Air Or Compatible Gases.

 

Product Applications:
  • Damper positioning
  • Duct air control


Features:

  • Up to 3900 readings can be saved
  • Entire memory can be read out in only 10 seconds
  • Watertight housing (IP65)
  • ComSoft 3 Basic Windows-compatible software facilitates graphs and tables, prints data, smoothes measurement curves, targeted value observation using crosshair function as well as logger programming and setting of limit values
  • Data transfer via serial interface
 

Dwyer 1627-1 Series 1620 Single and Dual Pressure Switch Range – .15-1.5″ w.c.

 
 
Minimum Order Quantity1 Number
BrandDwyer USA
Media TypeGas
Electrical ConnectionScrew Terminals
Model Number1627-1 Series1620
Pressure Range.15-1.5″ W.C.
Weight3 lb 11.8 oz
Electrical Rating15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
Usage/ApplicationDamper Positioning
Temperature Limits-30 to 130 deg F
Repeatability+-1%
Agency ApprovalsCE

Dwyer 1627-1 Series 1620 Single and Dual Pressure Switch Range – .15-1.5″ w.c. Single and dual pressure switch, range .15-1.5″ w.c., .10 min. deadband, .20 max. deadband, 0.5 adj. diff. between set points. 
Series 1620 Dual Pressure Switch, Range .15-1.5″ w.c., .10 min. Deadband, .20 max. Deadband, 0.5 Adj. Diff. Between Set Points High Reliability, Repetitive Accuracy within ±1% Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has dual electric switches.Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Unit have diaphragm sealed motion take outs providing maximum protection against leakage.

Caution:

  • For Use Only With Air Or Compatible Gases.

 

Dwyer 1627-10 Series 1620 Single and Dual Pressure Switch Range 2.0-11″ w.c

 
 
Minimum Order Quantity1 Number
BrandDwyer USA
Media TypeGas
Electrical Connection3 screw type, common, normally open and normally closed
Model Number1627-10 Series 1620
Pressure Range2.0-11″ W.C
Weight3 lb 11.8 oz
Electrical Rating15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
Usage/ApplicationDuct Air Control
Temperature Limits-30 to 130 deg F
Pressure LimitsMax. 50 in. w.c. continuous, 2 psig surge
Switch TypeTwo single-pole double throw (SPDT)
Repeatability+-1%
Process Connections1/8″ female NPT
Mounting OrientationDiaphragm in vertical position
Set Point AdjustmentScrew adjustment
Agency ApprovalsCE

Dwyer 1627-10 Series 1620 Single and Dual Pressure Switch Range 2.0-11″ w.c Single and dual pressure switch, range 2.0-11″ w.c., .25 min. deadband, .65 max. deadband, 2.3 adj. diff. between set points.
High Reliability, Repetitive Accuracy within ±1% Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has dual electric switches.Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Unit have diaphragm sealed motion take outs providing maximum protection against leakage.

Caution:
  • For Use Only With Air Or Compatible Gases.
 

Dwyer 1627-20 Series 1620 Single and Dual Pressure Switch Range 8.0-24″ w.c

 
 
Minimum Order Quantity1 Number
BrandDwyer USA
Media TypeGas
Electrical ConnectionScrew Terminals
Model Number1627-20 Series1620
Pressure Range8.0-24″ W.C
Weight3 lb 11.8 oz
Electrical Rating15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
Usage/ApplicationDamper Positioning
Temperature Limits-30 to 130 deg F
Pressure LimitsMax. 50 in. w.c. continuous, 2 psig surge
Switch TypeTwo single-pole double throw (SPDT)
Repeatability+-1%
Electrical Connections3 screw type, common, normally open and normally closed
Process Connections1/8″ female NPT
Mounting OrientationDiaphragm in vertical position
Set Point AdjustmentScrew adjustment
Agency ApprovalsCE

Dwyer 1627-20 Series 1620 Single and Dual Pressure Switch Range 8.0-24″ w.c
Single and dual pressure switch, range 8.0-24″ w.c., .50 min. deadband, 1.20 max. deadband, 5.0 adj. diff. between set points. Series 1620 Single Electric Switch, Range 8.0-24″ w.c., .50 min. Deadband, 1.20 max. Deadband High Reliability, Repetitive Accuracy within ±1% Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has dual electric switches.Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Unit have diaphragm sealed motion take outs providing maximum protection against leakage.

Caution:
  • For Use Only With Air Or Compatible Gases.
 

Dwyer 1627-05 Series 16220 Single and Dual Pressure Switch Range .5-6.0

 
 
Minimum Order Quantity1 Number
BrandDwyer USA
Media TypeGas
Electrical ConnectionScrew Terminals
Model Number1627-05 Series 1620
Pressure Range.5-6.0″ W.C
Weight3 Ib,9.8 oz 1.64 kg
Usage/ApplicationDuct Air Control
Temperature Limits-30 to 130 deg F
Process Connections1/8″ female NPT
Agency ApprovalsCE

Dwyer 1627-05 Series 16220 Single and Dual Pressure Switch Range .5-6.0 Single and dual pressure switch, range .5-6.0″ w.c., .15 min. deadband, .35 max. deadband, 1.2 adj. diff. between set points. Series 1620 Single Electric Switch, Range .5-6.0″ w.c., .15 min. Deadband, .35 max. Deadband High Reliability, Repetitive Accuracy within ±1% Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has dual electric switches.Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Unit have diaphragm sealed motion take outs providing maximum protection against leakage.
 

Dwyer 1626-1 Series 1620 Single and Dual Pressure Switch Range – .15-1.5″ w.c.

 
 
Minimum Order Quantity1 Number
BrandDwyer USA
Media TypeGas
Electrical ConnectionScrew Terminals
Model Number1626-1
ApplicationDamper Positioning
Weight1.64 kg
Electrical Rating15 A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC, 60 Hz
Temperature Limits-30 to 130 deg F ( -34.4 to 54.4 deg C)
Pressure LimitsMax. 50 in. w.c. (12.44 kPa) continuous, 2 psig (13.79 kPa) surge
Repeatability+-1%
Process Connections1/8″ female NPT

Dwyer 1626-1 Series 1620 Single and Dual Pressure Switch Range – .15-1.5″ w.c. Single and dual pressure switch, range .15-1.5″ w.c., .10 min. deadband, .20 max. deadband, 0.5 adj. diff. between set points. The Dwyer 1626-1 Single and Dual Pressure Switch has a range of .15-1.5″ w.c., 10 min. deadband, 20 max. deadband, and 0.5 adj. diff. between set points. Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model 1626 and 1627 differential pressure switches are identical in design and construction except that Model 1626 has a single electric switch and Model 1627 has dual electric switches. Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Both units have diaphragm sealed motion take outs providing maximum protection against leakage.

Caution:

  • For Use Only With Air Or Compatible Gases.

Product Applications:

  • Damper positioning
  • Duct air control


Features:

  • Up to 3900 readings can be saved
  • Entire memory can be read out in only 10 seconds
  • Watertight housing (IP65)
  • ComSoft 3 Basic Windows-compatible software facilitates graphs and tables, prints data, smoothes measurement curves, targeted value observation using crosshair function as well as logger programming and setting of limit values
  • Data transfer via serial interface
 

Dwyer 1626-10 Series 1620 Single and Dual Pressure Switch Range 2.0-11″ w.c

 
 
Minimum Order Quantity1 Number
BrandDwyer USA
Media TypeGas
Electrical ConnectionScrew Terminals
Model Number1626-10
ApplicationDamper Positioning
Weight3 lb 9.8 oz
Electrical Rating15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
Temperature Limits-30 to 130 deg F
Repeatability+-1%
Process Connections1/8″ female NPT

 

Dwyer 1626-10 Series 1620 Single and Dual Pressure Switch Range 2.0-11″ w.c Single and dual pressure switch, range 2.0-11″ w.c., .25 min. deadband, .65 max. deadband, 2.3 adj. diff. between set points. Series 1620 Single Electric Switch, Range 2.0-11″ w.c., .25 min. Deadband, .65 max. Deadband High Reliability, Repetitive Accuracy within ±1% Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has a single electric switch.

Caution:

  • For Use Only With Air Or Compatible Gases.

Dwyer 1626-20 Series 1620 Single and Dual Pressure Switch Range 8.0-24″ w.c

 
 
Minimum Order Quantity1 Number
BrandDwyer USA
Media TypeGas
Electrical ConnectionScrew Terminals
Model Number1626-20
ApplicationDuct Air Control
Weight3 lb 9.8 oz

Dwyer 1626-20 Series 1620 Single and Dual Pressure Switch Range 8.0-24″ w.c Single and dual pressure switch, range 8.0-24″ w.c., .50 min. deadband, 1.20 max. deadband, 5.0 adj. diff. between set points. Series 1620 Single Electric Switch, Range 8.0-24″ w.c., .50 min. Deadband, 1.20 max. Deadband High Reliability, Repetitive Accuracy within ±1% Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has a single electric switch.

Caution:

  • For Use Only With Air Or Compatible Gases.
 

Dwyer 1626-05 Series 1620 Single and Dual Pressure Switch Range .5-6.0″ w.c

 
 
Minimum Order Quantity1 Number
BrandDwyer USA
Media TypeGas
Electrical ConnectionScrew Terminals
Model Number1626-05
ApplicationDamper Positioning
Weight3 Ib, 9.8 oz 1.64 kg
Electrical Rating15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
Temperature Limits-30 to 130 deg F
Repeatability+-1%
Agency ApprovalsCE

Dwyer 1626-05 Series 1620 Single and Dual Pressure Switch Range .5-6.0″ w.c Single and dual pressure switch, range .5-6.0″ w.c., .15 min. deadband, .35 max. deadband, 1.2 adj. diff. between set points. Series 1620 Single Electric Switch, Range .5-6.0″ w.c., .15 min. Deadband, .35 max. Deadband High Reliability, Repetitive Accuracy within ±1% Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has a single electric switch.

Caution:

  • For Use Only With Air Or Compatible Gases.
 

Series RHP Humidity Temperature Transmitter Wholesaler

RHP-2D10 DWYER Humidity Temperature Transmitter

 
 
Minimum Order Quantity12 Number
Model Name/NumberRHP-2D10
BrandDwyer USA
Voltage10~35 VDC
Accuracy2%
Usage/ApplicationIndustrial
Product Weight8.24 oz Gross Weight:1 lb
Protection TypeRHP-2D10 DWYER Humidity Temperature Transmitter
Part TypeRHP-2D10 DWYER Humidity Temperature Transmitter
SizeH x W x D:4 in x 4.4 in x 11.75 in
ItemRHP-2D10 DWYER Humidity Temperature Transmitter
Precautions For UseAir Economizers,Outdoor Temperature and Relative Humidity Reference,Pool Room Humidity Monitoring
Sensor Output4~20 mA
Humidity0 to 100% RH
Packaging Type1 NOS
Country of OriginMade in India


RHP-2D10 DWYER Humidity Temperature Transmitter

Overview

Dwyer Instruments

Humidity Sensors, RHP Series

  • Item# RHP-2D10 – Duct Mount Humid- Ity Transmitter Wtih 2% Sensor And 4-20 Ma Output


RHP Series Information

The Series RHP Temperature and Humidity Transmitter Combine the Voltage or Current Humidity Transmitter output with a passive Temperature Thermistor or RTD output. Featuring Polymer Capacitance Humidity Sensors, Models are available in 2%, 3% or 5% accuracies. Duct mounted transmitters are available with an optional two-line alpha numeric LCD Display.

Product Applications

  • Air Economizers
  • Outdoor Temperature and Relative Humidity Reference
  • Pool Room Humidity Monitoring


Specifications

  • Item Number:  RHP-2D10
  • Brand:Dwyer Instruments
  • Item Category:HVAC Sensors
  • Subcategory:Humidity Sensors
  • Series:RHP
  • Application:Duct
  • Input:10~35 VDC
  • Output:4~20 mA
  • Display:None
  • Humidity Range:0 to 100% RH
  • Temperature Sensor:No
  • Approvals:CE
  • Size:H x W x D:4 in x 4.4 in x 11.75 in
  • Net Weight:8.24 oz
  • Gross Weight:1 lb

RHP-2D1B DWYER Humidity Temperature Transmitter

 
 
Minimum Order Quantity12 Number
Model Name/NumberRHP-2D1B
BrandDWYER USA
Voltage4-20 mA
Accuracy2%
Usage/ApplicationIndustrial
Warranty1 YERS
ColorWHITE
ItemRHP-2D1B DWYER Humidity Temperature Transmitter

RHP-2D1B DWYER Humidity Temperature Transmitter

RHP-2D1B | Dwyer Instruments | Humidity

Relative Humidity, Passive Temperature Sensor Transmitter, 2%, Duct Mount with Plastic Hydrophobic Filter, 4-20 mA RH Output, 10K @ 25°C Thermistor Type II, No Options

  • Manufacturer:Dwyer Instruments
  • MPN:RHP-2D1B
  • SKU:RHP-2D1B

FAMILY DESCRIPTION 

  • The Series RHP Temperature and Humidity Transmitter Combine The Voltage or Current Humidity Transmitter Output With a Passive Temperature Thermistor or RTD Output.The Polymer Capacitance Humidity Sensor is Not Affected By Condensation,Fog, High Humidity,or Contaminants.The Humidity Sensors Are Available With 2% or 3% accuracies.Duct Mounted Transmitters Are Available With an Optional Two-Line Alpha Numeric LCD Display.Application Note: For Duct Mount Installations,The Sintered Filter Option Should Be Ordered For Applications Where The Humidity Transmitter Is Mounted In The Supply Air Duct After The Fan And Cooling Coils.

  • ENVIRO TECH Description – 2% DUCT RH/TEMP XMITER 4-20MA 10K II

  • Manufacturer – Dwyer Instruments

PRODUCT APPLICATIONS

  • Air Economizers
  • Outdoor Temperature and Relative Humidity Reference
  • Pool Room Humidity Monitoring

PRODUCT HIGHLIGHTS

  • Duct Mount
  • 2% RH/Temperature Transmitter
  • 4-20 mA RH Output
  • 10K at 25 C Thermistor Temperature Output

PRODUCT FAMILY FEATURES

  • Robust Capacitance Humidity Sensor
  • Models With LCD Display
  • Interchangeable Filter And Replaceable Sensor Options
 

RHP-3D11 DWYER Humidity Temperature Transmitter

 
 
Minimum Order Quantity12 No
Model Name/NumberRHP-3D11
BrandDWYER USA
Voltage0-5/10V
Accuracy+-3%
Usage/ApplicationIndustrial
Warranty1 YEAR
Product WeightDuct mount: .616 lb (.3 kg); OSA: 1 lb (.45 kg).
Rated Supply Voltage0-5/10V
Response Time15 seconds.

