Our Products

Elementor #1257


RHP-2D10 DWYER Humidity Temperature Transmitter

Rs 9,500 / Piece

BrandDWYER USA
Model Name/NumberRHP-2D10
Usage/ApplicationPharma

RHP-2D10 DWYER Humidity Temperature Transmitter
Overview
Dwyer Instruments
Humidity Sensors, RHP Series
Item# RHP-2D10 – Duct Mount Humid- Ity Transmitter Wtih 2% Sensor And 4-20 Ma Output
RHP Series Information
The Series RHP Temperature and Humidity Transmitter Combine the Voltage or Current Humidity Transmitter output with a passive Temperature Thermistor or RTD output. Featuring Polymer Capacitance Humidity Sensors, Models are available in 2%, 3% or 5% accuracies. Duct mounted transmitters are available with an optional two-line alpha numeric LCD Display.
Product Applications
Air EconomizersOutdoor Temperature and Relative Humidity ReferencePool Room Humidity Monitoring
Specifications
Item Number:  RHP-2D10Brand:Dwyer InstrumentsItem Category:HVAC SensorsSubcategory:Humidity SensorsSeries:RHPApplication:DuctInput:10~35 VDCOutput:4~20 mADisplay:NoneHumidity Range:0 to 100% RHTemperature Sensor:NoApprovals:CEH x W x D:4 in x 4.4 in x 11.75 inNet Weight:8.24 ozGross Weight:1 lb


Model 670 Fume Hood Monitor

Model 670 Fume Hood Monitor

The Model 670 Fume Hood Monitor continuously senses air flow through the face of the fume hood, ensuring safe levels of fresh air are exhausting potentially hazardous fumes eliminating operator exposure. The 670 provides a highly accurate hot wire sensor to detect very low flows common on fume hoods. This fume hood monitor provides several key features such as simplified calibration and mounting, LED safe and alarm status indicators, audible alarm with temporary or permanent horn silence, relay alarm output, sash alarm input and an input for night set-back. The Model 670 comes with everything required to quickly install the unit including a mounting bracket, 24″ of tubing for connecting to the inside of the hood wall and a 120 Volt AC power adapter.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Model 660 Air Velocity Monitor

Model 660 Air Velocity Monitor

Model 660 Air Velocity Monitors are a practical, affordable way to continuously monitor for safe air flows through laboratory fume hoods. They are typically installed in the fume hood side fascia and connected to the interior sidewall via 1-18″ flexible tubing. As the exhaust fan draws air through the device, a sensitive constant temperature thermistor measures flow and lights a green (normal), yellow (high) or red (low) LED. An audible alarm also warns of low flow and requires manual resetting. Mounting holes fit standard single gang electrical box.

 

  • Product Applications : Warns user if insufficient fume hood face velocity is encountered.



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Model 530 Air Flow Switch
BrandDWYER USA
Model NumberModel 530

Model 530 Air Flow Switch

The Model 530 air flow switch provides excellent sensitivity and reliability at a very reasonable price. Quality features include a rugged die cast body, stainless steel vane and SPDT snap switch. Unit is field adjustable from 400-1600 FPM. Mounting is fast and simple, with only two screws needed. Vane fits 6″ or larger ducts.

 

  • Product Applications : Low air flow condition duct alarm.



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023


Series AVFS Air Flow Switch
BrandDWYER USA
Model NumberSeries AVFS
Flow Media TypeLiquid, Gas, Steam

Series AVFS Air Flow Switch

The new Series AVFS Adjustable Air Flow Switch complements the Dwyer Instruments line of thermo-anemometer transmitters and handheld instruments. The AVFS is specifically designed to monitor air flow in ducts and provides a 3A contact output to indicate a change or loss of flow. Simply turn on the fan or air handling unit and adjust the set-point via the potentiometer to show normal status. Then alter a damper or decrease fan speed to activate the AVFS. The AVFS will signal a loss of flow and the N.O. SPST output will indicate the detected decrease. For ease of installation and system troubleshooting, the Series AVFS possesses a redgreen LED indication to provide local status if the air flow is above (green) or below (red) the set-point. The AVFS provides a ±5% set-point repeatability across a full scale range of 1-10 ms (197-1969 fpm) and includes a mounting bracket for quick duct mounting. The AVFS Series Adjustable Air Flow Switches come in a compact, rugged PBT enclosure that is rated NEMA 4X (IP65), making them ideal for any ventilation system installation or similar BAS application.

 

  • Product Applications : Fan monitoring,Damper feedback,Filter monitoring,Air handlers.



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023


Series AVU Air Velocity Transmitter

Series AVU Air Velocity Transmitter

The Dwyer Series AVU Air Velocity Transmitter is ideal for a wide range of HVAC measurement and control applications, particularly in complete building control and energy management systems. The Series AVU offers 5% accuracy at a surprisingly low cost, with six units covering ranges from 0-785 fpm to 0-3150 fpm, with either 4-20 mA or 0-10 VDC output.

The Series AVU Transmitter operates by measuring the heat loss from one of the two sensing elements in the air-stream, then calculating the air velocity. Units are virtually immune to drift due to the design of the sensing element, which makes the transmitter accurate over the whole air velocity range.

 

  • Product Applications : Supply and Exhaust Fan Tracking,Clean Room Systems,Medical Rooms



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

The Series AVU Transmitter operates by measuring the heat loss from one of the two sensing elements in the air-stream, then calculating the air velocity. Units are virtually immune to drift due to the design of the sensing element, which makes the transmitter accurate over the whole air velocity range.

Product Applications : Supply and Exhaust Fan Tracking,Clean Room Systems,Medical Rooms

Additional Information:

Pay Mode Terms: T/T (Bank Transfer)
Port of Dispatch: DELHI
Production Capacity: 8368801023


Series VTT Hot-Wire Air Velocity Transmitter

Series VTT Hot-Wire Air Velocity Transmitter

The Series VTT Hot-Wire Air Velocity and Temperature Transmitter provides a versatile unit for air velocity and temperature needs. The VTT offers five field-selectable ranges as well as operating in metric (ms, °C) or English (fpm, °F) units. The VTT can measure up to 30 ms (6000 fpm) and 50°C (122°F). The units are available with or without an LCD display which alternates between velocity and temperature. Series VTT can be ordered in duct mount or remote mount configurations with 4-20 mA or 0-10 V outputs. The VTT is a useful transmitter for many common HVAC applications.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series 641 Air Velocity Transmitter
Series 641Air Velocity Transmitter


Series 641 Air Velocity Transmitter

The new Series 641 Air Velocity Transmitter is the ideal instrument for monitoring air flow. This transmitter uses a heated mass flow sensor which allows for precise velocity measurements at various flow rates and temperatures. The 641’s 16 field selectable ranges provides it the versatility to be selected for several air flow applications. The optional LED produces a complete, low-cost solution for local indication of air flow.

 

  • Product Applications : Exhaust Stack Flow Monitoring,HVAC Air Velocity Measurements,Clean Room Fresh Air Supply Etc.



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Model 641B Air Velocity Transmitter
Model 641BRanges of 1.25 MPS to 10 MPS

Model 641B Air Velocity Transmitter
The Model 641B Air Velocity Transmitter uses a heated mass flow sensor technology. It has four user-selectable ranges from 250 FPM to 2000 FPM with four corresponding metric ranges of 1.25 MPS to 10 MPS. The 641 B provides an isolated 4-20 mA output proportional to the velocity.

The Model 641B’s steel sensor allows the unit to be used in dirty air environments. This rugged sensor is ideally suited for quick field cleaning from a simple cloth to a pulse of air from an air source. Proper sensor performance can be maintained in these polluted environments by easily removing dust and debris from the sensor which is problematic for Pitot tubes and other flow sensing transmitters.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series PAFS-1000 Averaging Flow Sensor
Series PAFS-1000models PAFS-1002 to PAFS-1005

Series PAFS-1000 Averaging Flow Sensor

The Series PAFS-1000 Averaging Flow Sensor is ideal for sensing differential pressure in the inlet section of variable air volume terminal units and fan terminal units. Units can also be used to sense differential pressure at other locations in the main or branch duct systems.

The “H” port senses total pressure and the “L” port senses static pressure. The difference between these signals is the differential, or velocity pressure. For models PAFS-1002 to PAFS-1005, up to four sensing points and lengths of 3-532″ to 9-2932″ (8.02 to 25.26 cm) to accommodate box size diameters of 4″ to 16″ (10.16 to 40.64 cm) are available. For models PAFS-1006 to PAFS -1011, up to 10 sensing points and lengths from 12-12″ to 23-2932″ (31.75 to 60.72 cm) are available to accommodate appropriately sized duct dimensions.

 

  • Applications : Zone control in HVAC systems



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series DAFM Duct Air Flow Measuring Probe
BrandDWYER USA
ModelSeries DAFM

Series DAFM Duct Air Flow Measuring Probe

The Model DAFM Duct Air Flow Measuring Probe uses evenly distributed total and static pressure measuring points to deliver an accurate measurement of flows in a duct. The Air Flow Measuring Probe can be completely installed from outside of the duct making it very easy to install. With its lightweight and durable construction in addition to its ease of installation, this product lends itself to being used in the HVAC industry. These air flow measuring probes may be ordered for either round or rectangular ducts. In order to ensure accurate measurements you must determine the number of probes needed for your size duct. If the duct is rectangular, then consult the chart to determine appropriate quantity of probes.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series Rhp-w Wall Mount Humidity Transmitter

Series RHP-W Wall Mount Humidity Transmitter
The Series RHP-W Wall Mount HumidityTemperatureDew Point Transmitter is the most versatile room transmitter on the market. The stylish housing is well vented to provide air flow across the sensor to improve measurement accuracy. An optional LCD display can be integral to the transmitter or a remote display can be ordered for building balancing or LEED® validation. The LCD display indicates the ambient temperature along with the humidity or dew point. The transmitter has internal dip switches to select the temperature engineering units and whether the transmitter outputs humidity or dew point.

