2000-60PA-ASF Dwyer Instruments | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2000-60PA-ASF Dwyer Instruments Select the Magnehelic gage for high accuracy–guaranteed within 2% of full scale–and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer’s simple, frictionless Magnehelic gage movement, it quickly indicates low air or non-corrosive gas pressures–either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It’s inexpensive, too. The Magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment
Overpressure Protection:
|
Series TDFS Thermal Dispersion Flow Switch | |||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Series TDFS Thermal Dispersion Flow Switch
The Series TDFS2 Thermal Dispersion Flow Switch is a thermal flow switch that indicates whether the flow rate is above or below a user set flow rate. The unit incorporates two LED status indicators providing visual switch indication. The set flow rate (setpoint) is field adjustable and the unit has both NO and NC NPN outputs. See Figure 1 on catalog page for output and LED actions on change of flow Product Applications:
Model – TDFS2-1-P-06 Thermal Dispersion Flow Switch, 316SS, 1/2″ NPT Process Connection, 6′ of Cable With Cable Gland. |
TDFS-1-P-06 Thermal Dispersion Flow Switch | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDFS-1-P-06 Thermal Dispersion Flow Switch
The Series TDFS2 Thermal Dispersion Flow Switch is a thermal flow switch that indicates whether the flow rate is above or below a user set flow rate. The unit incorporates two LED status indicators providing visual switch indication. The set flow rate (setpoint) is field adjustable and the unit has both NO and NC NPN outputs. See Figure 1 on catalog page for output and LED actions on change of flow Product Applications:
Model – TDFS2-1-P-06
|