RHP-3D11 DWYER Humidity Temperature Transmitter

The Series RHP Temperature and Humidity Transmitter combine the Voltage or current Humidity Transmitter output with a passive temperature thermistor or RTD output. The polymer capacitance humidity sensor is not affected by condensation, fog, high humidity, or contaminants. The humidity sensors are available with 2% or 3% accuracies. Duct mounted transmitters are available with an optional two-line alpha numeric LCD display. Application Note: For duct mount installations, the sintered filter option should be ordered for applications where the Humidity Transmitter is mounted in the supply air duct after the fan and cooling coils.
Availability: Item ships in about Ships in 4-6 weeks
Product Highlights

  • Duct mount
  • 3% RH/temperature transmitter
  • 4-20 mA RH output
  • 4-20 mA temperature output
OTHER CONFIGURATIONS AVAILABLE
PRODUCT SPECIFICATIONS
  • Relative Humidity Range: 0 to 100% RH.
  • Temperature Range: -40 to 140°F (-40 to 60°C).
  • Accuracy, RH: RHP-2XXX ±2% 10-90% RH @ 25°C; RHP-3XXX ±3% 20-80% RH @ 25°C; RHP-5XXX ±5% 20-80% RH @ 25°C.
  • Accuracy, Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F).
  • Accuracy, RTD Temp Sensor: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F).
  • Hysteresis: ±1%.
  • Repeatability: ±0.1% typical.
  • Temperature Limits: -40 to 140°F (-40 to 60°C).
  • Storage Temperature: -40 to 176°F (-40 to 80°C).
  • Compensated Temperature Range: -4 to 140°F (-20 to 60°C).
  • 4-20 mA Loop Powered Models: Power Requirements: 10-35 VDC. Output Signal: 4-20 mA.
  • 0-5/10V Output Models: Power Requirements: 15-35 VDC or 15-29 VAC. Output Signal: 0-10V @ 5 mA max.
  • Response Time: 15 seconds.
  • Electrical Connections: Removable screw terminal block.
  • Conduit Connection: Duct Mount: 1/2″ NPS; OSA: 1/2″ (22.3 mm).
  • Drift: <1% RH/year.
  • RH Sensor: Capacitance polymer.
  • Temperature Sensor:
Types 1, 2, 3: Solid state band gap;
Curves A,B,C; Thermistor;
Curves D,E; Platinum RTD DIN 385. (See R-T Lookup Table).
  • Enclosure: Duct Mount: PBT; OSA: Polycarbonate.
  • Enclosure Rating: NEMA 4X (IP65) for OSA mount only.
  • Display: Duct Mount only, Optional 2-line alpha numeric, 8 characters/line.
  • Display Resolution: RH: 0.1%; 0.1°F (0.1°C).
 

RHP-3S22 DWYER Humidity Temperature Transmitter

 
 
Minimum Order Quantity12 No
Usage/ApplicationFor Outdoor Temperature and Relative Humidity Reference, Pool Room Humidity Monitoring
Model Name/NumberRHP-3S22
BrandDWYER USA
Voltage15 – 35 VDC or 15 – 29 VAC
Accuracy3%
WarrantyYAS
Output Type0 – 10 V (RH); 0 – 10 V (Temperature)
Size5-1/8″ x 2-1/4″ x 6-25/32″

RHP-3S22 DWYER Humidity Temperature Transmitter


  • RHP-3S22 – DWYER HUMIDITY/TEMPERATURE TRANSMITTER, OUTSIDE AIR WITH SINTERED FILTER, 0-10V RH & TEMP

DESCRIPTION


The Series RHP Temperature and Humidity Transmitter combine the Voltage or Current Humidity Transmitter output with a Passive Temperature Thermistor or RTD output. The polymer capacitance Humidity Sensor is Not Affected by Condensation, Fog,High Humidity, or Contaminants.

• Housing Design – Outside Air With Sintered Filter

PRODUCTS INFORMATION




  • MANUFACTURER:Dwyer
  • PART NUMBER:RHP-3S22
  • SHORT DESCRIPTION:RHP-3S22 – Humidity/Temperature Transmitter, 3%, Outside Air with Sintered Filter, 0-10V RH and Temperature Output
  • PRODUCT SERIES:Dwyer RHP Series Humidity/Temperature Transmitter
  • TEMPERATURE TYPE:Humidity/Temperature Sensors
  • SENSOR TYPE:Outdoor Sensor
  • ACCURACY:3%
  • RELATIVE HUMIDITY RANGE:0 to 100%
  • ACCURACY (TEMP):+/-0.2°C at 25°C
  • CONNECTION:Conduit Connection: 1/2″ NPS; Electrical Connection: Removable Screw Terminal Block
  • OUTPUT(S):0 – 10 V (RH); 0 – 10 V (Temperature)
  • VOLTAGE:15 – 35 VDC or 15 – 29 VAC
  • MAX TEMPERATURE:-40 to 140
  • CONSTRUCTION:Polycarbonate Housing
  • HOUSING TYPE:RHP Series OSA w/Sintered Filter
  • STANDARDS/APPROVALS:CE Approved
  • DIMENSIONS:5-1/8″ x 2-1/4″ x 6-25/32″
  • ADDITIONAL PRODUCTS OR REQUIREMENTS:Related Items: A-452, A-453, RHRS
  • USED WITH:Air Handling Economizers
  • APPLICATIONS:For Outdoor Temperature and Relative Humidity Reference, Pool Room Humidity Monitoring
 

RHP-2D22 DWYER Humidity Temperature Transmitter

 
 
Minimum Order Quantity12 No
Usage/ApplicationFor Outdoor Temperature and Relative Humidity Reference, Pool Room Humidity Monitoring
Model Name/NumberRHP-2D22
BrandDWYER USA
Voltage15 – 35 VDC or 15 – 29 VAC
Accuracy2%
WarrantyYAS
Output Type0 – 10 V (RH); 0 – 10 V (Temperature)
Size3-7/16″ x 11.59″

RHP-2D22 DWYER Humidity Temperature Transmitter

  • RHP-2D22 – DWYER HUMIDITY/TEMPERATURE TRANSMITTER, OUTSIDE AIR WITH SINTERED FILTER, 0-10V RH & TEMP

DESCRIPTION

The Series RHP Temperature and Humidity Transmitter Combine The Voltage or Current Humidity Transmitter Output With a Passive Temperature Thermistor or RTD Output. The polymer capacitance Humidity Sensor is Not Affected by Condensation, Fog,High Humidity, or Contaminants.
• Housing Design – Outside Air With Sintered Filter

PRODUCTS INFORMATION    
  • MANUFACTURER:Dwyer
  • PART NUMBER:RHP-2D22
  • SHORT DESCRIPTION:RHP-2D22 – Humidity/Temperature Transmitter, 3%, Outside Air with Sintered Filter, 0-10V RH and Temperature Output
  • PRODUCT SERIES:Dwyer RHP Series Humidity/Temperature Transmitter
  • TEMPERATURE TYPE:Humidity/Temperature Sensors
  • SENSOR TYPE:Outdoor Sensor
  • ACCURACY:2%
  • RELATIVE HUMIDITY RANGE:0 to 100%
  • ACCURACY (TEMP):+/-0.2°C at 25°C
  • CONNECTION:Conduit Connection: 1/2″ NPS; Electrical Connection: Removable Screw Terminal Block
  • OUTPUT(S):0 – 10 V (RH); 0 – 10 V (Temperature)
  • VOLTAGE:15 – 35 VDC or 15 – 29 VAC
  • MAX TEMPERATURE:-40 to 140
  • CONSTRUCTION:PBT Housing
  • HOUSING TYPE:RHP Series Duct Mount w/Membrane Filter
  • STANDARDS/APPROVALS:CE Approved
  • DIMENSIONS:3-7/16″ x 11.59″
  • ADDITIONAL PRODUCTS OR REQUIREMENTS:Related Items: A-452, A-453, RHRS
  • USED WITH:Air Handling Economizers
  • APPLICATIONS:For Outdoor Temperature and Relative Humidity Reference, Pool Room Humidity Monitoring

RHP-3O22 DWYER Humidity Temperature Transmitter

 
 
Minimum Order Quantity12 No
Usage/ApplicationFor Outdoor Temperature and Relative Humidity Reference, Pool Room Humidity Monitoring
Model Name/NumberRHP-3O22
BrandDWYER USA
Voltage15 – 35 VDC or 15 – 29 VAC
Accuracy3%
WarrantyYAS
Temperature Range-40 to 140 DegreeF
Output Type0 – 10 V (RH), 0 – 10 V (Temperature)
Part TypeDWYER Humidity Temperature Transmitter
Size5-1/8″ x 2-15/64″ x 6-25/32″
ItemNEW
Temp Range-40 to 140 DegreeF
Humidity0 – 100%
Packaging Type1

RHP-3O22 DWYER Humidity Temperature Transmitter
  • RHP-3O22 – DWYER HUMIDITY/TEMPERATURE TRANSMITTER, 3%, OSA (OUTSIDE AIR)

DESCRIPTION

The Series RHP Temperature and Humidity Transmitter Combine The Voltage or Current Humidity Transmitter Output With a Passive Temperature Thermistor or RTD output. The Polymer Capacitance Humidity Sensor is Not Affected By Condensation, Fog, High Humidity, Or Contaminants.
• Housing Design – Outside Air


PRODUCTS INFORMATION

  • MANUFACTURER:Dwyer
  • PART NUMBER:RHP-3O22
  • SHORT DESCRIPTION:RHP-3O22 – Humidity/Temperature Transmitter, 3%, OSA (Outside Air), 0-10V RH and 0-10V Temperature Output
  • PRODUCT SERIES:Dwyer RHP Series Humidity/Temperature Transmitter
  • TEMPERATURE TYPE:Humidity/Temperature Sensors
  • ACCURACY:3%
  • RELATIVE HUMIDITY RANGE:0 – 100%
  • ACCURACY (TEMP):+/-0.2°C at 25°C
  • CONNECTION:Electrical Connection: Removable Screw Terminal Block, Conduit Connection: 1/2″
  • OUTPUT(S):0 – 10 V (RH), 0 – 10 V (Temperature)
  • VOLTAGE:15 – 35 VDC or 15 – 29 VAC
  • MAX TEMPERATURE:-40 to 140°F
  • CONSTRUCTION:Polycarbonate
  • MOUNTING OPTIONS:OSA (Outside Air)
  • HOUSING TYPE:RHP Series OSA (Outside Air)
  • STANDARDS/APPROVALS:CE Approved
  • DIMENSIONS:5-1/8″ x 2-15/64″ x 6-25/32″
  • ADDITIONAL PRODUCTS OR REQUIREMENTS:Related Items: A-452, A-453, RHRS
  • APPLICATIONS:For Air Economizers, Outdoor Temperature and Relative Humidity Reference, Pool Room Humidity Monitoring
 

DWYER Series RHP Humidity Temperature Transmitter

 
 
Minimum Order Quantity12 No
Model Name/NumberDWYER Series RHP
BrandDWYER USA
Accuracy2%, 3% or 5%
Usage/ApplicationIndustrial
WarrantyYAS
Part TypeDWYER Series RHP
ItemNEW
Packaging Type1

Series RHP Humidity/Temperature Transmitter

Passive Temperature Outputs, Sintered Filter Options

The Series RHP Temperature and Humidity Transmitter combine the voltage or current humidity transmitter output with a passive temperature thermistor or RTD output. Featuring polymer capacitance humidity sensors, models are available in 2%, 3% or 5% accuracies. Duct mounted transmitters are available with an optional two-line alpha numeric LCD display.

Product Applications

Air Economizers,Outdoor Temperature and Relative Humidity Reference,Pool Room Humidity Monitoring

Model        Description

  • RHP-2D10:Duct mount 2% RH transmitter with 4-20 mA RH output.
  • RHP-2D11:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 4-20 mA temperature output.
  • RHP-2D11-LCD:Duct mount 2% RH/temperature transmitter, 4-20 mA RH output and 4-20 mA temperature output, with LCD.
  • RHP-2D1A:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K Curve A passive temperature output.
  • RHP-2D1B:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K @ 25°C thermistor temperature output.
  • RHP-2D1D:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 100 Ohm RTD Curve D passive temperature output.
  • RHP-2D1E:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 1K Ohm RTD DIN 385 temperature output.
  • RHP-2D1F:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 20K NTC thermistor temperature output.
  • RHP-2D20:Duct mount 2% RH transmitter with 0-10 VDC RH output.
  • RHP-2D22:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 0-10 VDC temperature output.
  • RHP-2D22-LCD:Duct mount 2% RH/temperature transmitter, 0-10 VDC RH output and 0-10 VDC temperature output, with LCD.
  • RHP-2D2A:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 10K Curve A passive temperature output.
  • RHP-2D2B:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 10K @ 25°C thermistor temperature output.
  • RHP-2D2D:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 100 Ohm RTD Curve D passive temperature output.
  • RHP-2D2E:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 1K Ohm RTD DIN 385 temperature output.
  • RHP-2D2F:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 20K NTC thermistor temperature output.
  • RHP-2M11:Sintered filter duct mount humidity/temperature transmitter with 2% sensor, 4 to 20 mA output for humidity and temperature.
  • RHP-2M22:Sintered filter duct mount humidity/temperature transmitter with 2% sensor, 0 to 10 V output for humidity and temperature.
  • RHP-2O10:OSA 2% RH transmitter with 4-20 mA RH output.
  • RHP-2O11:OSA 2% RH/temperature transmitter with 4-20 mA RH output and 4-20 mA temperature output.
  • RHP-2O1A:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K type III NTC thermistor temperature output.
  • RHP-2O1B:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K type II NTC thermistor temperature output.
  • RHP-2O1D:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and Pt100 RTD temperature output.
  • RHP-2O1E:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and Pt1000 RTD temperature output.
  • RHP-2O1F:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and 20K NTC thermistor temperature output.
  • RHP-2O20:OSA 2% RH transmitter with 0-10 VDC RH output.
 