The humidity and temperature sensors are field replaceable to reduce service cost and inventory. The humidity and the dew point are measured using a capacitive polymer sensor that completely recovers from 100% saturation. The humidity and dew point can have either a current or voltage output, while the optional temperature output can be a current, voltage, RTD or thermistor. For models with current or voltage for the temperature output, the temperature range is field selectable. For models with resistive thermistors or RTD outputs, please click here for temperature to resistance lookup tables.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series Rhp Temperature Transmitter

Series RHP Temperature Transmitter

The Series RHP Temperature and Humidity Transmitter combine the voltage or current humidity transmitter output with a passive temperature thermistor or RTD output. The polymer capacitance humidity sensor is not affected by condensation, fog, high humidity, or contaminants. The humidity sensors are available with 2% or 3% accuracies. Duct mounted transmitters are available with an optional two-line alpha numeric LCD display. The Series RHP is available with interchangeable filter options as well as replaceable sensors.

For models with resistive thermistors or RTD outputs, please click here for temperature to resistance lookup tables.

 

  • Application : For duct mount installations, the sintered filter option should be ordered for applications where the humidity transmitter is mounted in the supply air duct after the fan and cooling coils.



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series Rhrs Outside Air Humidity Radiation Shield

Series RHRS Outside Air Humidity Radiation Shield

The Series RHRS Radiation Shield protects outside air humidity transmitters from rain and radiated heat. With the curved shape and color of the plates, air flow is able to move across the sensor to keep radiated temperatures from rooftops and surrounding surfaces from affecting humidity readings. For ease of installation, the Series RHRS has integral pipe mounting hardware which can be removed for surface mounting applications. The brackets on the Series RHRS are specifically designed to be installed on the Dwyer Series RHP outside air humidity transmitters with sintered filters. The pipe mounting bracket fits 34″ to 1-12″ iron pipe.


Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Model 657C-1 Relative Humidity Transmitter

Model 657C-1 Relative Humidity Transmitter
The Model 657C-1 Transmitter features the same circuit design as the 657-1 providing two 4-20 mA channels to produce separate output signals for both relative humidity and temperature. However, this model is housed in a tough die cast aluminum protective conduit enclosure with gasketed cover. An internal terminal block is provided for electrical connections. The sensor employed in the 657C-1 features a state-of-the-art integrated polymer film humidity sensor and a thin-film platinum temperature sensor to assure high reliability and rock-solid stability over years of continuous service. Stainless steel probe measures 516″ x 9-110″ (0.8 x 23.1 cm) and can be easily mounted to most ductwork using either of two optional kits.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

HHT Hazardous Area Humidity Transmitter

HHT Hazardous Area Humidity Transmitter

The Series HHT Hazardous Area HumidityTemperature Transmitter takes accurate measurements in the harshest of environments. The transmitter is offered in explosion-proof and intrinsically-safe versions depending on the application’s requirements. The explosion-proof model is offered with 4 to 20 mA output for humidity only. The intrinsically-safe version is offered with 4 to 20 mA output for humidity and temperature. Both versions have an optional two line alphanumeric display to show the current humidity and temperature.

The Series HHT humiditytemperature transmitter is excellent for offshore HVAC applications, dust and grain applications. Intrinsically safe models require an intrinsically safe barrier.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Inclined Manometer
ModelDwyer Usa
BrandDwyer Usa

Inclined Manometer

Dwyer® Durablock® Series 250-AF Gages are precision machined 1″ thick solid acrylic plastic, virtually unbreakable and free of distortion. The fluid bore is precision drilled to ±.0002″ to assure life long accuracy. A glass spirit level is built into the body and encapsulated to prevent damage or tampering. The scale is mirror polished chrome plated brass to assure parallax free reading by alignment of the meniscus with its reflection. Safety traps are incorporated in the body to prevent loss of fluid due to pressure surges. Red and green signal flags indicate clearly when a filter change is necessary. Gages are suitable for use in ambient temperatures of -20 to 150°F. Connection fittings are positively sealed by “O” rings but easily removed for zeroing or addition of fluid. Furnished complete with instructions.

 

  • thick : 5/8″



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Thermal Dispersion Flow Switch

Thermal Dispersion Flow Switch

The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC operation and are not damaged by over-ranging flow velocities.

 

  • calibrated : 0.2 fps



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Model AAFS Adjustable Air Flow Paddle Switch
Model No.Model AAFS
BrandDwyer Usa


Model AAFS Adjustable Air Flow Paddle Switch

The Model AAFS-1 Adjustable Air Flow Switch is capable of detecting a wide range of air velocities with minimal user calibration. The adjustable screw changes the set point at which the SPDT snap switch engages. Quality features include a stainless steel vane, galvanized steel base, and ABS enclosure. The unit is field adjustable from 200 to 1800 FPM (1 to 9.2 msec).

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series 641RM Air Velocity Transmitter
ApplicationClean Room Fresh Air Supply,HVAC Air Velocity Measurements,Fan Supply and Exhaust Tracking,Ensure Po

Series 641RM Air Velocity Transmitter with Cable

The Series 641RM is the ideal instrument for monitoring air flow. This transmitter uses a heated mass flow sensor, which allows for precise velocity measurements at various flow rates and temperatures. The 641’s 16 field selectable ranges from 0-250 to 15,000 FPM (0-1.25 to 75 MPS) provide it the versatility to be selected for a multitude of applications. The units 6′ cable which connects the sensing probe with the electronic enclosure allows the enclosure to be mounted where it can be more easily accessed. Longer cable lengths are available fro ducts that are at very high elevations from the plant floor. The optional LED produces a complete, compact solution for local indication of air flow.

 

  • Product Applications : Clean Room Fresh Air Supply,HVAC Air Velocity Measurements,Fan Supply and Exhaust Tracking,Ensure Porper Lab Hood Exhaust Flow Rates



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series MAFS Metal Averaging Flow Sensor
Series MAFSapplications in the HVAC industry

Series MAFS Metal Averaging Flow Sensor
The Series MAFS is ideal for use with Dwyer Instruments, Inc. precision air velocity gages, transmitters and switches. The Series MAFS uses evenly distributed total and static pressure measuring points to deliver an accurate measurement of flows in a duct. The blade profile provides enhanced performance with minimal flow disruption in the air stream. The air flow measuring probe can be completely installed from the outside of round or circular ducts, making it very quick to install. With its lightweight and durable construction, in addition to its ease of installation, the MAFS flow sensor lends itself superbly to applications in the HVAC industry.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023
Series AFG Averaging Flow Grid
BrandDWYER USA

Series AFG Averaging Flow Grid

The Series AFG Flow Grid is an outstanding simple yet accurate cost effective alternative to other duct mounted pressure sensors. Once installed and connected to a suitable measuring instrument, the device will provide years of trouble free monitoring of both air and gas flow. Installing the AFG Flow Grid is quick and easy, the AFG is supplied in kit form to allow both workshop and on-site installation into a wide range of square and circular ducts up to approximately 60″.

The AFG Flow Grid is a fundamental pressure sensing device designed to transmit a continuous differential pressure signal. When this output is connected to a suitable measuring instrument (i.e., manometer, pressure transducer, etc.), it may be used to determine air velocity and volume flow rate.

How the AFG Flow Grid Works
The AFG Flow Grid consists of two tubes mounted diagonally across a square or rectangular duct, or diametrically across a round duct. The tubes are drilled with a series of equi-spaced holes.

 

  • Applications : To display differential pressure, velocity of volume flow using a micro manometer etc.



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023
Series FAFM Fan Inlet Air Flow Measuring Probe
BrandDWYER USA
ModelSeries FAFM
Series FAFM Fan Inlet Air Flow Measuring Probe
 

The Model FAFM Fan Inlet Air Flow Measuring Probes use evenly distributed total and static pressure measuring points to deliver an accurate measurement of flows in a fan inlet. The Air Flow Measuring Probes can be completely installed from outside of the fan making it ideal for when proper duct locations are unavailable. With its lightweight and durable construction in addition to its ease of installation, this product lends itself to being used in the HVAC industry.

There are two versions of the model FAFM fan inlet air flow probes to choose from depending on the depth of the fan inlet.

For fan inlets with depth less than 3-12″ (8.89 cm): Please order a fan inlet probe with an “S” suffix. This probe has a diameter of .375″ (.95 cm). It employs one total flow measuring tube and one static measuring tube. Each probe is covered with an extruded aluminum anodized coat. Each measuring tube has multiple sensing points.

For fan inlets with depth greater than 3-12″ (8.89 cm): Please order a fan inlet probe with a “D” suffix. This probe has a diameter of 3-12″ (8.89 cm). It employs extruded aluminum anodized coated probes with both total and static sensors on each tube.