Series 2-5000 Minihelic II Differential Pressure Gage Wholesaler

Series 2-5000 Minihelic II Differential Pressure Gauge

 
 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring RangeSeries 2-5000
Model Name/NumberSeries 2-5000
Usage/ApplicationDuct
ConnectionNew
HousingGlass Filled Nylon Polycarbonate Lens
ServiceAir and Compatible Gases
Accuracy+-5% of FS at 70 DegreeF (21.1 DegreeC)
Pressure Limits30 psig (2.067 bar) continuous to either pressure connection
Mounting OrientationDiaphragm in Vertical Position
Weight6 oz (170.1 g)
Agency ApprovalsMeets the technical requirements of EU Directive 2011/65/EU (RoHS II)

Series 2-5000 Minihelic II Differential Pressure
Gage

 
Combining High Accuracy, Compactness, Dependability, and Low CostCombining clean design, small size and low cost with enough accuracy for all but the most demanding applications our Series 2-5000 Minihelic® II Differential Pressure Gage offers the latest in design features for a dial type differential pressure gage. It is our most compact gage but is easy to read and can safely operate at total pressures up to 30 psig

Product Applications:
  • Room Positive Pressure Sensing
  • Local Indication on Filter Status
  • Face Velocity on Fume Hood
  • Duct Pressures
  • Cabinet Air-Purging
  • Medical Respiratory Equipment
  • Air Samplers
  • Electronic Air Cooling Systems
  • Laminar Flow Hoods
 

Dwyer 2-5000-25MM Minihelic II Differnntial Pressure Gauge 0 – 25 MM WC

 
 
Minimum Order Quantity12 Number
BrandDwyer USA
Measuring Range0 – 25 MM WC
Model Name/Number2-5000-25MM
Usage/ApplicationDuct
MaterialGlass Filled Nylon Polycarbonate Lens
Accuracy+-5% of FS at 70 DegreeF (21.1 DegreeC)
Weight6 oz (170.1 g)
Dial Size67 MM

Dwyer 2-5000-25MM Minihelic II Differnntial Pressure Gauge 0-25 MM W.C Housing Is Molded From Strong Mineral And Glass Filled Nylon. Pointer Stops of Molded Rubber Prevent Pointer Over Travel Without Damage.

Dwyer 2-5000-25mm Minihelic Ii, Differential Pressure Gauge, 0/25mm
  • Housing is molded from Strong Mineral and Glass Filled Nylon.
  • Pointer Stops of Molded Rubber Prevent Pointer Over-Travel Without Damage.
  • Full view lens is Removable and Molded of Tough Acrylic.
  • Aluminum scale litho-printed black on white, enhances Readability.
  • Red Tipped Aluminum Pointer, Rigidly Mounted to Helix is easy to see.
  • Wishbone assembly provides mounting for helix, helix bearings, and pointer shaft.
  • Jewel bearings provide virtually friction-free helix motion.
  • Helix is free to rotate in jewel bearings. It aligns with magnetic field of magnet to transmit pressure indications to pointer.
  • Zero adjustment screw, located behind the removable lens, eliminates tampering.
  • Range spring calibration clamp fixes live length of spring for proper gauge calibration and is factory set and sealed.
  • Silicone rubber diaphragm allows accurate response to a broad range of temperatures and at extremely low pressure. Incorporates blow out area for overpressure protection.
  • Diaphragm support plates of lightweight aluminum on each side of the diaphragm minimize position or attitude sensitivity and help define pressure area.
  • Flat leaf range spring reacts to pressure on the diaphragm. Live length is adjustable for calibration. Small amplitude of motion minimizes inaccuracies and assures long life.
  • Low pressure tap connects to rear chamber.
  • Coil spring link provides a resilient connection between the diaphragm and the range spring.
  • Ceramic magnet mounted on a molded bracket at the end of the range spring rotates the helix without direct mechanical linkage.
  • High pressure tap connects with the front chamber through passageway in the plastic case and a sealing ring molded into the edgeof the diaphragm.
 

Dwyer 2-5000-50MM Minihelic II Differential Pressure Gauge 0-50 MM WC

 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring Range0-50 MM WC
Model Name/NumberDwyer 2-5000-50MM
Usage/ApplicationDuct
MaterialGlass Filled Nylon Polycarbonate Lens
Accuracy+-5% of FS at 70 DegreeF (21.1 DegreeC)
Weight6 oz (170.1 g)
Size67 MM

Dwyer 2-5000-50MM Minihelic II Differnntial Pressure Gauge 0-50 MM w.c Housing Is Molded From Strong Mineral And Glass Filled Nylon. Pointer Stops of Molded Rubber Prevent Pointer Over Travel Without Damage.

Dwyer 2-5000-50mm Minihelic Ii, Differential Pressure Gauge, 0/50mm
  • Housing is molded from Strong Mineral and Glass Filled Nylon.
  • Pointer Stops of Molded Rubber Prevent Pointer Over-Travel Without Damage.
  • Full view lens is Removable and Molded of Tough Acrylic.
  • Aluminum scale litho-printed black on white, enhances Readability.
  • Red Tipped Aluminum Pointer, Rigidly Mounted to Helix is easy to see.
  • Wishbone assembly provides mounting for helix, helix bearings, and pointer shaft.
  • Jewel bearings provide virtually friction-free helix motion.
  • Helix is free to rotate in jewel bearings. It aligns with magnetic field of magnet to transmit pressure indications to pointer.
  • Zero adjustment screw, located behind the removable lens, eliminates tampering.
  • Range spring calibration clamp fixes live length of spring for proper gauge calibration and is factory set and sealed.
  • Silicone rubber diaphragm allows accurate response to a broad range of temperatures and at extremely low pressure. Incorporates blow out area for overpressure protection.
  • Diaphragm support plates of lightweight aluminum on each side of the diaphragm minimize position or attitude sensitivity and help define pressure area.
  • Flat leaf range spring reacts to pressure on the diaphragm. Live length is adjustable for calibration. Small amplitude of motion minimizes inaccuracies and assures long life.
  • Low pressure tap connects to rear chamber.
  • Coil spring link provides a resilient connection between the diaphragm and the range spring.
  • Ceramic magnet mounted on a molded bracket at the end of the range spring rotates the helix without direct mechanical linkage.
  • High pressure tap connects with the front chamber through passageway in the plastic case and a sealing ring molded into the edgeof the diaphragm.
 

Dwyer 2-5000-100MM Minihelic II Differential Pressure Gauge 0-100 MM WC

 
 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring Range0-100 MM WC
Model Name/NumberDwyer 2-5000-100MM
Usage/ApplicationDuct
MaterialGlass Filled Nylon Polycarbonate Lens
Accuracy+-5% of FS at 70 DegreeF (21.1 DegreeC)
Dial Size67 MM
Pressure Limits30 psig (2.067 bar) Continuous to Either Pressure Connection
Temperature Limits20 to 120 deg F (-6.67 to 48.9 deg C)

Dwyer 2-5000-100MM Minihelic II Differnntial Pressure Gauge 0-100 MM w.c Housing Is Molded From Strong Mineral And Glass Filled Nylon. Pointer Stops of Molded Rubber Prevent Pointer Over Travel Without Damage.

Dwyer 2-5000-100mm Minihelic Ii, Differential Pressure Gauge, 0/100mm
  • Housing is molded from Strong Mineral and Glass Filled Nylon.
  • Pointer Stops of Molded Rubber Prevent Pointer Over-Travel Without Damage.
  • Full view lens is Removable and Molded of Tough Acrylic.
  • Aluminum scale litho-printed black on white, enhances Readability.
  • Red Tipped Aluminum Pointer, Rigidly Mounted to Helix is easy to see.
  • Wishbone assembly provides mounting for helix, helix bearings, and pointer shaft.
  • Jewel bearings provide virtually friction-free helix motion.
  • Helix is free to rotate in jewel bearings. It aligns with magnetic field of magnet to transmit pressure indications to pointer.
  • Zero adjustment screw, located behind the removable lens, eliminates tampering.
  • Range spring calibration clamp fixes live length of spring for proper gauge calibration and is factory set and sealed.
  • Silicone rubber diaphragm allows accurate response to a broad range of temperatures and at extremely low pressure. Incorporates blow out area for overpressure protection.
  • Diaphragm support plates of lightweight aluminum on each side of the diaphragm minimize position or attitude sensitivity and help define pressure area.
  • Flat leaf range spring reacts to pressure on the diaphragm. Live length is adjustable for calibration. Small amplitude of motion minimizes inaccuracies and assures long life.
  • Low pressure tap connects to rear chamber.
  • Coil spring link provides a resilient connection between the diaphragm and the range spring.
  • Ceramic magnet mounted on a molded bracket at the end of the range spring rotates the helix without direct mechanical linkage.
  • High pressure tap connects with the front chamber through passageway in the plastic case and a sealing ring molded into the edgeof the diaphragm.
 

Dwyer 2-5000-125PA Minihelic II Differential Pressure Gauge 0-125 Pa

 
 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring Range0-125 Pa
Model Name/NumberDwyer 2-5000-125PA
Usage/ApplicationIndustrial
Accuracy+-5% of FS at 70 deg F (21.1 deg C)
Weight6 oz (170.1 g)
Pressure Limits30 psig (2.067 bar) continuous to either pressure connection

Dwyer 2-5000-125PA Minihelic II Differential Pressure Gauge 0-125 Pa
Housing is Molded From Strong Mineral And Glass Filled Nylon. Pointer Stops Of Molded Rubber Prevent Pointer Over Travel Without Damage.

Dwyer 2-5000-125pa Minihelic Ii, Differential Pressure Gauge, 0/125 Pa
  • Housing is molded from strong mineral and glass filled nylon.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • Full view lens is removable and molded of tough acrylic.
  • Aluminum scale litho-printed black on white, enhances readability.
  • Red tipped aluminum pointer, rigidly mounted to helix is easy to see.
  • Wishbone assembly provides mounting for helix, helix bearings, and pointer shaft.
  • Jewel bearings provide virtually friction-free helix motion.
  • Helix is free to rotate in jewel bearings. It aligns with magnetic field of magnet to transmit pressure indications to pointer.
  • Zero adjustment screw, located behind the removable lens, eliminates tampering.
  • Range spring calibration clamp fixes live length of spring for proper gauge calibration and is factory set and sealed.
  • Silicone rubber diaphragm allows accurate response to a broad range of temperatures and at extremely low pressure. Incorporates blow out area for overpressure protection.
  • Diaphragm support plates of lightweight aluminum on each side of the diaphragm minimize position or attitude sensitivity and help define pressure area.
  • Flat leaf range spring reacts to pressure on the diaphragm. Live length is adjustable for calibration. Small amplitude of motion minimizes inaccuracies and assures long life.
  • Low pressure tap connects to rear chamber.
  • Coil spring link provides a resilient connection between the diaphragm and the range spring.
  • Ceramic magnet mounted on a molded bracket at the end of the range spring rotates the helix without direct mechanical linkage.
  • High pressure tap connects with the front chamber through passageway in the plastic case and a sealing ring molded into the edgeof the diaphragm.
 

Dwyer 2-5000-250PA Minihelic II Differential Pressure Gauge 0-250 Pa

 
 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring Range0-250 Pa
Model Name/NumberDwyer 2-5000-250PA
Usage/ApplicationIndustrial
Accuracy+-5% of FS at 70 DegreeF (21.1 DegreeC)
Weight6 oz (170.1 g)
Dial Size63 mm
Pressure Limits30 psig (2.067 bar) continuous to either pressure connection


Dwyer 2-5000-250PA Minihelic II Differential Pressure Gauge 0-250 Pa
Housing Is Molded From Strong Mineral And Glass Filled Nylon. Pointer Stops of Molded Rubber Prevent Pointer Over Travel Without Damage.

Dwyer 2-5000-250pa Minihelic Ii, Differential Pressure Gauge, 0/250 Pa

  • Housing is molded from strong mineral and glass filled nylon.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • Full view lens is removable and molded of tough acrylic.
  • Aluminum scale litho-printed black on white, enhances readability.
  • Red tipped aluminum pointer, rigidly mounted to helix is easy to see.
  • Wishbone assembly provides mounting for helix, helix bearings, and pointer shaft.
  • Jewel bearings provide virtually friction-free helix motion.
  • Helix is free to rotate in jewel bearings. It aligns with magnetic field of magnet to transmit pressure indications to pointer.
  • Zero adjustment screw, located behind the removable lens, eliminates tampering.
  • Range spring calibration clamp fixes live length of spring for proper gauge calibration and is factory set and sealed.
  • Silicone rubber diaphragm allows accurate response to a broad range of temperatures and at extremely low pressure. Incorporates blow out area for overpressure protection.
  • Diaphragm support plates of lightweight aluminum on each side of the diaphragm minimize position or attitude sensitivity and help define pressure area.
  • Flat leaf range spring reacts to pressure on the diaphragm. Live length is adjustable for calibration. Small amplitude of motion minimizes inaccuracies and assures long life.
  • Low pressure tap connects to rear chamber.
  • Coil spring link provides a resilient connection between the diaphragm and the range spring.
  • Ceramic magnet mounted on a molded bracket at the end of the range spring rotates the helix without direct mechanical linkage.
  • High pressure tap connects with the front chamber through passageway in the plastic case and a sealing ring molded into the edgeof the diaphragm.

Dwyer 2-5000-500PA Minihelic II Differential Pressure Gauge 0-500 Pa

 
 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring Range0-500 Pa
Model Name/NumberDwyer 2-5000-500PA
Usage/ApplicationIndustrial
Accuracy+-5% of FS at 70 DegreeF (21.1 DegreeC)
Temperature20 to 120 Degree F (-6.67 to 48.9 Deg C)
Weight6 oz (170.1 g)
Size63 MM
Pressure Limits30 psig (2.067 bar) continuous to either pressure connection

Dwyer 2-5000-500PA Minihelic II Differential Pressure Gauge 0-500 Pa
Housing Is Molded From Strong Mineral And Glass Filled Nylon. Pointer Stops of Molded Rubber Prevent Pointer Over Travel Without Damage.