Please Note: These are sold in sets of two. A set is necessary in order to ensure an accurate reading. No more than two air flow measurement probes will be needed to obtain an accurate reading.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

 

 
Series FLST Duct Mounted Airflow Measurement Station
BrandDWYER USA
ModelSeries FLST

Series FLST Duct Mounted Airflow Measurement Station

The Series FLST Airflow Measurement Station is easy to install — simply connect the tubing to the station fittings, then to a differential pressure manometer, gage, transmitter or switch. Single or multiple airflow elements are factory mounted and pre-piped in a casing designed for flanged connection to the duct work. Standard materials consist of a G90 galvanized casing and 6063-T5 anodized aluminum flow sensors, suitable for most HVAC applications.

The Series FLST utilizes an airflow averaging element in a head-type device, generating a differential (velocity) pressure signal similar to the orifice, venturi, and other had producing primary elements. Strategically located sensing ports continually sample the total and static pressures when inserted normal to flow.

Total pressure sensed by the upstream ports are continually averaged within the airflow element in an isolated chamber. The static sensing ports are averaged in a second isolation chamber. Multiple elements are joined together for connection to a differential measurement device (gage, transmitter, etc.) for flow measurement and indication purposes.

 

  • Applications : Sensing fan, blower, and air handler output,Determine duct flow rates in various zones in builiding



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023
Series STRA Duct Mounted Airflow Measurement Station
BrandDWYER USA
ModelSeries STRA

Series STRA Duct Mounted Airflow Measurement Station

The Series STRA Airflow Measurement Station is easy to install — simply connect the tubing to the station fittings, then to a differential pressure manometer, gage, transmitter or switch. Single or multiple airflow elements are factory mounted and pre-piped in a casing designed for flanged connection to the duct work. The Series STRA utilizes an airflow averaging element in a head-type device, generating a differential (velocity) pressure signal similar to the orifice, venturi, and other head producing primary elements. It has been developed with a honeycomb airflow straightening section for use in duct systems having highly turbulent conditions at the point of measurement. Strategically located sensing ports continually sample the total and static pressures when inserted normal to flow. Total pressures sensed by the upstream ports are continually averaged within the airflow element in an isolated chamber. The static sensing ports are averaged in a second isolation chamber. Multiple elements are joined together for connection to a differential measurement device (gage, transmitter, etc.) for flow measurement and indication purposes.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023
Series HS Humidity Switch
BrandDWYER USA
Model No.
Series HS

Series HS Humidity Switch

The microprocessor based Series HS Humidity Switch provides control for humidifying or dehumidifying. Relative humidity, output status, and error messaging can be viewed on the bright green LED. The switch features 9 user defined parameters including setpoint, hysteresis, control type, cycle time, and probe adjustment. Access to programming parameters can be locked for security purposes using the password protection feature. The Series HS includes a fitting clip for panel mounting, gasket, rear terminal cover, and instruction manual.

 

  • Product Applications Industrial Chillers,Environmental Chambers,Walk-ins and Freezers,Heat SealersBeer and Wine Chillers,Mug Frosters Etc.



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023
Series THC Temperature Switch
BrandDWYER USA
ModelSeries THC

Series THC Temperature Switch


Simultaneously measure and control temperature and humidity with the Series THC TemperatureHumidity Switch. The unit offers a 3-digit red display for temperature indication and a 3-digit green display indicating humidity. The Series THC is equipped with four independent relays, two for temperature control and two relays for humidity control.

The unit offers 61 programmable parameters for temperature and humidity control including set point, differential, directreverse acting, cycle time, alarm clock time, and decimal point adjustment. In the event of a probe error, the default operation of the relays can be set to open or close. The THC features error or alarm messaging and password protection.

The THC TemperatureHumidity Switch accepts up to two temperature probe inputs (sold separately) and a humidity sensor. A humidity sensor with 0-1V, 0-3V (sold separately), or 4-20 mA output can be used with the Series THC.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series RH-R Temperature Transmitter

Series RH-R Temperature Transmitter
The Series RH-R Humidity Transmitter is the ideal transmitter for those applications where space is limited. The compact sensor is protected by a removable filter. It can be mounted up to 16 feet away from the weatherproof base. The Series RH-R is ideal for environmental chambers, rubber bladder burst detection and air handler applications.


Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

657-1 Relative Temperature Transmitter

657-1 Relative Temperature Transmitter
The Model 657-1 Transmitter provides two 4-20 mA channels to produce separate output signals for both relative humidity and temperature. This inexpensive device delivers ±2% accuracy for humidity and ±3% for temperature measurements. The sensor employed in the 657-1 features a state-of-the-art integrated polymer film humidity sensor and a thin-film platinum temperature sensor to assure high reliability and rock-solid stability over years of continuous service. Stainless steel probe measures 516″ x 10″ (0.8 x 24.4 cm) and can be easily mounted to most ductwork using either of the two optional kits.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023
WHT Weather-Resistant Humidity Transmitter

The Compact Series WHT HumidityTemperature Transmitter is designed to withstand the elements. A removable sintered filter protects the polymer capacitance sensor from solid objects that may come in contact with the transmitter. The transmitter is available with 4 to 20 mA or 0 to 10 VDC output signals for both temperature and humidity. This transmitter is ideal for measuring outside air temperature and humidity levels for air handling economizer applications.

Space Mount Carbon Dioxide Transmitter
Display TypeAnalog, Digital


Space Mount Carbon Dioxide Transmitter

The Ventostat 8000 Series represents a full range of wall mount CO2 and temperature transmitters with display options plus active humidity and temperature outputs.

 

  • Features: : Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package,Etc.



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Series CDX Wall Mount Carbon Dioxide Transmitter

Series CDX Wall Mount Carbon Dioxide Transmitter

The Series CDX Carbon Dioxide Transmitter is a low cost and high performing CO2 sensor. This product will provide immediate energy savings by functioning in conjunction with building automation systems and allowing the user to effortlessly and effectively control fresh air into preferred areas. On-Demand ventilation using CO2 sensors prevents energy losses from over ventilation while maintaining indoor air quality. The potential for the greatest energy saving occurs in areas where occupancy alters over the duration of the day. The Series CDX Transmitters utilize the patented Automatic Background Calibration (ABC) Logic self-calibration system. ABC Logic virtually eliminates the need for manual calibration in applications where the indoor CO2 level drops to outside levels during unoccupied periods. If the transmitter is being used in an application where a building is continuously occupied 24 hours per day, then the user will permit that the ABC Logic feature be turned off.

 

  • Product Applications : On Demand Ventilation



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023
 

 

 

 

 
Model CDD Duct Mount Carbon Dioxide Transmitter
Display TypeAnalog, Digital
ModelDWYER USA

Model CDD Duct Mount Carbon Dioxide Transmitter

The Model CDD Duct Mount Carbon Dioxide Transmitter monitors the occupancy in a room by detecting the concentration of carbon dioxide in the return air duct. The non-dispersive infrared sensing technology automatically updates the calibration of the transmitter using a proprietary logic feature which limits the amount of error due to drift. The Model CDD can measure up to 2000 PPM in duct air flows less than 1500 FPM.

 

  • Product Applications : On demand room ventilation

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

Remote Reading Thermometer
BrandDWYER USA

Remote Reading Thermometer

The Series RRT3 Remote Reading Thermometer with Switch combines an easy to read 3-14″ dual scale dial thermometer and a SPDT relay. Color coordinated pointers display the current process temperature and set point. In order to change the set point, a front adjustment knob controls the red set point pointer. The design of the internal mechanical switch movement prevents the set point pointer from sticking to the process indicating pointer. A 10.5 ft (3.2 m) stainless steel flex hose capillary prevents kinking and leaking of the measuring fluid when bending the capillary. For quick installation, electrical connections can be made to male quick connects or to the finger-safe screw terminals. Thermometer includes a u-clamp mounting bracket for panel mounting.

 

  • dual scale 3-1/4″



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023
Digital Pressure Transmitter
Model Number/NameSeries DPT
BrandDWYER USA

digital pressure transmitter
The Series DPT Digital Pressure Transmitter with Switches combines a large, 14-segment LED display with two programmable solid state switches into one compact unit. A unique, 3-way rotating design allows the DPT to meet specific installation requirements without any retrofitting. The display and electrical connection can be rotated independently to maximize visibility while still orienting the electrical connection in the best position for the cable connector. Large, ergonomically designed push buttons allow for quickeasy programming and thin-film piezoresistive sensor technology guarantees long-term reliability and stability.

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023
Digital Process Meter
Model Number/NameSeries DPMA
BrandDWYER USA
Application

Industrial, Laboratory

Digital Process Meter

Series DPMA Adjustable LCD Digital Panel Meter offers a 3-12 digit display for easy viewing in a standard 18 DIN package. Unit accepts 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC inputs with a wide bipolar span and zero adjustment. Standard features include field selectable engineering units and decimal point positions. Choose from red, amber, or green segments for easy viewing at a distance. A 24 VDC power supply is required for the operation of the backlight.