Dwyer 2-5000-500pa Minihelic Ii, Differential Pressure Gauge, 0/500pa
  • Housing is molded from strong mineral and glass filled nylon.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • Full view lens is removable and molded of tough acrylic.
  • Aluminum scale litho-printed black on white, enhances readability.
  • Red tipped aluminum pointer, rigidly mounted to helix is easy to see.
  • Wishbone assembly provides mounting for helix, helix bearings, and pointer shaft.
  • Jewel bearings provide virtually friction-free helix motion.
  • Helix is free to rotate in jewel bearings. It aligns with magnetic field of magnet to transmit pressure indications to pointer.
  • Zero adjustment screw, located behind the removable lens, eliminates tampering.
  • Range spring calibration clamp fixes live length of spring for proper gauge calibration and is factory set and sealed.
  • Silicone rubber diaphragm allows accurate response to a broad range of temperatures and at extremely low pressure. Incorporates blow out area for overpressure protection.
  • Diaphragm support plates of lightweight aluminum on each side of the diaphragm minimize position or attitude sensitivity and help define pressure area.
  • Flat leaf range spring reacts to pressure on the diaphragm. Live length is adjustable for calibration. Small amplitude of motion minimizes inaccuracies and assures long life.
  • Low pressure tap connects to rear chamber.
  • Coil spring link provides a resilient connection between the diaphragm and the range spring.
  • Ceramic magnet mounted on a molded bracket at the end of the range spring rotates the helix without direct mechanical linkage.
  • High pressure tap connects with the front chamber through passageway in the plastic case and a sealing ring molded into the edgeof the diaphragm.
 

Dwyer 2-5000-1KPA Minihelic II Differential Pressure Gauge 0-1 KPA

 
 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring Range0-1 KPA
Model Name/NumberDwyer 2-5000-1KPA
Usage/ApplicationIndustrial
Accuracy+-5% of FS at 70 DegreeF (21.1 DegreeC)
Weight6 oz (170.1 g)
Dial Size63 MM
Pressure Limits30 psig (2.067 bar) continuous to either pressure connection
Temperature Limits20 to 120 deg F (-6.67 to 48.9 deg C)
Mounting OrientationDiaphragm in Vertical Position


Dwyer 2-5000-1KPA Minihelic II Differential Pressure Gauge 0-1 KPA 
Housing Is Molded From Strong Mineral And Glass Filled Nylon. Pointer Stops of Molded Rubber Prevent Pointer Over Travel Without Damage.

Dwyer 2-5000-1kpa Minihelic Ii, Differential Pressure Gauge, 0/1 Kpa

  • Housing is molded from strong mineral and glass filled nylon.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • Full view lens is removable and molded of tough acrylic.
  • Aluminum scale litho-printed black on white, enhances readability.
  • Red tipped aluminum pointer, rigidly mounted to helix is easy to see.
  • Wishbone assembly provides mounting for helix, helix bearings, and pointer shaft.
  • Jewel bearings provide virtually friction-free helix motion.
  • Helix is free to rotate in jewel bearings. It aligns with magnetic field of magnet to transmit pressure indications to pointer.
  • Zero adjustment screw, located behind the removable lens, eliminates tampering.
  • Range spring calibration clamp fixes live length of spring for proper gauge calibration and is factory set and sealed.
  • Silicone rubber diaphragm allows accurate response to a broad range of temperatures and at extremely low pressure. Incorporates blow out area for overpressure protection.
  • Diaphragm support plates of lightweight aluminum on each side of the diaphragm minimize position or attitude sensitivity and help define pressure area.
  • Flat leaf range spring reacts to pressure on the diaphragm. Live length is adjustable for calibration. Small amplitude of motion minimizes inaccuracies and assures long life.
  • Low pressure tap connects to rear chamber.
  • Coil spring link provides a resilient connection between the diaphragm and the range spring.
  • Ceramic magnet mounted on a molded bracket at the end of the range spring rotates the helix without direct mechanical linkage.
  • High pressure tap connects with the front chamber through passageway in the plastic case and a sealing ring molded into the edgeof the diaphragm.

Dwyer 2-5000-3KPA Minihelic II Differential Pressure Gauge 0-3 KPA

 
 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring Range0-3 KPA
Model Name/NumberDwyer 2-5000-3KPA
Usage/ApplicationIndustrial
Accuracy+-5% of FS at 70 DegreeF (21.1 DegreeC)
Temperature20 to 120 DegreeF (-6.67 to 48.9 DegreeC)
Dial Size63 MM
MountingDiaphragm In Vertical Position
Pressure Limits30 psig (2.067 bar) continuous to either pressure connection

Dwyer 2-5000-3KPA Minihelic II Differential Pressure Gauge 0-3 KPA
Housing Is Molded From Strong Mineral And Glass Filled Nylon. Pointer Stops of Molded Rubber Prevent Pointer Over Travel Without Damage.

Dwyer 2-5000-3kpa Minihelic Ii, Differential Pressure Gauge, 0/3 Kpa
  • Housing is molded from strong mineral and glass filled nylon.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • Full view lens is removable and molded of tough acrylic.
  • Aluminum scale litho-printed black on white, enhances readability.
  • Red tipped aluminum pointer, rigidly mounted to helix is easy to see.
  • Wishbone assembly provides mounting for helix, helix bearings, and pointer shaft.
  • Jewel bearings provide virtually friction-free helix motion.
  • Helix is free to rotate in jewel bearings. It aligns with magnetic field of magnet to transmit pressure indications to pointer.
  • Zero adjustment screw, located behind the removable lens, eliminates tampering.
  • Range spring calibration clamp fixes live length of spring for proper gauge calibration and is factory set and sealed.
  • Silicone rubber diaphragm allows accurate response to a broad range of temperatures and at extremely low pressure. Incorporates blow out area for overpressure protection.
  • Diaphragm support plates of lightweight aluminum on each side of the diaphragm minimize position or attitude sensitivity and help define pressure area.
  • Flat leaf range spring reacts to pressure on the diaphragm. Live length is adjustable for calibration. Small amplitude of motion minimizes inaccuracies and assures long life.
  • Low pressure tap connects to rear chamber.
  • Coil spring link provides a resilient connection between the diaphragm and the range spring.
  • Ceramic magnet mounted on a molded bracket at the end of the range spring rotates the helix without direct mechanical linkage.
  • High pressure tap connects with the front chamber through passageway in the plastic case and a sealing ring molded into the edgeof the diaphragm
 

Dwyer 2-5205-5PSI Minihelic II Differential Pressure Gauge 0-5 PSI

 
 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring Range0-5 PSI
Model Name/NumberDwyer 2-5205-5PSI
Usage/ApplicationIndustrial
Accuracy+-5% of FS at 70 DegreeF (21.1 DegreeC)
Temperature20 to 120 DegreeF (-6.67 to 48.9 DegreeC)
Weight6 oz (170.1 g)
Dial Size63 MM
Pressure Limits30 psig (2.067 bar) continuous to either pressure connection
Temperature Limits20 to 120 deg F (-6.67 to 48.9 deg C)
Mounting OrientationDiaphragm in Vertical Position

Dwyer 2-5205-5PSI Minihelic II Differential Pressure Gauge 0-5 PSI
Designed For Panel Mounting in a 2-5/8″ Diameter Hole. Pressure Connections Are Barbed. Dwyer 2-5205 Minihelic II Differential Pressure Gauge
The Dwyer 2-5205 Differential Pressure Gauge has barbed connections and a range of 0-5 psi. Combining clean design , small size and low cost with enough accuracy for all but the most demanding applications our Minihelic® II gauge offers the latest in design Features for a dial type differential pressure gauge. It is our most compact gauge but is easy to read and can safely operate at total pressures up to 30 psig. The Minihelic® II gauge is designed for panel mounting in a single 2-5/8″ diameter hole. Standard pressure connections are barbed fittings for 3/16″ ID tubing; optional 1/8″ male NPT connections are also available. Over-Pressure protection is built into the Minihelic® II gauge by means of a blow-out membrane molded in conjunction with the diaphragm. Accidental over-ranging up to the rated total pressure will not damage the gauge. With removable lens and rear housing, the gauge may be easily serviced at minimum cost. With the housing molded from mineral and glass filled nylon and the lens molded from acrylic, the gauge will withstand rough use and exposure as well as high total pressure. The 5% accuracy and low cost of the Minihelic® II gauge make it well-suited for a wide variety of OEM and user applications. OEM applications include cabinet air purging, medical respiratory therapy equipment, air samplers, laminar flow hoods, and electronic air cooling systems. As an air filter gauge, the Minihelic® II gauge finds many end use applications on large stationary engines, compressors, ventilators, and air handling units. The Minihelic® II gauge is suitable for many of the same applications as the Magnehelic® gauge where the greater accuracy, sensitivity, and higher and lower differential pressure ranges of the Magnehelic® gauge are not required.
 

Dwyer 2-5000-0 Minihelic II Differential Pressure Gauge 0-0.5 INCH

 
 
Minimum Order Quantity10 Number
BrandDwyer USA
Measuring Range0-0.5 inch
Model Name/NumberDwyer 2-5000-0
Usage/ApplicationIndustrial
Accuracy+-5% of FS at 70 deg F (21.1 deg C)
Temperature20 to 120 DegreeF (-6.67 to 48.9 DegreeC)
Weight6 oz (170.1 g)
Dial Size63 MM
Pressure Limits30 psig (2.067 bar) continuous to either pressure connection


Dwyer 2-5000-0 Minihelic II Differential Pressure Gauge 0-0.5 INCH Housing Is Molded From Strong Mineral And Glass Filled Nylon. Pointer Stops of Molded Rubber Prevent Pointer Over Travel Without Damage.

Dwyer 2-5000-0 Minihelic Ii, Differential Pressure Gauge, 0/0.5

  • Housing is molded from strong mineral and glass filled nylon.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • Full view lens is removable and molded of tough acrylic.
  • Aluminum scale litho-printed black on white, enhances readability.
  • Red tipped aluminum pointer, rigidly mounted to helix is easy to see.
  • Wishbone assembly provides mounting for helix, helix bearings, and pointer shaft.
  • Jewel bearings provide virtually friction-free helix motion.
  • Helix is free to rotate in jewel bearings. It aligns with magnetic field of magnet to transmit pressure indications to pointer.
  • Zero adjustment screw, located behind the removable lens, eliminates tampering.
  • Range spring calibration clamp fixes live length of spring for proper gauge calibration and is factory set and sealed.
  • Silicone rubber diaphragm allows accurate response to a broad range of temperatures and at extremely low pressure. Incorporates blow out area for overpressure protection.
  • Diaphragm support plates of lightweight aluminum on each side of the diaphragm minimize position or attitude sensitivity and help define pressure area.
  • Flat leaf range spring reacts to pressure on the diaphragm. Live length is adjustable for calibration. Small amplitude of motion minimizes inaccuracies and assures long life.
  • Low pressure tap connects to rear chamber.
  • Coil spring link provides a resilient connection between the diaphragm and the range spring.
  • Ceramic magnet mounted on a molded bracket at the end of the range spring rotates the helix without direct mechanical linkage.
  • High pressure tap connects with the front chamber through passageway in the plastic case and a sealing ring molded into the edgeof the diaphragm.

Series 251 Wet Differential Pressure Transmitter

Sensocon Series 251-04 Wet Differential Pressure Transmitter

 
 
BrandSensocon
Accuracy+/- 0.25% F.S.
Operating Temperature-40o to 185o F (-40o to 85o C)
Over PressurePositive – 2x F.S.; negative – 1x F.S.
Working Pressure1000 PSI (7MPa)
Stability0.5% F.S/yr
Response Time100 ms

The Series 251 wet/wet differential pressure transmitter utilizes a double diaphragm
sensor technology that outperforms standard double sensor products in accuracy,
reliability and static operating pressure. This differential pressure sensing technology
offers 0.25% accuracy with static operating pressures up to 1000 PSI (7 MPa). The
Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP
65) standards. The transmitter also offers exceptional field flexibility with a 5:1 turn
down and comes standard with a certificate of calibration.
 

Sensocon Series 251-05 Wet Differential Pressure Transmitter

 
 
BrandSensocon
Measuring RangeSeries 251-05
Model Name/NumberSeries 251-05
Usage/ApplicationIndustrial
ConnectionNew
Model No.Series 251
Accuracy+/- 0.25% F.S.
Over PressurePositive – 2x F.S.; negative – 1x F.S.
Working Pressure1000 PSI (7MPa)
Power Supply12-36 VDC
Response Time100 ms

Sensocon USA Wet/Wet Differential Pressure Transmitter Series 251-05

The Series 251 wet/wet differential pressure transmitter utilizes a double diaphragm sensor technology that outperforms standard double sensor products in accuracy, reliability and static operating pressure. This differential pressure sensing technology offers 0.25% accuracy with static operating pressures up to 1000 PSI. The Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP 65) standards. The transmitter also offers exceptional field flexibility with a 5:1 turn down and comes standard with a certificate of calibration.