  • Unit accepts : 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC


Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: DELHI
  • Production Capacity: 8368801023

 

 

Elementor #1182

Magnesense II Differential Pressure Transmitter

Rs 15,000  / Piece

ApplicationPHARMA
Power10 to 35 VDC (2-wire), 17 to 36 VDC or isolated 21.6 to 33 VAC (3-wire).
Response TimeAdjustable 0.5 to 15 sec. time constant. Provides a 95% response time of 1.5 to 45 seconds.
Product Weight8.0 oz (230 g).
Rated Supply Voltage10 to 35 VDC (2-wire), 17 to 36 VDC or isolated 21.6 to 33 VAC (3-wire).
BrandDwyer USA

Magnesense II Differential Pressure Transmitter

The Series MS2 Magnesense® II Differential Pressure Transmitter combines the proven stable piezo technology and the versatility of our original Series MS with additional features to reduce installation time and simplify ordering. Like the original Series MS, the second generation transmitter can be used as a linear pressure output or a linear velocity output with the square root extraction done in the transmitter. Additional parameters have been included to expand the square root capability to include flow measurements.

Features:

  • Field selectable ranges and output signal reduce inventory and the chances of ordering an incorrect part
  • BACnet® or Modbus® serial communications reduce wiring cost by daisy-chaining the transmitters
  • Our integral field-upgradeable display or plug-in remote display tool save upfront material cost and allow for local viewing of measurements


Specification:

  • Service : Air and non-combustible, compatible gases.
  • Typical Accuracy : ±1% FS for 0.15 in w.c. (40 Pa), 0.25 in w.c. (50 Pa), 0.5 in w.c. (125 Pa), 2 in w.c. (500 Pa), 3 in w.c. (750 Pa), 5 in w.c. (1250 Pa), 10 in w.c. (2 kPa), 15 in w.c. (3 kPa), 25 in w.c. (5 kPa), 28 in w.c. (6.975 kPa); ±2% FS for 0.1 in w.c. (25 Pa), 1 in w.c. (250 Pa), and all bi-directional ranges.
  • Zero & Span Adjustments : Digital push buttons.
  • Loop Resistance : Current Output: 0 to 1250 Ω max; Voltage Output: Min. load resistance 1 kΩ.


Applications
:

  • Duct Static Pressure in Commercial Buildings
  • Filter Monitoring in Air Handler Units
  • Building Pressure in Pharmaceutical-Semi-Conductor Clean Rooms
  • Air Velocity/Flow in VAV Systems

 

Other Details:

ModelDescription
MS2-W101-LCDDifferential pressure transmitter, wall mount, universal current/voltage outputs, low range (0.10, 0.15, 0.25, 0.50″ w.c.), uni-directional, LCD
MS2-W102-LCDDifferential pressure transmitter, wall mount, universal current/voltage outputs, middle range (1.0, 2.0, 3.0, 5.0″ w.c.), uni-directional, LCD
MS2-W103-LCDDifferential pressure transmitter, wall mount, universal current/voltage outputs, high range (10.0, 15.0, 25.0, 28.0″ w.c.), bi-directional, LCD
MS2-W103-LCD-MCDifferential pressure transmitter, wall mount, MODBUS® Communications, high range (10.0, 15.0, 25.0, 28.0″ w.c.), uni-directional, LCD
MS2-W111-LCDDifferential pressure transmitter, wall mount, universal current/voltage outputs, low range (0.10, 0.15, 0.25, 0.50″ w.c.), bi-directional, LCD
MS2-W112-LCDDifferential pressure transmitter, wall mount, simultaneous current/voltage outputs, selectable mid range (1.0, 2.0, 3.0, 5.0″ w.c.), bi-directional, LCD



Additional Information:

  • Item Code: Series-MS2

Molded Plastic Manometer

 

Rs 12,500  / Piece

ApplicationIndustrial
ModelSeries-Mark-II
Response TimeAdjustable 0.5 to 15 sec. time constant. Provides a 95% response time of 1.5 to 45 seconds.
ConditionNew
Accuracy+/-3% FS.
ConnectionNEW
BrandDwyer USA

Molded Plastic Manometer

SERIES MARK II Molded Manometers are of the inclined and inclined-vertical types. The curved inclined-vertical tube of the Model 25 gage provides higher ranges with more easily read increments at low readings. The Model 25 is excellent for general purpose work. The Model 40 inclined gage provides linear calibration and excellent resolution throughout its range. The Model 40 is ideally suited for air velocity and air filter gage applications. Both gage types are capable of pressure measurements above and below atmospheric as well as differential pressure measurements. Included with each Mark II manometer are two tubing connectors for 1/8″ pipe or sheet metal ducts, two mounting screws, 1 ounce bottle of indicating fluid, red and green pointer flags and complete instructions.
The Model 25 also includes 8′ of flexible double column plastic tubing. Portable operation of the Model 25 is made possible by the use of the optional A-612 portable stand. A short piece of tubing can be slipped over the Model 25 pressure connections to contain the gage fluid in transit.

The Model 40 contains two 4-1/2′ lengths of clear plastic tubing, a plastic swing-out stand and leveling screw for portable operation. It also features convenient rapid shutoff pressure connections and integral overpressure safety traps.

Features:

  • Broad ranging in easy to read calibrated increments
  • Gages ideally suited for general measurements and specific air applications
  • Compact, stationary or portable device, make it a simple to use tool for pressure measurement in OEM or user applications


Options:

  • OEM Specials – All Dwyer® Mark II Molded Plastic Manometers can be supplied in OEM quantities with your name and special graphics and scale.


Model Available:

ModelDescription
MARK II 25Molded plastic manometer, range 0-3″ w.c., red oil, .826 sp. gr.
MARK II 26Molded plastic manometer, range 0-7″ w.c., blue oil, 1.91 sp. gr.
MARK II 27Molded plastic manometer, range 0-7000 fpm, red oil, .826 sp. gr., requires Pitot tube *sold separately.
MARK II 28Molded plastic manometer, range 0-10,500 fpm, blue oil, 1.91 sp. gr., requires Pitot tube *sold separately.
MARK II M-700PAMolded plastic manometer, range 10-0-700 Pa, red oil, .826 sp. gr.
MARK II MM-180Molded plastic manometer, range 0-180 mm w.c., blue oil, 1.91 sp. gr.
MARK II MM-80Molded plastic manometer, range 0-80 mm w.c., red oil, .826 sp. gr.



Additional Information:

  • Item Code: Series-Mark-II

 

607 Differential Pressure Transmitter
r

Rs 20,500/ Piece

607 Differential Pressure Transmitter

Series 607 Differential Pressure Transmitter combines very low ranges with exceptional stability, reliability and either ±0.25% or ±0.5% accuracy for the most demanding applications. Ranges from 0-0.1″ to 0-25″ w.c. Ultra thin glass clad silicon diaphragm design resists shock and vibration, practically eliminates drift. Certification to NIST standards is included with each unit. Tough stainless steel housing is NEMA 2 rated to protect against moisture and dirt. Use with air and other compatible gases.

Features:
 

  • High stability at low pressure ranges provides exceptional accuracy for ensuring tight-control and minimizing costly out of specification conditions
  • Provides sensitivity to pressure changes but resists vibration preventing drift and less accurate readings
  • Stainless steel housing meets standards for lab and clean room applications

Specification:

  • Service : Air and non-conductive, non-corrosive gases.
  • Wetted Materials : Consult factory.
  • Thermal Effects : ±0.015% F.S./°F (zero and span).
  • Zero and Span Adjustments : Externally accessible potentiometers, non-interactive, ±10% F.S. adjustment.
  • Loop Resistance : 0 to 1045 ohms Vmin=12V+[(.22A)(RL)].
  • Electrical Connections : Screw terminals.
  • Process Connections : Barbed stainless steel for 3/16″ I.D. tubing.
  • Housing : 300 Series stainless steel (NEMA 2).


Applications:
 

  • Leak Detection
  • Clean Room Control
  • Lab and Fume Hood Pressure Control

 

Other Details:

ModelDescription
607-0Differential pressure transmitter, range 0-.10″ w.c.
607-0BDifferential pressure transmitter, range .10-0-.10″ w.c.
607-1Differential pressure transmitter, range 0-.25″ w.c.
607-1BDifferential pressure transmitter, range .25-0-.25″ w.c.
607-2Differential pressure transmitter, range 0-.50″ w.c.
607-2BDifferential pressure transmitter, range .50-0-.50″ w.c.
607-3Differential pressure transmitter, range 0-1.0″ w.c.
607-3BDifferential pressure transmitter, range 1.0-0-1.0″ w.c.
607-4Differential pressure transmitter, range 0-2.0″ w.c.
607-4BDifferential pressure transmitter, range 2.0-0-2.0″ w.c.
607-7Differential pressure transmitter, range 0-5.0″ w.c.
607-7BDifferential pressure transmitter, range 5.0-0-5.0″ w.c.
607-8Differential pressure transmitter, range 0-10″ w.c.
607-9Differential pressure transmitter, range 0-25″ w.c.

Request

 

 

645 Wet Differential Pressure Transmitter

Rs 19,500  / Piece

BrandDWYER USA

645 Wet Differential Pressure Transmitter

SERIES 645 Wet/Wet Differential Pressure Transmitters are designed for use with compatible gases and liquids which can be applied to both the pressure and reference ports. Quick response capacitance sensor delivers a 4 to 20 mA output signal proportional to differential pressure with ±.25% accuracy. The Series 645 transmitters are ideal for process control, filter condition monitoring, refrigeration equipment, pump speed control, HVAC equipment, and liquid level measurement. For ease of installation and maintenance, order optional 3-valve manifold assembly. Bleed ports allow for total elimination of air in the line and pressure cavities.