Media compatibility:
Gas and Liquids compatible with 316SS
Accuracy:
+/- 0.25% F.S.
Over Pressure:
positive – 2x f.S.; negative-1x F.S.
Working Pressure:
1000 PSI (7MPa)
Temperature Limits:
Operating: -40° to 185°F (-40° to 85°C)
Compensated: -4° to 158°F (-20° to 70°C)
Thermal Effect:
+/- 0.028% FS/°F (0.050%FS/°C)
Stability:
+/- 0.5% FS/year
Power Supply:
12-30 VDC
Output Signal:
4-20 mA, 2-wire
Electrical Connetction:
mini DIN 43650
Response Time:
100 ms
Turn Down:
5:1
Enclosure Rating:
NEMA 4X (IP 65)
Process Connection:
1/4″ NPT female, optional 1/4″ G
Mounting Position Effect:
0.1% F.S., can be corrected by zero adjust

Model Number Range
251-05 0 – 50 PSI ( 344.7 kPa )
 

Sensocon Series 251-01 Wet Differential Pressure Transmitter

 
 
Minimum Order Quantity1 Number
BrandSensocon
Accuracy+/- 0.25% F.S.
Response Time100 ms
Media CompatibilityGas and Liquids compatible with 316SS
Over PressurePositive – 2x F.S.; negative – 1x F.S.
Working Pressure1000 PSI (7MPa)
Thermal Effect0.028%/o F (0.050%/o C)
Power Supply12-36 VDC

Sensocon USA Series 251-01 Wet Differential Pressure Transmitter

The Series 251 Wet/Wet Differential Pressure Transmitter utilizes a double diaphragm sensor technology that outperforms standard double sensor products in accuracy, reliability and static operating pressure. This differential pressure sensing technology offers 0.25% accuracy with static operating pressures up to 1000 PSI. The Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP 65) standards. The transmitter also offers exceptional field flexibility with a 5:1 turn down and comes standard with a certificate of calibration


Media compatibility:Gas and Liquids compatible with 316SSAccuracy:+/- 0.25% F.S.Over Pressure:positive – 2x f.S.; negative-1x F.S.Working Pressure:1000 PSI (7MPa)Temperature Limits:Operating: -40° to 185°F (-40° to 85°C)
Compensated: -4° to 158°F (-20° to 70°C)Thermal Effect:+/- 0.028% FS/°F (0.050%FS/°C)Stability:+/- 0.5% FS/yearPower Supply:12-30 VDCOutput Signal:4-20 mA, 2-wireElectrical Connetction:mini DIN 43650Response Time:100 msTurn Down:5:1Enclosure Rating:NEMA 4X (IP 65)Process Connection:1/4″ NPT female, optional 1/4″ GMounting Position Effect:

0.1% F.S., can be corrected by zero adjust

Model NumberRange
251-010 – 5 PSI ( 34.5 kPa )
 

Sensocon Series 251-02 Wet Differential Pressure Transmitter

 
 
BrandSensocon
Accuracy+/- 0.25% F.S.
Media CompatibilityGas and Liquids compatible with 316SS
Working Pressure1000 PSI (7MPa)
Thermal Effect0.028%/o F (0.050%/o C)
Power Supply12-36 VDC
Output Signal4-20 mA, 2 wire


The Series 251 wet/wet differential pressure transmitter utilizes a double diaphragm
sensor technology that outperforms standard double sensor products in accuracy,
reliability and static operating pressure. This differential pressure sensing technology
offers 0.25% accuracy with static operating pressures up to 1000 PSI (7 MPa). The
Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP
65) standards. The transmitter also offers exceptional field flexibility with a 5:1 turn
down and comes standard with a certificate of calibration

Sensocon Series 251-08 Wet Differential Pressure Transmitter

 
 
BrandSensocon
Model No.SERIES 251-08
Accuracy+/- 0.25% F.S.
Media CompatibilityGas and Liquids compatible with 316SS
Over PressurePositive – 2x F.S.; negative – 1x F.S.
Working Pressure1000 PSI (7MPa)
Thermal Effect0.028%/o F (0.050%/o C)
Power Supply12-36 VDC
Response Time100 ms

The Series 251 wet/wet differential pressure transmitter utilizes a double diaphragm
sensor technology that outperforms standard double sensor products in accuracy,
reliability and static operating pressure. This differential pressure sensing technology
offers 0.25% accuracy with static operating pressures up to 1000 PSI (7 MPa). The
Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP
65) standards. The transmitter also offers exceptional field flexibility with a 5:1 turn
down and comes standard with a certificate of calibration.
 

Sensocon Series 251-07 Wet Differential Pressure Transmitter

 
 
BrandSensocon
Accuracy+/- 0.25% F.S.
Media CompatibilityGas and Liquids compatible with 316SS
Working Pressure1000 PSI (7MPa)
Thermal Effect0.028%/o F (0.050%/o C)
Stability0.5% F.S/yr
Power Supply12-36 VDC


The Series 251 wet/wet differential pressure transmitter utilizes a double diaphragm
sensor technology that outperforms standard double sensor products in accuracy,
reliability and static operating pressure. This differential pressure sensing technology
offers 0.25% accuracy with static operating pressures up to 1000 PSI (7 MPa). The
Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP
65) standards. The transmitter also offers exceptional field flexibility with a 5:1 turn
down and comes standard with a certificate of calibration.

Sensocon Series 251-06 Wet Differential Pressure Transmitter

 
 
BrandSensocon
Accuracy+/- 0.25% F.S.
Media CompatibilityGas and Liquids compatible with 316SS
Working Pressure1000 PSI (7MPa)
Power Supply12-36 VDC
Response Time100 ms

The Series 251 wet/wet differential pressure transmitter utilizes a double diaphragm
sensor technology that outperforms standard double sensor products in accuracy,
reliability and static operating pressure. This differential pressure sensing technology
offers 0.25% accuracy with static operating pressures up to 1000 PSI (7 MPa). The
Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP
65) standards. The transmitter also offers exceptional field flexibility with a 5:1 turn
down and comes standard with a certificate of calibration.
 

Sensocon Series 251-03 Wet Differential Pressure Transmitter

 
 
BrandSensocon
Accuracy+/- 0.25% F.S.
Over PressurePositive – 2x F.S.; negative – 1x F.S.
Working Pressure1000 PSI (7MPa)
Thermal Effect0.028%/o F (0.050%/o C)
Stability0.5% F.S/yr
Output Signal4-20 mA, 2 wire

The Series 251 Wet/Wet Differential Pressure Transmitter utilizes a double diaphragm sensor technology that outperforms standard double sensor products in accuracy, reliability and static operating pressure. This differential pressure sensing technology offers 0.25% accuracy with static operating pressures up to 1000 PSI. The Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP 65) standards. The transmitter also offers exceptional field flexibility with a 5:1 turn down and comes standard with a certificate of calibration
 

Series 251 Wet Differential Pressure Transmitter

 
 
Accuracy+/- 0.25%
Response Time10 ms
Working Pressure1000 PSI (7MPa)
Power Supply12-36 VDC
Housing Material316 SS
ProtectionIP 65
Output Signal4-20 mA, 2-wire


The Series 251 Wet/Wet Differential Pressure Transmitter utilizes a double diaphragm sensor technology that outperforms standard double sensor products in accuracy, reliability and static operating pressure. This differential pressure sensing technology offers 0.25% accuracy with static operating pressures up to 1000 PSI. The Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP 65) standards. The transmitter also offers exceptional field flexibility with a 5:1 turn down and comes standard with a certificate of calibration.

Model NumberRange
251-010 – 5 PSI ( 34.5 kPa )
251-020 – 10 PSI ( 68.9 kPa )
251-030 – 15 PSI ( 103 kPa )
251-040 – 30 PSI ( 206.8 kPa )
251-050 – 50 PSI ( 344.7 kPa )
251-060 – 100 PSI ( 689.5 kPa )
251-070 – 150 PSI ( 1034 kPa )
251-080 – 300 PSI ( 2068 kPa )

ENVIRO TECH / Replacement Filter In Assam

www.envirotechdelhi.info

ENVIRO TECH / Replacement Filter In Assam

 

With a Firm Commitment To Quality and Customer Satisfaction, We Specialize In The Manufacturing And Supply of ENVIRO TECH Replacement Filters Across INDIA. Our Diverse Product Range Includes a Complete Line of Filters And Cartridges Designed For Low, Medium, And High-Pressure Applications. Each Filter is Available In Various Media Efficiency Options, Ensuring Optimal Performance Tailored To Your Specific Application Needs.

A Sole Proprietorship (Individual) Based Company, Actively Engaged In Manufacturing And Supplying The Best Quality Array Of Air Filter, Oil Filter, Gas Filter, Fuel Filter, Hydraulic Filter etc.

WE ARE MANUFACTURER FOR INDUSTRIAL FILTER LIKE THIS ENVIRO TECH,HYDAC,REXROTH, PALL,Triveni,PARKER,MP FILTRI,MAHLE, STUFF, FILTREC,INTERNORMAN, EPE & BHAGWATI REPLACEMENT ALL TYPE FILTER.


MATERIAL
 

  • Wire Mesh
  • Glass Fibre Paper
  • 1 Micron To 1000 Micron


INDUSTRIAL USES

 

  • POWER PLANT
  • CEMENT PLANT
  • STEEL PLANT
  • FERTILIZER
  • TEXTILE

Additional Information:

  • Item Code: ENVIRO TECH / Replacement Filter In Assam
  • WhatsApp No.9871034100,9868958924,9650264867,9716640145,8368866030,8368801023
  • www.envirotechindia.co.in
  • www.envirotechdelhi.in
  • www.envirotechdelhi.net
  • www.envirotechindia.info
  • www.envirotechdelhi.info
  • www.envirotechindia.net
  • www.envirotechdelhi.co.in

www.envirotechdelhi.info

Setra USA Model 265 Differential Pressure Transducer Wholesaler

Setra Model 265 Differential Pressure Transducer Range 0- 50 Pac

 
 
BrandSetra
Frequency Range0- 50 PAC
Usage/ApplicationStatic duct and cleanroom pressures
Output Voltage9 to 30VDC
Automation GradeManual
Weight0.09 Kg
Size/Dimension3.16 Inch w x 1.89 Inch h x 1.64 Inch d

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring

More Information:
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 50 PAC 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 25 Inch

 
 
BrandSetra
Frequency Range0- 25 inch
Usage/ApplicationVariable Air Volume and Fan Control
Automation GradeManual
Weight0.09 Kg
Output Type9 to 30VDC
Size/Dimension3.16 Inch w x 1.89 Inch h x 1.64 Inch d

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 25 INCH 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 10 Inch

 
 
Model Number2651-010WDACT1C
BrandSetra
Frequency Range0- 10 inch
Usage/ApplicationHVAC systems
Product Weight0.09 Kg
Output Type9 to 30VDC @ 20 mA

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year

Features:
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring

More Informations:
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0-10 Inch 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 2.5 Inch

 
 
Minimum Order Quantity1 Number
ApplicationHVAC systems
Model Number265
BrandSetra USA
Frequency Range0- 2.5 INCH
Usage/ApplicationEnergy management systems
Display Typeno
Automation GradeManual
Product Weight0.09 Kg
Range0- 2.5 INCH
Output Type9 to 30VDC
Weight0.09 Kg
Warrantyyas
Size/Dimension3.16 Inch w x 1.89 Inch h x 1.64 Inch d
Net Weight0.09 Kg
Certification RequiredYes
ApplicationsVariable Air Volume and Fan Control (VAV)
I deal inNew Only

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K¿¿¿, 4-20mA @ 750¿¿¿ (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150¿¿¿ (-18 to 65¿¿¿)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 2.5 INCH 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 1 Inch

 
 
BrandSetra
Frequency Range0- 1 inch
Usage/ApplicationEnergy management systems
Automation GradeManual
Product Weight0.09 Kg
Output Type9 to 30 VDC
Size/Dimension3.16 Inch w x 1.89 Inch h x 1.64 Inch d

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 1 INCH 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 0.5 Inch

 
 
BrandSetra
Frequency Range0- 0.5 inch
Usage/ApplicationStatic duct and cleanroom pressures
Automation GradeManual
Product Weight0.09 Kg
Output Type9 to 30VDC
Size/Dimension3.16 Inch w x 1.89 Inch h x 1.64 Inch d

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 0.5 INCH 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 25 Pac

 
 
BrandSetra
Frequency Range0- 25 PAC
Usage/ApplicationEnvironmental pollution control
Output Voltage9 to 30VDC
Automation GradeManual
Product Weight0.09 Kg
Size/Dimension3.16 Inch w x 1.89 Inch h x 1.64 Inch d

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring

More Information:
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 25 PAC 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 50 Inch

 
 
BrandSetra
Frequency Range0- 50 inch
Usage/ApplicationHVAC systems
Product Weight0.09 Kg
Output Type9 to 30VDC

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K¿¿¿, 4-20mA @ 750¿¿¿ (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150¿¿¿ (-18 to 65¿¿¿)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year

Features:
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring

More Information:
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 50 INCH 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 5 Inch

 
 
BrandSetra
Frequency Range0- 5 inch
Usage/ApplicationStatic duct and cleanroom pressures
Product Weight0.09 Kg
Output Type9 to 30 VDC

Supply Voltage

  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 5 INCH 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer

 
 
BrandSetra
Automation GradeManual
Weight3 ounces
Power Supply0-5 VDC
Usage/ApplicationSwitches
Output Voltage4-20 mA
Pressure12 mA
Electrical Load0 to 800 Ohms
Pressure Fittings1/4″ Fitting

Setra Systems 265 pressure transducers sense Differential or gauge static pres sures andconvert this pressure difference to a proportional electrical output.The 265 is offered witha high level 0-5 VDC output or a 4-20 mA output.It is also offered with 0-5 or 0-10 VDC output in the 24 VAC excitation version. Used in Building Energy Management Systems, these transducers are capable of measuring pressures and fl ows with the accuracy necessary for proper building pressurization and air flow control. The 265 Series very low pressure transducers are available for air pressure ranges as low as 0.25 in. WC full scale up to 100 in. WC full scale. Static accuracy is±1% full scale in normal ambient temperature environments.The units are temperature compensated to less than ±0.033% FS/oF of thermal error over the temperature range of 0oF to +150oF. The Model 265utilizes an improved all stainless steel micro-tig welded sensor. The tensioned stainless steel diaphragm and insulated stainless steel electrode,positioned close tothe diaphragm, form a variable capacitor. Positive pressure moves the diaphragm toward the electrode, increasing the capacitance. A decrease in pressure moves the diaphragm awayfrom the electrode, decreasing the capacitance.The change in capacitance is detected and converted to a linear DC electrical signal by Setra’s unique electronic circuit. The micro-tig welded tension sensor allows up to 10 PSI overpressure range dependent with no damage to the unit.In addition, the sensor parts have thermally matched coeffi cients, which promote improved temperature performance and excellent long-term stability.