Specification:

  • Service : Compatible gases or liquids on both pressure and reference sides.
  • Wetted Materials : 17-4 PH stainless steel, 300 Series stainless steel, fluoroelastomer and silicone O-rings and bleed screw seals.
  • Pressure Limits : (High side) 1 to 5 psi: 20 x FS, 10 to 25 psi: 10 x FS, 50 psi: 5 x FS, 100 psi: 2.5 x FS; (low side) 2.5 x FS.
  • Thermal Effects : (includes zero and span) ±0.02% FS/°F, 30 to 150°F (-1 to 65°C).
  • Zero and Span Adjustments : Adjustable, ±1 mA, non-interactive.
  • Loop Resistance : 0 to 1000Ω.
  • Electrical Connection : Barrier strip terminal block with conduit enclosure and .875″ (22 mm) diameter conduit opening.
  • Manifold : Brass.
  • Valve Type : 90° on/off.
  • Process Connection : 1/4″-18 female NPT.


 
Features: 

  • Versatile, high-accuracy device for liquid or gas supports designs requiring more precise measurements in support of application
  • Optional 3-way valve manifold supports simplifying installation or removal of transmitter without interrupting process


Applications:

  • Process control
  • Filter monitoring
  • Refrigeration equipment
  • Pump speed control
  • HVAC equipment
  • Liquid level measurement

Other Details:

ModelDescription
645-0Wet/wet differential pressure transmitter, range 0-1 psid.
645-1Wet/wet differential pressure transmitter, range 0-2 psid.
645-10Wet/wet differential pressure transmitter, range ±0.5 psid.
645-11Wet/wet differential pressure transmitter, range ±1 psid.
645-12Wet/wet differential pressure transmitter, range ±2.5 psid.
645-13Wet/wet differential pressure transmitter, range ±5 psid.
645-14Wet/wet differential pressure transmitter, range ±10 psid.
645-15Wet/wet differential pressure transmitter, range ±25 psid.
645-16Wet/wet differential pressure transmitter, range ±50 psid.
645-2Wet/wet differential pressure transmitter, range 0-5 psid.
645-3Wet/wet differential pressure transmitter, range 0-10 psid.
645-4Wet/wet differential pressure transmitter, range 0-25 psid.
645-5Wet/wet differential pressure transmitter, range 0-50 psid.
645-6Wet/wet differential pressure transmitter, range 0-100 psid.

DM-2000 Differential Pressure Transmitter

 

Rs 18,500  / Piece

BrandDWYER USA
ApplicationPHARMA


DM-2000 Differential Pressure Transmitter

The Dwyer Series DM-2000 Differential Pressure Transmitter senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. The DM-2000 housing is specifically designed to mount in the same diameter cutout as a standard Magnehelic® gage. A wide range of models are available factory calibrated to specific ranges.

 

Pressure connections are inherent to the glass filled plastic molded housing making installation quick and easy. Digital push-button zero and span simplify calibration over typical turn-potentiometers. An optional 3.5 digit LCD shows process and engineering units. A single push button allows field selection of 4 to 6 engineering units depending on range.

 

Features: 

  • Zero and span controls provide easy calibration checks and shorter installation time to get device running and monitoring
  • Quick response to pressure changes means no delay in signaling and alerting to critical situations
  • Easy to read LCD display provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread
  • Same size as Magnehelic simplifies field upgrade to digital pressure gage by reducing install steps
  • Tamper proof button configuration to prevent accidental changes to the settings

Specification:

  • Thermal Effect : ±0.055% F.S./°F (0.099% F.S./°C).
  • Zero and Span Adjustments : Digital push-button zero and span.
  • Electrical Connections : Screw-type terminal block.


Applications:

  • Filter monitoring
  • Fan pressure indication
  • Static pressures in ducts or buildings
  • Bi-direction ranges ideal for sensing fluctuating building pressure

 

Other Details:

ModelDescription
DM-2001-LCDDifferential pressure transmitter, range .100″ w.c., 24.9 Pa, 2.54 mm w.c., .249 mbar, with LCD.
DM-2002-LCDDifferential pressure transmitter, range .250″ w.c., 62.2 Pa, 6.35 mm w.c., .622 mbar.
DM-2003-LCDDifferential pressure transmitter, range .500″ w.c., 124.3 Pa, 12.70 mm w.c., 1.243 mbar, .124 kPa.
DM-2004-LCDDifferential pressure transmitter, range 1.00″ w.c., 249 Pa, 25.4 mm w.c., 2.49 mbar, .249 kPa.
DM-2005-LCDDifferential pressure transmitter, range 2.00″ w.c., 497 Pa, 50.8 mm w.c., 4.97 mbar, .497 kPa.
DM-2006-LCDDifferential pressure transmitter, range 3.00″ w.c., 746 Pa, 76.2 mm w.c., 7.46 mbar, .746 kPa, .108 psi.
DM-2007-LCDDifferential pressure transmitter, range 5.00″ w.c., 1243 Pa, 127.0 mm w.c., 12.43 mbar, 1.243 kPa, .180 psi.
DM-2012-LCDDifferential pressure transmitter, range .250-0-.250″ w.c., 62.2-0-62.2 Pa, 6.35-0-6.35 mm w.c., .622-0-.622 mbar.
DM-2013-LCDDifferential pressure transmitter, range .500-0-.500″ w.c., 124.3-0-124.3 Pa, 12.70-0-12.70 mm w.c., 1.243-0-1.243 mbar.
DM-2019-LCDDifferential pressure transmitter, range .05-.200″ w.c., 49.8 Pa, 5.08 mm w.c., 498 mbar.

Differential Pressure Indicating Transmitter

Rs 8,500  / Piece

BrandDWYER USA
Product Weight7.8 oz (221 g).
Rated Supply Voltage

DC 38 mA max.

Differential Pressure Indicating Transmitter

Series 621 Pressure Indicator is a 1/8 DIN measuring and con trol ling instrument designed for positive, negative or differential pres sures of air and compatible gases. Pres sure readings are dis played on a large 3-1/2 digit LCD dis play while unit simultaneously pro duc es a standard 4-20 mA output signal. Over a dozen stocked rang es are available from 0-3 in. w.c. to 0-100 psid or choose metric units in rang es from 0-0.75 kPa to 0-690 kPa. Circuit design enables use in 2-wire current loops.

Specification:

  • Service : Air and non-combustible, compatible gases.
  • Thermal Effect : 0.025% F.S./°F (0.045% F.S./°C).
  • Zero and Span Adjustments : Accessible potentiometers.
  • Electrical Connections : Terminal block.
  • Process Connections : Barbed for 1/8″ (3.18 mm) I.D. tubing.
  • Enclosure Rating : Face designed to meet NEMA 4 (IP66).
  • Mounting Orientation : Not position sensitive.

Installation:
Location: Select a location where the temperature of the unit will be between 20°F and 120°F. Distance from the receiver is limited only by total loop resistance. See Electrical Connections. The tubing feeding pressure to the instrument can be run practically any length required but long lengths will increase response time slightly. Mount the instrument in a location that will not be subject to excessive temperature, shock or vibration. All models are designed for mounting in an enclosed panel. 

Select the mounting position for the instrument on the panel. Prepare the panel by cutting and debarring the required opening. Refer to Figure A. 

From the front panel, slide the instrument through the cutout. The housing gasket should be against the housing flange before installing. From the rear of the panel slide the mounting collar over the housing. Hold the housing with one hand and using the other hand, push the collar evenly against the panel until the springs are com-pressed. The ratchets will hold the mounting collar and housing in place. 

Other Details:

ModelRangeMax. Press.
621-30-3 in w.c.5 psig
621-60-6 in w.c.5 psig
621-100-10 in w.c.5 psig
621-200-20 in w.c.11 psig
621-400-40 in w.c.11 psig
621-1000-100 in w.c.29 psig
621-2000-200 in w.c.29 psig
621-10000-1000 in w.c.150 psig
621P-100-10 psid58 psig
621P-200-20 psid58 psig
621P-300-30 psid58 psig
621P-500-50 psid150 psig
621P-1000-100 psid150 psig



Additional Information:

  • Item Code: Series-621

Differential Pressure Switch

 

Rs 2,500  / Piece

BrandDWYER USA
Model No.Series-1950
Rated Supply VoltageDC 38 mA max.

Differential Pressure Switch

Series 1950 Explosion-Proof Differential Pressure Switch combines the best features of the popular Dwyer® Series 1900 Pressure Switch with an integral explosion-proof and weatherproof housing, making it an exceptional value for either application. It is CE, UL and CSA listed, FM approved for use in Class I, Div 1, Groups C and D, Class II Groups E, F, and G and Class III hazardous atmospheres (NEMA 7 & 9), Raintight NEMA 3 (IP54). Weatherproof features include a drain plug and O-ring seal in cover. Electrical connections are easily made by removing front cover. For convenience the set point adjustment screw is located on the outside of the housing. Twelve models offer set points from .03 to 20 in w.c. (0.0075 to 5 kPa) and from .5 to 50 psi (0.035 to 3.5 bar). The unit is very light and compact — about half the weight and bulk of other explosion-proof or weather-proof switches with separate enclosures.