Unidirectional Pressure Bidirectional Pressure:
  • 0 to 0.25 in. WC 0 to ±0.1 in. WC
  • 0 to 0.5 in. WC 0 to ±0.25 in. WC
  • 0 to 1 in. WC 0 to ±0.5 in. WC
  • 0 to 2.5 in. WC 0 to ±1 in. WC
  • 0 to 5 in. WC 0 to ±2.5 in. WC
  • 0 to 10 in. WC 0 to ±5 in. WC
  • 0 to 25 in. WC 0 to ±10 in. WC
  • 0 to 50 in. WC 0 to ±25 in. WC
  • 0 to 100 in. WC 0 to ±50 in. WC
  • 0 to 25 Pa ±25 Pa
  • 0 to 50 Pa ±50 Pa
  • 0 to 100 Pa ±100 Pa
  • 0 to 250 Pa ±250 Pa
  • 0 to 500 Pa ±500 Pa
  • 0 to 1000 Pa ±1000 Pa

Applications:
  • Heating, Ventilating and
  • Air Conditioning (HVAC)
  • Energy Management Systems
  • Variable Air Volume and Fan Control (VAV)
  • Environmental Pollution Control
  • Static Duct and Clean Room Pressures
  • Oven Pressurization and
  • Furnace Draft Controls
 

Setra Model 265 Differential Pressure Transducer Range 0- 1000 Pac

 
 
Transducer TypePressure Transducer
BrandSetra
Voltage9 to 30VDC
Size8.0 x 4.8 x 4.2 cm
Mounting Type2,#10 screws
Pressure Range0- 1000 PAC

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year

Features:
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring

More Information:
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0-1000 PA 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 100 Pac

 
 
Transducer TypePressure Transducer
BrandSetra
Usage/ApplicationHeating Ventilating and Air Conditioning
Size3.16 Inch w x 1.89 Inch h x 1.64 Inch d
Mounting Type2,10 screws
Pressure Range0- 100 PAC
Supply Media24 VDC or 24 VAC


Supply Voltage:

  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring


More Information:

  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 100 PAC) 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA

Setra Model 265 Differential Pressure Transducer Range 0- 100 Inch

 
 
Transducer TypePressure Transducer
BrandSetra
Usage/ApplicationEnergy management systems
Output Voltage9 to 30VDC
Size3.16 Inch w x 1.89 Inch h x 1.64 Inch d
Mounting Type2,10 screws
Weight0.09 Kg

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring

More Information:
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 100 INCH 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 500 Pac

 
 
Transducer TypePressure Transducer
BrandSetra
Power24 VDC or 24 VAC
Usage/ApplicationHeating Ventilating and Air Conditioning
Size3.16 Inch w x 1.89 Inch h x 1.64 Inch d
Mounting Type2,10 screws
Energy Management SystemsVariable Air Volume and Fan Control
Environmental Pollution ControlStatic Duct and Clean Room Pressures

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 500 PAC) 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 250 Pac

 
 
Transducer TypePressure Transducer
BrandSetra
Power24 VDC or 24 VAC
Usage/ApplicationHeating Ventilating and Air Conditioning
Size3.16 Inch w x 1.89 Inch h x 1.64 Inch d
Mounting Type2,10 screws
Energy Management SystemsVariable Air Volume and Fan Control
Environmental Pollution ControlStatic Duct and Clean Room Pressures

Supply Voltage:
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 250 PAC) 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Setra Model 265 Differential Pressure Transducer Range 0- 0.25 Inch

 
 
Transducer TypePressure Transducer
BrandSetra
Usage/ApplicationVariable Air Volume and Fan Control
Size3.16 Inch w x 1.89 Inch h x 1.64 Inch d,8.0 x 4.8 x 4.2 cm
Mounting Type2 and 10 screws

Supply Voltage
  • Current output -9 to 30VDC @ 20 mA
  • Voltage Output – 0-5(10)v output 9(12) to 30VAC @ 0.6 VA; 0-5(10)v output 9(12) to 30V @ 25 mA
  • Accuracy – ± 1% Full scale, Opt .4% and .25%
  • Signal Output – 0-5V @ 5K???, 4-20mA @ 750??? (loop powered)
  • Sensor Type – Capacitive
  • Adjustments – (Z/S) Zero & Span trim POTs
  • Normal Measurement Range – (0 to 100″WC) or±(0.1 to 50″WC)
  • Overpressure – (Burst) ±10 psid (68.95 kPa)
  • Max Operating Pressure – (Proof) -50″WC to +100″WC
  • Operating Temperature – 0 to 150??? (-18 to 65???)
  • Operating Humidity – 10 to 95% Non-condensing
  • Wetted Parts – Stainless steel
  • Media Compatibility – Inert dry air
  • Process Connection – 3/16″OD plastic, for 1/4″ OD tubing
  • Wiring Exposed terminals – 2-(4-20mA), 3-(Volts)
  • Mounting – 2 , #10 screws
  • Enclosure Rating – NEMA1 equivalent, plastic UL94-V-0
  • Dimensions – 3.16″ w x 1.89″ h x 1.64″d, (8.0 x 4.8 x 4.2 cm)
  • Weight – 0.19 lb (0.09 Kg)
  • Approvals – CE
  • Warranty – 1 year
  • 1% accuracy improves variable air volume
  • Optional accuracies 0.4% or 0.25% FS
  • 24 VDC or 24 VAC excitation
  • Signal level 0-5 VDC, 0-10 VDC or 2-Wire 4-20 mA
  • UL94-V-), rated for Plenums
  • Fully protected against reverse wiring
  • Family Description – The Setra Model 265 Differential Pressure Transducer Provides Superior Positive and Negative Pressure Sensing Required For High Efficiency, Air-Control Systems. The Model 265 is a ±1.0% Full Scale Accuracy unit (±0.4%, ±0.25% FS Optional) With an Available Snap-on Conduit Enclosure Molded From High Impact Lexan®.
  • Enviro Tech Description – DP TRAN 0- 0.25 INCH 24 VDC/0-5VDC +/-1% FS W/ CERT
  • Manufacturer – SETRA USA
 

Dwyer USA Mark II Plastic Manometer Wholesaler

Mark II Model 40-1-AV Dwyer Manometer Range 0-1.1 Inches w.c

 
 
MaterialMolded Plastic
Accuracy+-3% FS
Model Name/NumberMARK II MODEL 40-1-AV MANOMETER
BrandDwyer USA
Scale LengthApprox. 8-1/4″ (21 cm)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Weight1.04 lb (472 g)/1.23 lb (558 g)


Mark II Model 40-1-AV Dwyer Manometer Range 0-1.1 Inches w.c
Dwyer Mark II Series Molded Manometers are of the inclined and inclined-vertical types. The Model 40 inclined gage provides linear calibration and excellent resolution throughout its range. Also, it is ideally suited for air velocity and air filter gage applications. Capable of pressure measurements above and below atmospheric as well as differential pressure measurements.

Construction:

Mark II Manometers are economically priced, compact and available in both stationary and portable configurations. The portable stand is a standard feature on Model 40. Construction is simple with virtually indestructible molded white styrene-acrylonitrile housing, indicating tube and fluid wells, molded ABS knobs and zero adjust plunger, shock mounted glass level vial and leak proof “O” ring seals. Greater protection is provided by float operated overflow traps in the Model 40. Scales are lithograph printed on aluminum and epoxy coated.

Installation:

Mark II Manometers can be mounted on any vertical surface with the two mounting screws provided. A built-in spirit level simplifies leveling before mounting screws are tightened. Simply fill the reservoir, adjust fluid level to zero, connect the tubing, and the gage is ready for operation.

Accessories:
Included with each Mark II Manometer are two tubing connectors for 1/8″ pipe or sheet metal ducts, two mounting screws, 3/4 ounce bottle of indicating fluid, red and green pointer flags and complete instructions. The Model 40 contains two 4-1/2 foot lengths of clear plastic tubing, a plastic swing-out stand and leveling screw for portable operation. It also features convenient rapid shutoff pressure connections and integral overpressure safety traps.

Below are other pressure ranges available for Series Mark II Manometer:

ModelRangeFluid Used
Mark II 40-1.1-0-1.0 in w.c.Red oil, .826 s.g.
Mark II 40-25mm0-26 mm w.cRed oil, .826 s.g.
Mark II 40-250PA10-0-250 PaRed oil, .826 s.g.
Mark II 41-2.2-0-2.4 in w.c.Blue oil, 1.91 s.g.
Mark II 41-60mm0-60 mm w.c.Blue oil, 1.91 s.g.
Mark II 41-600PA20-0-600 PaBlue oil, 1.91 s.g.
Mark II 40-1-AV*0-1.1 in w.c.
& 0-4200 fpm
Red oil, .826 s.g.
Mark II 40-250PA-AV*0-260 Pa
& 0-21 mps
Red oil, .826 s.g.
Mark II 41-2-AV*0-2.5 in wc.
& 0-6300 fpm
Blue oil, 1.91 s.g.

Mark II Model 40-1 Dwyer Manometer Range .1-0-1.0 Inches W.C

 
 
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationAir Filter Gage
BrandDwyer
Model Name/NumberMARK II MODEL 40-1
Scale LengthApprox. 8-1/4″ (21 cm)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Weight1.04 lb (472 g)/1.23 lb (558 g)


Mark II Model 40-1 Dwyer Manometer Range .1-0-1.0 Inches w.c Dwyer Mark II Series Molded Manometers are of the inclined and inclined-vertical types. The Model 40 inclined gage provides linear calibration and excellent resolution throughout its range. Also, it is ideally suited for Air Velocity and Air Filter Gage Applications. Capable of pressure measurements above and below atmospheric as well as Differential Pressure Measurements.

Construction:

  • Mark II Manometers are economically priced, compact and available in both stationary and portable configurations. The portable stand is a standard feature on Model 40. Construction is simple with virtually indestructible molded white styrene-acrylonitrile housing, indicating tube and fluid wells, molded ABS knobs and zero adjust plunger, shock mounted glass level vial and leak proof “O” ring seals. Greater protection is provided by float operated overflow traps in the Model 40. Scales are lithograph printed on aluminum and epoxy coated.


Installation:

  • Mark II Manometers can be mounted on any vertical surface with the two mounting screws provided. A built-in spirit level simplifies leveling before mounting screws are tightened. Simply fill the reservoir, adjust fluid level to zero, connect the tubing, and the gage is ready for operation.


Accessories:

  • Included with each
  • Mark II Manometer
  • are two tubing connectors for 1/8″ pipe or sheet metal ducts, two mounting screws, 3/4 ounce bottle of indicating fluid, red and green pointer flags and complete instructions. The Model 40 contains two 4-1/2 foot lengths of clear plastic tubing, a plastic swing-out stand and leveling screw for portable operation. It also features convenient rapid shutoff pressure connections and integral overpressure safety traps.


Below are other pressure ranges available for Series Mark II Manometer:

ModelRangeFluid Used
Mark II 40-1.1-0-1.0 in w.c.Red oil, .826 s.g.
Mark II 40-25mm0-26 mm w.cRed oil, .826 s.g.
Mark II 40-250PA10-0-250 PaRed oil, .826 s.g.
Mark II 41-2.2-0-2.4 in w.c.Blue oil, 1.91 s.g.
Mark II 41-60mm0-60 mm w.c.Blue oil, 1.91 s.g.
Mark II 41-600PA20-0-600 PaBlue oil, 1.91 s.g.
Mark II 40-1-AV*0-1.1 in w.c.
& 0-4200 fpm
Red oil, .826 s.g.
Mark II 40-250PA-AV*0-260 Pa
& 0-21 mps
Red oil, .826 s.g.
Mark II 41-2-AV*0-2.5 in wc. 
& 0-6300 fpm
Blue oil, 1.91 s.g.

Mark II Model 28 Dwyer Manometer Range 0-10,500 FPM

 
 
Minimum Order Quantity1 Number
Model Name/NumberMARK II MODEL 28
Usage/ApplicationLaboratory
Accuracy+-3% FS
Weight1.04 lb (472 g)/1.23 lb (558 g)
MaterialMolded Plastic
BrandDwyer
Scale LengthApprox. 8-1/4″ (21 cm
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)


Mark II Model 28 Dwyer Manometer Range 0-10,500 fpm Dwyer Mark II Series Molded Manometers are of the inclined and inclined-vertical types. The curved inclined-vertical tube of the Model 25 gage provides higher ranges with more easily read increments at low readings. The Model 25 is excellent for general purpose work. Capable of pressure measurements above and below atmospheric as well as differential pressure measurements.

Construction:

  • Mark II Manometers are economically priced, compact and available in both stationary and portable configurations, optional A-612 stand for Model 25. Construction is simple with virtually indestructible molded white styrene-acrylonitrile housing, indicating tube and fluid wells, molded ABS knobs and zero adjust plunger, shock mounted glass level vial and leak proof “O” ring seals. Moderate overpressures are accommodated by an overflow tank. Scales are lithograph printed on aluminum and epoxy coated.


Installation:

  • Mark II Manometers can be mounted on any vertical surface with the two mounting screws provided. A built-in spirit level simplifies leveling before mounting screws are tightened. Simply fill the reservoir, adjust fluid level to zero, connect the tubing, and the gage is ready for operation.


Accessories:

  • Included with each Mark II Manometer are two tubing connectors for 1/8″ pipe or sheet metal ducts, two mounting screws, 3/4 ounce bottle of indicating fluid, red and green pointer flags and complete instructions. The Model 25 also includes 8 feet of flexible double column plastic tubing. Portable operation is made possible by the use of the optional A-612 portable stand. A short piece of tubing can be slipped over the pressure connections to contain the gage oil in transit.


Below are other pressure ranges available for Series Mark II Manometer:

ModelRangeFluid Used
Mark II 250-3 in w.c.Red oil, .826 s.g.
Mark II 260-7 in w.c.Blue oil, 1.91 s.g.
Mark II 27*0-7000 fpmRed oil, .826 s.g.
Mark II 28*0-10,500 fpmBlue oil, 1.91 s.g.
Mark II MM-800-80 mm w.c.Red oil, .826 s.g.
Mark II MM-1800-180 mm w.c.Blue oil, 1.91 s.g.
Mark II M-700PA10-0-700 PaRed oil, .826 s.g.

Mark II Model 27 Dwyer Manometer Range 0-7000 FPM

 
 
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationAir Filter Gage
BrandDwyer
Model Name/NumberMARK II MODEL 27
Weight1.04 lb (472 g)/1.23 lb (558 g)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Scale LengthApprox. 8-1/4″ (21 cm).


Mark II Model 27 Dwyer Manometer Range 0-7000 fpm Dwyer Mark II Series Molded Manometers are of the inclined and inclined-vertical types. The curved inclined-vertical tube of the Model 25 gage provides higher ranges with more easily read increments at low readings. The Model 25 is excellent for general purpose work. Capable of pressure measurements above and below atmospheric as well as differential pressure measurements.

Construction:

  • Mark II Manometers are economically priced, compact and available in both stationary and portable configurations, optional A-612 stand for Model 25. Construction is simple with virtually indestructible molded white styrene-acrylonitrile housing, indicating tube and fluid wells, molded ABS knobs and zero adjust plunger, shock mounted glass level vial and leak proof “O” ring seals. Moderate overpressures are accommodated by an overflow tank. Scales are lithograph printed on aluminum and epoxy coated.


Installation

  • Mark II Manometers can be mounted on any vertical surface with the two mounting screws provided. A built-in spirit level simplifies leveling before mounting screws are tightened. Simply fill the reservoir, adjust fluid level to zero, connect the tubing, and the gage is ready for operation.


Accessories

  • Included with each Mark II Manometer are two tubing connectors for 1/8″ pipe or sheet metal ducts, two mounting screws, 3/4 ounce bottle of indicating fluid, red and green pointer flags and complete instructions. The Model 25 also includes 8 feet of flexible double column plastic tubing. Portable operation is made possible by the use of the optional A-612 portable stand. A short piece of tubing can be slipped over the pressure connections to contain the gage oil in transit.


Below are other pressure ranges available for Series Mark II Manometer:

ModelRangeFluid Used
Mark II 250-3 in w.c.Red oil, .826 s.g.
Mark II 260-7 in w.c.Blue oil, 1.91 s.g.
Mark II 27*0-7000 fpmRed oil, .826 s.g.
Mark II 28*0-10,500 fpmBlue oil, 1.91 s.g.
Mark II MM-800-80 mm w.c.Red oil, .826 s.g.
Mark II MM-1800-180 mm w.c.Blue oil, 1.91 s.g.
Mark II M-700PA10-0-700 PaRed oil, .826 s.g.

Mark II Model 26 Dwyer Manometer Range 0-7 Inches WC

 
 
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationAir Velocity Measurement
BrandDwyer
Model Name/NumberMARK II MODEL 26
Weight1.04 lb (472 g)/1.23 lb (558 g)
Scale LengthApprox. 8-1/4″ (21 cm)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)


Mark II Model 26 Dwyer Manometer Range 0-7 Inches WC Dwyer Mark II series molded manometers are of the inclined and inclined-vertical types. The curved inclined-vertical tube of the Model 25 gage provides higher ranges with more easily read increments at low readings. The Model 25 is excellent for general purpose work. Capable of pressure measurements above and below atmospheric as well as differential pressure measurements.

Construction

  • Mark II manometers
  • are economically priced, compact and available in both stationary and portable configurations, optional A-612 stand for Model 25. Construction is simple with virtually indestructible molded white styrene-acrylonitrile housing, indicating tube and fluid wells, molded ABS knobs and zero adjust plunger, shock mounted glass level vial and leak proof “O” ring seals. Moderate overpressures are accommodated by an overflow tank. Scales are lithograph printed on aluminum and epoxy coated.


Installation:

  • Mark II manometers can be mounted on any vertical surface with the two mounting screws provided. A built-in spirit level simplifies leveling before mounting screws are tightened. Simply fill the reservoir, adjust fluid level to zero, connect the tubing, and the gage is ready for operation.


Accessories:

  • Included with each Mark II manometer are two tubing connectors for 1/8″ pipe or sheet metal ducts, two mounting screws, 3/4 ounce bottle of indicating fluid, red and green pointer flags and complete instructions. The Model 25 also includes 8 feet of flexible double column plastic tubing. Portable operation is made possible by the use of the optional A-612 portable stand. A short piece of tubing can be slipped over the pressure connections to contain the gage oil in transit.


Below Are Other Pressure Ranges Available For Series Mark II Manometer:

ModelRangeFluid Used
Mark II 250-3 in w.c.Red oil, .826 s.g.
Mark II 260-7 in w.c.Blue oil, 1.91 s.g.
Mark II 27*0-7000 fpmRed oil, .826 s.g.
Mark II 28*0-10,500 fpmBlue oil, 1.91 s.g.
Mark II MM-800-80 mm w.c.Red oil, .826 s.g.
Mark II MM-1800-180 mm w.c.Blue oil, 1.91 s.g.
Mark II M-700PA10-0-700 PaRed oil, .826 s.g.

Mark II Model 25 Dwyer Manometer Range 0-3 Inches WC

 
 
MaterialMolded Plastic
Usage/ApplicationAir Velocity Measurement
Accuracy+-3% FS
Model Name/NumberMARK II 25 SERIES MARK II
BrandDwyer USA
Weight1.04 lb (472 g)/1.23 lb (558 g)
SizeApprox 8-1/4 INCH 21 cm
I Deal InNew Only
Scale LengthApprox. 8-1/4″ (21 cm)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)


Mark II Model 25 Dwyer Manometer Range 0-3 Inches WC Dwyer Mark II Series Molded Manometers are of the inclined and inclined-Vertical Types. The Curved Inclined-Vertical Tube of the Model 25 Gage provides higher ranges with more easily read increments at low readings. The Model 25 is excellent for general purpose work. Capable of pressure measurements above and below atmospheric as well as Differential Pressure Measurements.

Construction:

  • Mark II Manometers are economically priced, compact and available in both stationary and portable configurations, optional A-612 stand for Model 25. Construction is simple with virtually indestructible molded white styrene-acrylonitrile housing, indicating tube and fluid wells, molded ABS knobs and zero adjust plunger, shock mounted glass level vial and leak proof “O” ring seals. Moderate overpressures are accommodated by an overflow tank. Scales are lithograph printed on aluminum and epoxy coated.


Installation:

  • Mark II Manometers can be mounted on any vertical surface with the two mounting screws provided. A built-in spirit level simplifies leveling before mounting screws are tightened. Simply fill the reservoir, adjust fluid level to zero, connect the tubing, and the gage is ready for operation.


Accessories:

  • Included with each Mark II Manometer are two tubing connectors for 1/8″ pipe or sheet metal ducts, two mounting screws, 3/4 ounce bottle of indicating fluid, red and green pointer flags and complete instructions. The Model 25 also includes 8 feet of flexible double column plastic tubing. Portable operation is made possible by the use of the optional A-612 portable stand. A short piece of tubing can be slipped over the pressure connections to contain the gage oil in transit.


Below Are Other Pressure Ranges Available For Series Mark II Manometer:

ModelRangeFluid Used
Mark II 250-3 in w.c.Red oil, .826 s.g.
Mark II 260-7 in w.c.Blue oil, 1.91 s.g.
Mark II 27*0-7000 fpmRed oil, .826 s.g.
Mark II 28*0-10,500 fpmBlue oil, 1.91 s.g.
Mark II MM-800-80 mm w.c.Red oil, .826 s.g.
Mark II MM-1800-180 mm w.c.Blue oil, 1.91 s.g.
Mark II M-700PA10-0-700 PaRed oil, .826 s.g.

Mark II Dwyer Molded Plastic Manometer

 
 
Minimum Order Quantity1 Number
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationPaint Booths
BrandDwyer
Weight1.04 lb (472 g)/1.23 lb (558 g)
SizeApprox 8-1/4 INCH 21 cm
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Scale LengthApprox. 8-1/4″ (21 cm)


Mark II Dwyer Molded Plastic Manometer Series Mark Iimolded Manometers are of the inclined and inclined-vertical types. The curved inclined-vertical tube of the Model 25 gage provides higher ranges with more easily read increments at low readings. The Model 25 is excellent for general purpose work. The Model 40 inclined gage provides linear calibration and excellent resolution throughout its range. The Model 40 is ideally suited for air velocity and Air Filter Gage applications. Both Gage types are capable of pressure measurements above and below atmospheric as well as differential pressure measurements. Included with each Mark II Manometer are two tubing connectors for 1/8″ pipe or sheet metal ducts, two mounting screws, 1 ounce bottle of indicating fluid, red and green pointer flags and complete instructions. The Model 25 also includes 8′ of flexible double column plastic tubing. Portable operation of the Model 25 is made possible by the use of the optional A-612 portable stand. A short piece of tubing can be slipped over the Model 25 pressure connections to contain the gage fluid in transit. The Model 40 contains two 4-1/2′ lengths of clear plastic tubing, a plastic swing-out stand and leveling screw for portable operation. It also features convenient rapid shutoff pressure connections and integral overpressure safety traps. Click here, if you require a Safety Data Sheet for the Blue Gage Fluid or the Red Gage Fluid.

Product Applications:

  • Paint Booths
  • Air Velocity Measurement
  • Air Filter Gage


Models & Ordering:

ModelDescription
MARK II 25Molded Plastic Manometer, Range 0-3″ w.c., Red Oil, .826 sp. gr.
MARK II 26Molded Plastic Manometer,Rrange 0-7″ w.c., Blue Oil, 1.91 sp. gr.
MARK II 27Molded Plastic Manometer, Range 0-7000 fpm, Red Oil, .826 sp. gr., Requires Pitot Tube *Sold Separately.
MARK II 28Molded Plastic Manometer, Range 0-10,500 fpm, Blue Oil, 1.91 sp. gr., Requires Pitot Tube *Sold Separately.
MARK II 40-1Molded Plastic Manometer, Range .1-0-1.0″ w.c., Red Oil, .826 sp. gr.
MARK II 40-1-AVMolded Plastic Manometer, Range 0-1.1″ w.c. & 0-4200 FPM, Red Oil, .826 sp. gr., Requires Pitot Tube Sold Separately.
MARK II 40-250PAMolded Plastic Manometer, Range 10-0-250 Pa, Red Oil, .826 sp. gr.
MARK II 40-250PA-AVMolded Plastic Manometer, Range 0-260 Pa & 0-21 MPS, Red Oil, .826 sp. gr., Requires Pitot Tube Sold Separately.
MARK II 40-25MMMolded Plastic Manometer, Range 0-26 mm w.c., Red Oil, .826 sp. gr.
MARK II 41-2Molded Plastic Manometer, Range .2-0-2.4″ w.c., Blue Oil, 1.91 sp. gr.
MARK II 41-2-AVMolded Plastic Manometer, Range 0-2.5″ w.c. & 0-6300 FPM, Blue Oil, 1.91 sp. gr., Requires Pitot Tube Sold Separately.
MARK II 41-600PAMolded Plastic Manometer, Range 20-0-600 Pa, Blue Oil, 1.91 sp. gr.
MARK II 41-60MMMolded Plastic Manometer, Range 0-60 MM W.C., Blue Oil, 1.91 sp. gr.
MARK II M-700PAMolded Plastic Manometer, Range 10-0-700 Pa, Red Oil, .826 sp. gr.
MARK II MM-180Molded Plastic Manometer, Range 0-180 MM W.C., Blue Oil, 1.91 sp. gr.
MARK II MM-80Molded Plastic Manometer, Range 0-80 MM W.C., Red Oil, .826 sp. gr.

Mark II Model 40-250PA Dwyer Manometer Range 10-0-250 Pa

 
 
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationPaint Booths
BrandDwyer
Model Name/NumberMARK II MODEL 40-250PA
Weight1.04 lb (472 g)/1.23 lb (558 g)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Scale LengthApprox. 8-1/4″ (21 cm)


Mark II Model 40-250PA Dwyer Manometer Range 10-0-250 Pa Dwyer Mark II Series Molded Manometers are of the inclined and inclined-vertical types. The Model 40 inclined gage provides linear calibration and excellent resolution throughout its range. Also, it is ideally suited for air velocity and air filter gage applications. Capable of pressure measurements above and below atmospheric as well as differential pressure measurements.

Construction

  • Mark II Manometers are economically priced, compact and available in both stationary and portable configurations. The portable stand is a standard feature on Model 40. Construction is simple with virtually indestructible molded white styrene-acrylonitrile housing, indicating tube and fluid wells, molded ABS knobs and zero adjust plunger, shock mounted glass level vial and leak proof “O” ring seals. Greater protection is provided by float operated overflow traps in the Model 40. Scales are lithograph printed on aluminum and epoxy coated.


Installation:

  • Mark II Manometers can be mounted on any vertical surface with the two mounting screws provided. A built-in spirit level simplifies leveling before mounting screws are tightened. Simply fill the reservoir, adjust fluid level to zero, connect the tubing, and the gage is ready for operation.


Accessories

  • Included with each
  • Mark II Manometer are two tubing connectors for 1/8″ pipe or sheet metal ducts, two mounting screws, 3/4 ounce bottle of indicating fluid, red and green pointer flags and complete instructions. The Model 40 contains two 4-1/2 foot lengths of clear plastic tubing, a plastic swing-out stand and leveling screw for portable operation. It also features convenient rapid shutoff pressure connections and integral overpressure safety traps.


Below are other pressure ranges available for Series Mark II Manometer:

ModelRangeFluid Used
Mark II 40-1.1-0-1.0 in w.c.Red oil, .826 s.g.
Mark II 40-25mm0-26 mm w.cRed oil, .826 s.g.
Mark II 40-250PA10-0-250 PaRed oil, .826 s.g.
Mark II 41-2.2-0-2.4 in w.c.Blue oil, 1.91 s.g.
Mark II 41-60mm0-60 mm w.c.Blue oil, 1.91 s.g.
Mark II 41-600PA20-0-600 PaBlue oil, 1.91 s.g.
Mark II 40-1-AV*0-1.1 in w.c.
& 0-4200 fpm
Red oil, .826 s.g.
Mark II 40-250PA-AV*0-260 Pa
& 0-21 mps
Red oil, .826 s.g.
Mark II 41-2-AV*0-2.5 in wc. 
& 0-6300 fpm
Blue oil, 1.91 s.g.