Features: 

  • Explosion-proof and weatherproof housing provides device protection for outdoor use or harsh environment operation
  • External set point screw provides easy access that simplifies making adjustments without opening or disassembling enclosure
  • Easily accessible electrical connection simplifies the installation


Specification:

  • Service : Air and non-combustible, compatible gases.
  • Temperature Limits : -40 to 140°F (-40 to 60°C); 0 to 140°F (-17.8 to 60°C)for 1950P-8, 15, 25, and 50. -30 to 130°F (-34.4 to 54.4°C) for 1950-02.
  • Pressure Limits : Continuous: 1950”s – 45″ w.c. (0.11 bar); 1950P”s – 35 psi (2.41 bar); 1950P-50 only – 70 psi (4.83 bar). Surge: 1950”s – 10 psi (0.69 bar); 1950P”s – 50 psi (3.45 bar); 1950P-50 only – 90 psi (6.21 bar).
  • Electrical Rating : 15 A @ 125, 250, 480 VAC, 60 Hz. Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
  • Mounting Orientation : Diaphragm in vertical position. Consult factory for other position orientations.
  • Set Point Adjustment : Screw type on top of housing..


Applications:

  • HVAC applications
  • Process applications
  • All-weather applications


Other Details:

ModelDescription
1950-00-2FDifferential pressure switch, range .07-.15″ w.c., approx. deadband @ min. set point 0.04, approx. deadband @ max. set point 0.05.
1950-02-2SDifferential pressure switch, range .03-.10″ w.c., approx. deadband @ min. set point 0.025, approx. deadband @ max. set point 0.05.
1950-0-2FDifferential pressure switch, range .15-.50″ w.c., approx. deadband @ min. set point 0.10, approx. deadband @ max. set point 0.15.
1950-10-2FDifferential pressure switch, range 3-11″ w.c., approx. deadband @ min. set point 0.40, approx. deadband @ max. set point 0.50.
1950-1-2FDifferential pressure switch, range .4-1.6″ w.c., approx. deadband @ min. set point 0.15, approx. deadband @ max. set point 0.20.
1950-20-2FDifferential pressure switch, range 4-20″ w.c., approx. deadband @ min. set point 0.40, approx. deadband @ max. set point 0.60.
1950-5-2FDifferential pressure switch, range 1.4-5.5″ w.c., approx. deadband @ min. set point 0.30, approx. deadband @ max. set point 0.40.




Additional Information:

  • Item Code: Series-1950

Differential Pressure Transmitter Low Ranges

Rs 3,750  / Piece

BrandDWYER USA
Model No.Series-616KD-LR

Differential Pressure Transmitter Low Ranges

The SERIES 616KD-LR Differential Pressure Transmitter is designed for simplicity, making it the ideal choice for installers and maintenance professionals. These low range instruments not only alleviate cumbersome turn pots typically found in most transmitters, but eliminate entirely the need to span the instruments during calibration. With single digital push button, both ZERO AND SPAN are calibrated properly, nothing else is required. No additional reference pressure sources or separate calibration devices are necessary.

Specification:

  • Service : Air and non-combustible, compatible gases.
  • Accuracy : ±0.25% FS for ±0.4″ (100 Pa) and ±0.5″ (125 Pa), ±0.5% FS for ±0.25″ (60 Pa), and ±1% FS for ±0.1″ (25 Pa).
  • Zero and Span Adjustments : Push buttons.
  • Loop Resistance : Current Output: 0 to 1250Ω max; Voltage Output: Min. load resistance 1kΩ.
  • Electrical Connections : Screw type terminal block.
  • Process Connections : Barbed, dual size to fit 1/8″ & 3/16″ (3 mm & 5 mm) ID rubber or vinyl tubing, or 1/4″ NPT.
  • Mounting Orientation : Vertical with pressure connections pointing down.


Features:

  • Wide selection of low ranges and accuracy cover numerous applications minimizing components and standardizing on design
  • Simple calibration push-buttons to set zero and span, saving time installing and maintaining over the service life
  • Cost effective and compact device suitable for OEM applications where space, simplicity, and value are key
  • Simultaneous current and voltage outputs
  • Optional 1/4″ NPT process connection allows for use with metal barbed fittings or compression fittings for use with metal tubing


Applications:

  • Air handlers
  • Variable air volume
  • Duct pressure
  • Filter monitoring

 

Options:

  • AT Aluminum Tag
  • COC Certificate of Conformance
  • FC Factory Calibration Certificate
  • NIST NIST Traceable Calibration Certificate
  • TC Terminal Cover

 

Other Details:

ModelDescription
616KD-LR-A34-BD1Low range differential pressure transmitter, 0.4″ wc with 0.25% accuracy, barb process connection, and dual 4-20mA & 0-10V output.
616KD-LR-A34-ND1Low range differential pressure transmitter, 0.4″ wc with 0.25% accuracy, NPT process connection, front Zero push button, and dual 4-20mA & 0-10V output.
616KD-LR-A45-BD1Low range differential pressure transmitter, +/- 0.5″ wc with 0.25% accuracy, barb process connection, and dual 4-20mA & 0-10V output.
616KD-LR-A45-ND1Low range differential pressure transmitter, +/- 0.5″ wc with 0.25% accuracy, NPT process connection, front Zero push button, and dual 4-20mA & 0-10V output.



Additional Information:

  • Item Code: Series-616KD-LR

Digihelic Differential Pressure Controller

Rs 27,500  / Piece

ModelDWYER USA
Code NumberSeries-DH3
Model NumberSeries-DH3
ConditionNew
WarrantyYAS
BrandDwyer USA

Digihelic Differential Pressure Controller

The Series DH3 Digihelic® Differential Pressure Controller is a 3-in-1 instrument possessing a digital display gage, control relay switches, and a transmitter with current output all packed in the popular Photohelic® gage style housing. Combining these 3 features allows the reduction of several instruments with one product, saving inventory, installation time and money. The Digihelic® controller is the ideal instrument for pressure, velocity and flow applications, achieving a 1% full scale accuracy on ranges down to the extremely low 0.25″ w.c. to 2.5″ w.c. full scale. Ranges of 5″ w.c. and greater maintain 0.5% F.S. accuracy. Bi-directional ranges are also available.

 The Series DH3 Digihelic® controller allows the selection of pressure, velocity or volumetric flow operation in several commonly used engineering units. 2 SPDT control relays with adjustable deadbands are provided along with a scalable 4-20 mA process output.

 Programming is easy using the menu key to access 5 simplified menus which provide access to: security level; selection of pressure, velocity or flow operation; selection of engineering units; K-factor for use with flow sensors; rectangular or circular duct for inputting area in flow applications; set point control or set point and alarm operation; alarm operation as a high, low or high/low alarm; automatic or manual alarm reset; alarm delay; view peak and valley process reading; digital damping for smoothing erratic process applications; scaling the 4-20 mA process output to fit your applications range and field calibration.

Features:

  • 3-in-1 instrument allows the reduction of several instruments with one product, saving inventory, installation time and money
  • Full scale accuracy of 1% even on extremely low ranges, and 0.5% for ranges above 5 in w.c. provide for greater measurement precision
  • Secure menu program provides access to device operation only for the right skill level

Specification:

  • Service : Air and non-combustible, compatible gases.
  • Accuracy : ±1.5% for 0.25″ and ±0.25″ w.c. ranges. Ranges 0.5″ to 5″ w.c. and corresponding bi-directional (except ±2.5″ w.c.) ±1%; All other ranges: ±0.5% @ 77°F (25°C) including hysteresis and repeatability (after 1 hour warm-up).
  • Pressure Limits : Ranges ≤ 2.5 in w.c.: 25 psi; ±2.5″, 5 in w.c.: 5 psi; 10 in w.c.: 5 psi; 25 in w.c.: 5 psi; 50 in w.c.: 5 psi; 100 in w.c.: 9 psi.
  • Thermal Effects : 0.020%/°F (0.036/°C) from 77°F (25°C). For 0.25″ and ±0.25″ w.c. ranges: ±0.03%/°F (±0.054%/°C).
  • Display : Backlit 4 digit LCD 0.4″ height LED indicators for set point and alarm status.
  • Electrical Connections : 15 pin male high density D-sub connection. 18″ (46 cm) cable with 10 conductors included.
  • Process Connections : 1/8″ female NPT. Side or back connections.

 Other Details:

ModelDescription
DH3-002Differential Pressure Controller, range 0-0.25″ w.c.
DH3-003Differential Pressure Controller, range 0-0.5″ w.c.
DH3-004Differential Pressure Controller, range 0-1″ w.c.
DH3-005Differential Pressure Controller, range 0-2.5″ w.c.
DH3-006Differential Pressure Controller, range 0-5″ w.c.
DH3-007Differential Pressure Controller, range 0-10″ w.c.
DH3-009Differential Pressure Controller, range 0-25″ w.c.
DH3-010Differential Pressure Controller, range 0-50″ w.c.
DH3-011Differential Pressure Controller, range 0-100″ w.c.