Mark II Model 40-250PA-AV Dwyer Manometer Range 0-250 Pa,0-21 mps

 
 
Minimum Order Quantity1 Number
MaterialMolded Plastic
Accuracy+-3% FS
Model Name/NumberMARK II MODEL 40-250PA-AV
BrandDwyer USA
Weight1.04 lb (472 g)/1.23 lb (558 g)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Scale LengthApprox. 8-1/4″ (21 cm)

Mark II Model 40-250PA-AV Dwyer Manometer Range 0-250 Pa,0-21 mps 
Dwyer A-489 SS Straight Static Pressure Tip With Flange, 4″ (101 MM) Insertion Depth

Key Features:
  • Rapid Shutoff Pressure Connections and Integral Overpressure Safety Traps
  • Requires Pitot Tube, Not Included

Applications:
  • Air Velocity
  • Air Filter Guge

Other Details:
  • The Dwyer MARKII40250PAAV Molded Plastic Inclined Manometer, 0-260 Pa, 0-21 mps, Red Gauge Fluid, Requires Pitot Tube Provides Linear Calibration and Excellent Resolution Throughout its Range. This model is capable of pressure measurements above and below atmospheric as well as differential pressure measurements. The MARK II 40-250PA-AV includes accessories to enable portable use of the unit.

Included:
  • 2 – Tubing connectors for 1/8 in. pipe or sheet metal ducts
  • 2 – Mounting screws
  • 2 – 4-1/2” lengths of clear plastic tubing
  • 1 – Plastic swing-out stand
  • 1 – Leveling screw
  • 1 – 1 ounce bottle of indicating fluid
  • 1 – Set of red and green pointer flags
  • 1 – User Manual
 

Mark II Model 40-25MM Dwyer Manometer Range 0-26 MM W.C

 
 
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationPaint Booths
BrandDwyer
Model Name/NumberMARK II MODEL 40-25MM
Weight1.04 lb (472 g)/1.23 lb (558 g)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)

Mark II Model 40-25MM  Dwyer Manometer Range 0-26 MM W.C Dwyer A-489 SS Straight Static Pressure Tip With Flange, 4″ (101 MM) Insertion Depth

Key Features:
  • Rapid Shutoff Pressure Connections and Integral Overpressure Safety Traps
  • Requires Pitot Tube, Not Included

Applications:
  • Air Velocity
  • Air Filter Guge

Other Details:

The Dwyer MARKII40255MM Molded Plastic Inclined Manometer, 0-26 mm w.c., Red Gauge Fluid Provides linear Calibration and Excellent Resolution Throughout its Range. This model is capable of pressure Measurements above and below Atmospheric as well as Differential Pressure Measurements. The MARK II 40-255MM includes Accessories to Enable Portable Use of The Unit

Included:
  • 2 – Tubing connectors for 1/8 in. Pipe or Sheet Metal Ducts
  • 2 – Mounting Screws
  • 2 – 4-1/2” lengths of clear plastic Tubing
  • 1 – Plastic Swing-Out Stand
  • 1 – Leveling Screw
  • 1 – 1 ounce bottle of indicating fluid
  • 1 – Set of red and green pointer flags
  • 1 – User Manual
 

Mark II Model 41-2 Dwyer Manometer Range .2-0-2.4 Inches

 
 
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationAir Velocity Measurement
Model Name/NumberMARK II MODEL 41-2
Weight1.04 lb (472 g)/1.23 lb (558 g)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Scale LengthApprox. 8-1/4″ (21 cm)

Mark II Model 41-2 Dwyer Manometer Range .2-0-2.4 Inches Dwyer A-489 SS Straight Static Pressure Tip With Flange, 4″ (101 MM) Insertion Depth

Key Features:
  • Rapid Shutoff Pressure Connections and Integral Overpressure Safety Traps
  • Requires Pitot Tube, Not Included

Applications:
  • Air Velocity
  • Air Filter Guge

Other Details:
  • The Dwyer MARKII412 Molded Plastic Inclined Manometer, .2-0-2.4 INCHES., Blue Gauge Fluid Provides linear Calibration and Excellent Resolution Throughout its Range. This model is capable of pressure Measurements above and below Atmospheric as well as Differential Pressure Measurements. The MARK II 412 includes Accessories to Enable Portable Use of The Unit

Included:
  • 2 – Tubing connectors for 1/8 in. Pipe or Sheet Metal Ducts
  • 2 – Mounting Screws
  • 2 – 4-1/2” lengths of clear plastic Tubing
  • 1 – Plastic Swing-Out Stand
  • 1 – Leveling Screw
  • 1 – 1 ounce bottle of indicating fluid
  • 1 – Set of red and green pointer flags
  • 1 – User Manual
 

Mark II Model 41-2-AV Dwyer Manometer 0-2.5 inch W.C

 
 
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationPaint Booths
BrandDwyer
Model Name/NumberMARK II MODEL 41-2-AV
Scale LengthApprox. 8-1/4″ (21 cm)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Weight1.04 lb (472 g)/1.23 lb (558 g)

Mark II Model 41-2-AV Dwyer Manometer 0-2.5 inch w.c The Dwyer Mark II Series provides linear calibration and excellent resolution throughout its range and is ideally suited for air velocity and air filter gage Applications.
 

Mark II Model 41-600PA Dwyer Manometer 20-0-600 Pa

 
 
Minimum Order Quantity1 Number
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationPaint Booths
BrandDwyer
Model Name/NumberMARK II MODEL 41-600PA
Weight1.04 lb (472 g)/1.23 lb (558 g)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Scale LengthApprox. 8-1/4″ (21 cm)


Mark II Model 41-600PA Dwyer Manometer 20-0-600 Pa

  • Dwyer MARK II 41-600PA Inclined Manometer (20-0-600 Pa) using Blue Gauge Fluid
  • Model: MARK II 41-600PA | Order No: 41-600PA


Designed to Give Fast, Accurate Indication of Differential Pressures. The Gage May be used as a Readout device when measuring flowing fluids, pressure drop across filters, liquid levels in storage tanks and many other applications involving pressure.

Dwyer 41-600pa Manometer, Air Filter Gauge, 0-1

  • There are no moving parts – no mechanical linkages – nothing to wear out, jam or deteriorate from vibration.
  • They never need calibration.
  • 2 psi max. Pressure.
  • The mirror polished inclined scale allows the operator to easily read minute differences in differential pressure across the filter accurately without parallax error.
  • Over pressure safety traps


Specifications:

  • For Architects and Engineers
  • An Air Filter Gage for measuring the resistance to Air Flow through the filters shall be installed, one for each bank of filters. The gage shall be of inclined tube Differential Type (equipped with vent valves for zeroing) shall be of solid acrylic plastic construction with built-in level vial, shall have an adjustable mirror-polished scale, shall be furnished complete with two 5-foot lengths 1/4″ tubing, two static pressure tips, mounting hardware, additional bottle of Red Gage oil and instructions.


What”s Included With The Dwyer MARK II 41-600PA

  • Dwyer MARK II 41-600PA Inclined Manometer (20-0-600 Pa) Using Blue Gauge Fluid



Mark II Model 41-60MM Dwyer Manometer 0-60 MM

 
 
Minimum Order Quantity1 Number
MaterialMolded Plastic
Accuracy+-3% FS
Usage/ApplicationPaint Booths
BrandDwyer
Model Name/NumberMARK II MODEL 41-60MM
Weight1.04 lb (472 g)/1.23 lb (558 g)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Scale LengthApprox. 8-1/4″ (21 cm).

Mark II Model 41-60MM Dwyer Manometer 0-60 MM Dwyer MARK II 41-60MM Molded Plastic Inclined Manometer, 0-60 mm w.c., Blue Gauge Fluid

Product Features:
  • Range: 0-60 mm w.c.
  • Blue Gauge Fluid
  • Accuracy: ±3% FS
  • Pressure Limits:15 psi (100 kPa)
  • Rapid Shutoff Pressure Connections and integral overpressure safety Traps

Applications:
  • Air Velocity
  • Air Filter Gauge

The Dwyer MARKII4160MM Molded Plastic Inclined Manometer, 0-60 mm w.c., Blue Gauge Fluid provides linear calibration and excellent resolution throughout its range. This model is capable of pressure measurements above and below atmospheric as well as differential pressure measurements. The MARK II 41-60MM includes accessories to enable portable use of the unit.
  • 2 – Tubing connectors for 1/8 in. pipe or sheet metal ducts
  • 2 – Mounting screws
  • 2 – 4-1/2” lengths of clear plastic tubing
  • 1 – Plastic swing-out stand
  • 1 – Leveling screw
  • 1 – 1 ounce bottle of indicating fluid
  • 1 – Set of red and green pointer flags
  • 1 – User Manual

Model -A-489 Dwyer A-489 SS Straight Static Pressure Tip with Flange, 4″ (101 mm) Insertion Depth
 

Mark II M – 700Pa Dwyer Manometer 10-0-700 Pa

 
 
Minimum Order Quantity1 Number
Measuring Range10-0-700 PA
Accuracy3%
MaterialMolded Plastic
Usage/ApplicationPaint Booths
Model Name/NumberMARK II M – 700PA
BrandDwyer
Weight250 g

Mark II M – 700Pa Dwyer Manometer 10-0-700 Pa
  • Dwyer MARK II M-700PA Inclined/Vertical Manometer (10-0-700Pa) Using Red Gauge Oil
  • Model: MARK II M-700PA

Construction – Mark II Manometers are Economically Priced, Compact and Available in Both Stationary and Portable Configurations. Construction is Simple with Virtually indestructible Molded white Styrene-Acrylonitrile Housing, indicating tube and fluid wells, Molded ABS Knobs and Zero adjust plunger, shock Mounted Glass level vial and Leak Proof “O” Ring Seals.

Description:
  • Dwyer MARK II M-700PA Molded Plastic Manometer, Range 10-0-700 Pa
  • The Dwyer Mark II M-700PA Molded Plastic Manometer has a Range of 10-0-700 Pa, Red Oil, .829 sp. gr.

Dwyer® Mark II Series Molded Manometers are of the inclined and inclined-Vertical Types. The curved inclined-vertical Tube of the Model 25 gage provides higher Ranges with more easily read increments at low readings. The Model 25 is excellent for general purpose work. The Model 40 inclined gage provides linear calibration and excellent resolution throughout its range. The Model 40 is ideally suited for Air Velocity and Air Filter gage Applications. Both Gage Types are Capable of Pressure Measurements above and below Atmospheric as well as Differential Pressure Measurements.

Included:
  • What”s included With the Dwyer MARK II M-700PA
  • Dwyer MARK II M-700PA Inclined/Vertical Manometer (10-0-700Pa) Using Red Gauge Oil
 

Mark II MM-180 Dwyer Manometer 0-180 MM W.C

 
 
Minimum Order Quantity1 Number
Accuracy+-3% FS
BrandDwyer
Model Name/NumberMARK II MM-180
Weight1.04 lb (472 g)/1.23 lb (558 g)
Temperature Limits140 deg F (60 deg C)/150 deg F (65 deg C)
Pressure Limits10 psi (70 kPa)/15 psi (100 kPa)
Scale LengthApprox. 8-1/4″ (21 cm)


Mark II MM-180 Dwyer Manometer 0-180 MM W.C

  • Dwyer Mark II MM-180 Inclined/Vertical Manometer (0-180mm w.c.) Using Blue Gauge Oil
  • Model: MARK II MM-180


Construction – Mark II Manometers are Economically Priced, Compact and Available in Both Stationary and Portable Configurations. Construction is Simple with Virtually indestructible Molded white Styrene-Acrylonitrile Housing, indicating tube and fluid wells, Molded ABS Knobs and Zero adjust plunger, shock Mounted Glass level vial and Leak Proof “O” Ring Seals.


Description:

  • Dwyer MARK II MM-180 Molded Plastic Manometer 0-180 mm w.c.
  • The Dwyer Mark II MM-180 Molded Plastic Manometer Has a Range of 0-180 mm w.c., Blue Oil, 1.91 sp. gr.

 

Dwyer® Mark II Series Molded Manometers are of the inclined and Inclined-Vertical Types. The curved inclined-vertical tube of the Model 25 gage provides higher ranges with more easily read increments at low readings. The Model 25 is excellent for general purpose work. The Model 40 inclined gage provides linear calibration and excellent resolution throughout its range. The Model 40 is ideally suited for Air Velocity and Air Filter Gage Applications. Both gage types are capable of pressure measurements above and below atmospheric as well as Differential Pressure Measurements.

Included:

  • What”s Included With The Dwyer MARK II MM-180
  • Dwyer Mark II MM-180 Inclined/Vertical Manometer (0-180mm w.c.) Using Blue Gauge Oil

Mark II MM-80 Dwyer Manometer 0-80 MM W.C

 
 
Minimum Order Quantity1 Piece
MaterialMolded Plastic
Accuracy3%
Usage/ApplicationPaint Booths
Pressure Range0-80 MM W.C
BrandDwyer
Model Name/NumberMARK II MM-80
Weight250 f

Mark II MM-80 Dwyer Manometer 0-80 MM W.C

Dwyer Mark II MM-80 Inclined/Vertical Manometer (0-80mm w.c.) using Red Gauge OilModel: MARK II MM-80
  • Dwyer Mark II MM-80 Inclined/Vertical Manometer (0-80mm w.c.) Using Red Gauge Oil
  • Model: MARK II MM-80

Construction – Mark II Manometers are Economically Priced, Compact and Available in Both Stationary and Portable Configurations. Construction is Simple With Virtually Indestructible Molded White Styrene-Acrylonitrile Housing, Indicating Tube and Fluid Wells, Molded ABS Knobs and Zero Adjust Plunger, Shock Mounted Glass level vial and Leak Proof “O” Ring Seals.

Description:
  • Dwyer MARK II MM-80 Molded Plastic Manometer, 0-80 mm w.c.
  • The Dwyer Mark II MM-80 Molded Plastic Manomater has a range of 0-80 mm w.c., red oit, .829 sp. gr.

Dwyer® Mark II Series Molded Manometers are of The Inclined and Inclined-Vertical Types. The curved inclined-vertical tube of the Model 25 Gage Provides Higher Ranges with More Easily Read increments at low readings. The Model 25 is excellent for General Purpose work. The Model 40 inclined Gage provides linear calibration and excellent resolution throughout its range. The Model 40 is ideally suited for Air Velocity and Air Filter Gage Applications. Both gage Types Are Capable of Pressure Measurements above and below atmospheric as well as Differential Pressure Measurements.

What”s included with the Dwyer MARK II MM-80
  • Dwyer Mark II MM-80 Inclined/Vertical Manometer (0-80mm w.c.) Using Red Gauge Oil