Additional Information:

  • Item Code: Series-DH3

Magnehelic Differential Pressure Gauges

Rs 3,300  / Piece

BrandDWYER USA
ConnectionNew
ConditionNew
Battery IncludedNo
Display TypeNO
Model NumberSeries-2000

Magnehelic Differential Pressure Gauges
Select Series 2000 Magnehelic®Gauges for a versatile low differential pressure gage with a wide choice of 81 models and 27 options to choose from.Using Dwyer’s simple,frictionless Magnehelic®gage movement,it quickly indicates air or noncorrosive gas pressures either positive,negative vacuum or differential.The design resists shock,vibration,over-pressures and is weatherproof to IP67.Select the HA High Accuracy Magnehelic®Gage option for an accuracy within 1% of full scale, located below in the Product Configurator
Features

  • Easy to read gage through undistorted plastic face permits viewing from far away
  • Patented design provides quick response to pressure changes means no delay in assessing critical situations
  • Durable and rugged housing and high-quality components combine to provide longservice life and minimized down-time
  • High accuracy option is twice as accurate as the standard Magnehelic® gage
  • Bezel provides flange for flush mounting in panel
  • Clear plastic face is highly resistant to breakage.Provides undistorted viewing of pointer and scale
  • Precision litho-printed scale is accurate and easy to read
  • Red tipped pointer of heat treated aluminum tubing is easy to see.It is rigidly mounted on the helix shaft

Applications
Filter Monitoring

  • Air Velocity with Dwyer Pitot Tube
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

Model Available

ModelDescription
2000-0Differential pressure gage,range 0-0.50″ w.c.,minor divisions .01,calibrated for vertical scale position.
2000-00Differential pressure gage,range 0-0.25″ w.c.,minor divisions .005,calibrated for vertical scale position.
2000-00NDifferential pressure gage,range .05-0-.2″ w.c., minor divisions .005,calibrated for vertical scale position.
2001Differential pressure gage,range 0-1.0″ w.c.,minor divisions .02.
2002Differential pressure gage,range 0-2.0″ w.c.,minor divisions .05.
2003Differential pressure gage,range 0-3.0″ w.c.,minor divisions .10.
2004Differential pressure gage,range 0-4.0″ w.c.,minor divisions .10.
2005Differential pressure gage,range 0-5.0″ w.c.,minor divisions .10.
2006Differential pressure gage,range 0-6.0″ w.c.,minor divisions .20.
2008Differential pressure gage,range 0-8.0″ w.c.,minor divisions .20.
2010Differential pressure gage,range 0-10″ w.c.,minor divisions .20.
2015Differential pressure gage,range 0-15″ w.c.,minor divisions .50.
2020Differential pressure gage,range 0-20″ w.c.,minor divisions .50.
2025Differential pressure gage,range 0-25″ w.c.,minor divisions .50.
2030Differential pressure gage,range 0-30″ w.c.,minor divisions 1.0.
2040Differential pressure gage,range 0-40″ w.c.,minor divisions 1.0.
2050Differential pressure gage,range 0-50″ w.c.,minor divisions 1.0.
2060Differential pressure gage,range 0-60″ w.c.,minor divisions 2.0.
2080Differential pressure gage,range 0-80″ w.c.,minor divisions 2.0.
2100Differential pressure gage,range 0-100″ w.c., minor divisions 2.0.
2150Differential pressure gage,range 0-150″ w.c.,minor divisions 5.0.




Additional Information:

  • Item Code: Series-2000

Mini Photohelic Differential Pressure Switch Gauge

Rs 25,500  / Piece

BrandDWYER USA
ConnectionNew
ConditionNew
Pressure Limits30 psig (2.067 bar).
Model NumberSeries-MP

Mini Photohelic Differential Pressure Switch Gauge

The Series MP Mini-Photohelic® Differential Pressure Switch/Gage combines the time proven Minihelic® II differential pressure gage with two SPDT switching set points. The Mini-Photohelic® switch/gage is designed to measure and control positive, negative, or differential pressures consisting of non-combustible and non-corrosive gases. Gage reading is independent of switch operation. Switching status is visible by LED indicators located on the front and rear of the gage. Set points are adjusted with push buttons on the back of the unit.

Features:

  • Gage reading unaffected by switch operation and will continue to read pressure even during power loss
  • Visible switch status LED provides indication of set point switching state
  • Compact design but with the power of larger devices can meet the same application specifications


Applications:

  • Fume hoods
  • Dust collection
  • Pneumatic conveying
  • Clean room


Options:

  • For optional 1/8″ male NPT connections, add suffix -NPT to model numbers.
    Example: MP-000-NPT. No extra charge. Allow additional lead time.


Specification:

  • Service : Air and non-combustible, compatible gases.
  • Accuracy : ±5% FS @ 70°F (21.1°C). Gage face mounted in vertical position.
  • Process Connections : Barbed for 3/16″ ID tubing (STD); 1/8″ male NPT (optional).
  • Electrical Connections : Screw type terminal block. Accepts 22-12 AWG wire.
  • Mounting Orientation : Gage face in vertical position.
  • Set Point Adjustment : Push buttons.
  • Standard Accessories : 2) mounting screws, (1) .050″ hex allen wrench.


Other Details:

ModelDescription
MP-000Differential pressure switch/gage, range 0-0.5″ water.
MP-001Differential pressure switch/gage, range 0-1.0″ water.
MP-002Differential pressure switch/gage, range 0-2.0″ water.
MP-003Differential pressure switch/gage, range 0-3.0″ water.
MP-005Differential pressure switch/gage, range 0-5.0″ water.
MP-010Differential pressure switch/gage, range 0-10″ water.
MP-020Differential pressure switch/gage, range 0-20″ water.



Additional Information:

  • Item Code: Series-MP

Digital Differential Pressure And Flow Gauges

 

Rs 8,500  / Piece

BrandDWYER USA
ConnectionNew
Display TypeYAS
Battery IncludedYes

Digital Differential Pressure and Flow Gauges

The DigiMag® Series DM-1000 Digital Differential Pressure and Flow Gages monitor the pressure of air and compatible gases just as its famous analog predecessor the Magnehelic® Differential Pressure Gage. All models are factory calibrated to specific ranges. The 4-digit LCD can display readings in common English and metric units so conversions are not necessary. The simplified four button operation reduces set up time and simplifies calibration with its digital push button zero and span.

Specification:

  • Accuracy : ±1% FS including linearity, hysteresis and repeatability; ±2% FS for ranges 1″ w.c. and below.
  • Thermal Effect : ±0.05% FS/°F typ.; ±0.10% FS/°F typ. for ranges 1″ w.c. and below.
  • Display Update : Selectable for 1 second, 10 minutes or update only from button push.
  • Pressure Limits : Normal and bi-directional ranges 5 in w.c. and lower = 2 psi (13.7 kPa); Normal and bi-directional ranges 10 in w.c. and higher = 11 psi (75 kPa).
  • Selectable Engineering Units : in w.c., psi, kPa, Pa, mm w.c., mBar, in Hg, mm Hg, FS (0-100% FS).
  • Power Requirements : 9V battery, included, user replaceable or external power supply 9-24 VDC.
  • Battery Service Life : Battery life depending on the Display Update setting: 150 hours (typical) if Display Update = 1 second; 9 months (typical) if Display Update = 10 minutes; 1.5 years (typical) if Display Update is disabled. Battery may last up to four times longer when using lithium-based battery ULTRALIFE U9VL-J.


Features:

  • Field programmed reduces installation time
  • User selectable parameters for pressure, air velocity or flow permits same device for multiple applications
  • Specialized filter set point for alerts when maintenance is due
  • Security levels permit matches the correct access to right skill


Applications:

  • Filter monitoring
  • Air velocity or flow
  • Blower vacuum monitoring
  • Fan pressure indication
  • Duct, room or building pressures
  • Clean room positive pressure indication


Other Details:

ModelDescription
DM-1102DigiMag® differential digital pressure gage, range 0-0.25″ w.c.
DM-1103DigiMag® differential digital pressure gage, range 0-0.5″ w.c.
DM-1104DigiMag® differential digital pressure gage, range 0-1″ w.c.
DM-1105DigiMag® differential digital pressure gage, range 0-2″ w.c.
DM-1107DigiMag® differential digital pressure gage, range 0-5″ w.c.
DM-1108DigiMag® differential digital pressure gage, range 0-10″ w.c.
DM-1109DigiMag® differential digital pressure gage, range 0-15″ w.c.
DM-1110DigiMag® differential digital pressure gage, range 0-25″ w.c.
DM-1111DigiMag® differential digital pressure gage, range 0-50″ w.c.
DM-1112DigiMag® differential digital pressure gage, range 0-100″ w.c.
DM-1122DigiMag® differential digital pressure gage, range 0.25-0-0.25″ w.c.
DM-1123DigiMag® differential digital pressure gage, range 0.5-0-0.5″ w.c.
DM-1124DigiMag® differential digital pressure gage, range 1-0-1″ w.c.
DM-1125DigiMag® differential digital pressure gage, range 2-0-2″ w.c.
DM-1127DigiMag® differential digital pressure gage, range 5-0-5″ w.c.
DM-1128DigiMag® differential digital pressure gage, range 10-0-10″ w.c.



Additional Information:

  • Item Code: Series-DM-1000

Elementor #1101

Duct Air Flow Measuring Probe

Rs 10,500 / Piece

BrandDwyer Usa
Accuracy+/-2%
Flow range400 fpm (2.03 m/s). TO 12000 fpm (60.96 m/s).
ConditionNew


Duct Air Flow Measuring Probe

The DAFM Model Duct Air Flow Measuring Probe :
Uses evenly distributed total and static pressure measuring points to deliver an accurate measurement of flows in a duct. The Air Flow Measuring Probe can be completely installed from outside of the duct making it very easy to install. With its lightweight and durable construction in addition to its ease of installation, this product lends itself to being used in the HVAC industry. These air flow measuring probes may be ordered to fit into either round or rectangular duct installations.

Installation:
When you unpack the Model DAFM Duct Air Flow Measurement Probe ensure that there is no visible damage from shipping. Inspect each sensing point on the probes to ensure that they are not filled with debris from shipping. If there is obvious shipping damage, the probe must be replaced prior to use in order to avoid inaccurate measurements. Please contact Dwyer Instruments, Inc. if it is necessary to replace your air flow measurement probe.

Rectangular Duct Models:
Determining Probe Number and Placement for Rectangular Ducts

  • To determine the number of probes you need please consult the chart below.
  • In order to determine where to place your probes, divide the short duct dimension by number of probes.
  • Divide the result by two and this will be the distance from the side of the duct to the first probe location.
  • The next probe will be placed two times the resulting distance from step two from the first probe. So, if the first probe was placed 4 ̋ from the side of the duct, your next probe would be placed 8” from the first probe, or 12 ̋ from the side of the duct.
  • Continue this pattern until you have determined all probe locations.

 

Rectangular Duct Probe Installation:

  • Cut 4 ̋ X 1 ̋ holes at locations calculated above in side of duct.
  • Place silicon bead around holes.
  • Slide DAFM into holes and screw four self drilling screws into duct to attach DAFM.
  • Connect 1/4 ̋ OD plastic tubing to barb fittings on DAFM.
  • Check all fittings and tubing connections for leaks using a leak detector.
  • Tee all high and low ports into one high and one low line and connect to transmitter or gage.
  • The devices should be checked once a year for build-up of dirt of debris common in an HVAC system.

Circular Duct Models:

  • Determining Probe Number and Location for Round Ducts Note that in round ducts only two probes are needed. The quantity of probes needed does not depend on size of the duct.
  • Locate probes 90 degrees apart. See Figure 2 for an example.


Calibration:

Sometimes field calibration may be required if the probe is installed in a bad location i.e. immediately downstream of an elbow. In order to calibrate, you must either perform a traverse of the duct or a sum of the air registers and compare this with the DAFM output. Then, you must make the correction to the effective area in the computer to make up for the error.


Maintenance:

Upon final installation, the device should be checked once a year for a build up of dirt or debris that can be common in an HVAC system. Also check the mounting stability once a year. Other than this no routine maintenance is required. The DAFM model is not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty). Be sure to include a brief description of the problem plus any relevant application notes. Contact customer service to receive a return goods authorization number.

Air Flow Switch

Rs 2,950 / Piece

BrandDwyer Usa
WarrantyYAS
ConditionNew

Air Flow Switch

The SERIES AVFS Adjustable Air Flow Switch is specifically designed to monitor air flow in ducts and provides a 3 A contact output to indicate a change or loss of flow. The AVFS provides a ±5% set-point repeatability across a full scale range of 1-10 m/s (197-1969 fpm) and includes a mounting bracket for quick duct mounting.
Application:Fan monitoring Filter monitoring Damper feedback Air handler 
The new Series AVFS Adjustable Air Flow Switch complements  the  Dwyer Instruments line of thermo-anemometer transmitters and handheld instruments. The AVFS is specifically designed to monitor air flow in ducts and provides a 3A contact output to indicate a change or loss of flow. Simply turn on the fan or air handling unit and adjust the set-point via the potentiometer to show normal status. Then alter a damper or decrease fan speed to activate the AVFS. The AVFS will signal a loss of flow and the N.O. SPST output will indicate the detected decrease. For ease of installation and system trouble-shooting, the Series AVFS possesses a red/green LED indication to provide local status if the air flow is above (green) or below (red) the set-point.  The AVFS Series Adjustable Air Flow Switches come in a compact, rugged PBT enclosure that is rated NEMA 4X (IP65), making them ideal for any ventilation system installation or similar BAS application. 
Mounting:Mount the airflow monitor by means of the mounting clamp provided. Diameter of the mounting hole for the unit: .9 in (24 mm) mm. If mounting is to be airtight, use the gasket provided. The sensing head must be completely immersed into the airflow and should be in the range of the highest flow velocity, if possible. 
Maintenance:Upon final installation of the Series AVFS Air Flow Switch, no routine maintenance is required. The Series AVFS is not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty). Be sure to include a brief description of the problem plus any relevant application notes. Contact customer service to receive a return goods authorization number before shipping.

Air Velocity Transmitter

Rs 38,500 / Piece

BrandDwyer Usa
ConditionNew

Air Velocity Transmitter

The SERIS AVU Air Velocity Transmitter is ideal for a wide range of HVAC measurement and control applications, particularly in complete building control and energy management systems. The Series AVU Transmitter operates by measuring the heat loss from one of the two sensing elements in the air stream, then calculating the air velocity. Units are virtually immune to drift due to the design of the sensing element, which makes the transmitter accurate over the whole air velocity range.
The  Series  AVU  Air  Velocity  Transmitters from  Dwyer Instruments  are  suitable  for  measuring  air  velocity  within  a  duct and giving 4-20 mA or 0-10 V linear outputs. A typical application would be in a VAV air conditioning system. 
The transmitters operate by measuring the heat loss from one of two sensing elements in the airstream and hence calculating the air velocity. The special design of these elements makes the transmitter accurate over the whole air velocity range and gives excellent immunity to drift. 
The sensing elements are clad in metal ensuring a long service life and enabling the sensors to be cleaned easily. 
Installation:Electromagnetic CompatibilitySeries AVU Air Velocity Transmitters have built in immunity to electrical interference. However, to achieve full immunity meeting the standards described below, a screened cable must be used correctly. The cable screen must be earthed at the enclosure of the controller/power  supply  and  connected  to  the  screen  inside  the AVU casing using the procedure described on the back page. The inside of the transmitter and the sensing elements near the end ofthe probe must be protected from electrostatic discharge at all times.

Averaging Flow Sensor

Rs 2,500 / Piece

BrandDwyer Usa

Averaging Flow Sensor

The  Series  SSS-1000  Lightweight  Averaging  Flow Sensor From  Dwyer  Instruments,  Inc.  is  ideal  for  sensing differential pressure in the inlet section of variable air volume terminal units and fan terminal units. They can also be used to sense differential pressure at other locations in the main,or branch duct systems.
The Series SSS-1000 Lightweight Flow Sensor is ideal for sensing differential pressure in the inlet section of variable air volume terminal units and fan terminal units. Units can also be used to sense differential pressure at other locations in the main or branch duct systems.
The “H” port senses total pressure and the “L” port senses static pressure. The difference between these signals is the differential, or velocity pressure.Models  offer  up  to  four  sensing  points  and  lengths  of  3- 5/32 ̋ to 9-29/32 ̋ (8.02 to 25.26 cm) to accommodate box size diameters of 4 ̋  to 16 ̋ (10.16 to 40.64 cm)
Installation:The Series SSS-1000 utilizes 1/4 ̋ I.D. tubing for 3/8 ̋ O.D. tubing. First check that there are no sharp bends in the tubing  at  any  connection.  Bends  and  creases  may  leak  over time as the tubing ages. Connect  the  “H”  Port    to  the  high  input  on  the  differential pressure gage, transmitter, or switch.Connect  the  “L”  Port  to  the  low  input  on  the  differential pressure gage, transmitter, or switch.
Mounting:Install  the  unit  horizontally  to  assure  accurate  velocity readings.Determine the duct’s flow direction and install the Series SSS-1000 based on the unit’s flow arrow imprint.Cut a 7/8 ̋ hole in the ducting to accept the unit.Attach using two self-tapping screws inserted in the 3/16 ̋ mounting holes.
Maintenance:Sensing orifices must be kept free of dust accumulation or debris.The Series SSS-1000 Lightweight Averaging Flow Sensors are not field repairable. If you wish to return a unit contact customer  service  to  receive  a  return  goods  authorization number before shipping.

Technical Specification:

ModelLength (Dimension A)
SSS-10023-5/32 ̋ (8.02 cm)
SSS-10035-13/32 ̋ (13.73 cm)
SSS-10047-21/32 ̋ (19.55 cm)
SSS-10059-29/32 ̋ (25.26 cm)
SSS-100612-1/2 ̋ (31.75 cm)
SSS-100714-3/4 ̋ (37.47 cm)
SSS-100817-1/8 ̋ (43.50 cm)
SSS-100919-13/32 ̋ (49.29 cm)
SSS-101021-21/32 ̋ (55.01 cm)
SSS-101123-29/32 ̋ (60.72 cm)

Duct Mounted Airflow Measurement Station

Rs 17,500/ Piece

Accuracy2%
ConditionNew

Duct Mounted Airflow Measurement Station

The SERIES FLST Airflow Measurement Station is easy to install — simply connect the tubing to the station fittings, then to a differential pressure manometer, gage, transmitter or switch. Single or multiple airflow elements are factory mounted and pre-piped in a casing designed for flanged connection to the duct work. Standard materials consist of a G90 galvanized casing and 6063-T5 anodized aluminum flow sensors, suitable for most HVAC applications.

The Series FLST utilizes an airflow averaging element in a head-type device, generating a differential (velocity) pressure signal similar to the orifice, venturi, and other had producing primary elements. Strategically located sensing ports continually sample the total and static pressures when inserted normal to flow.

Total pressure sensed by the upstream ports are continually averaged within the airflow element in an isolated chamber. The static sensing ports are averaged in a second isolation chamber. Multiple elements are joined together for connection to a differential measurement device (gage, transmitter, etc.) for flow measurement and indication purposes.

Features: 

  • Low signal-to-noise ratio
  • Factory mounted and pre-piped in a flanged duct section (casing)
  • Standard construction includes galvanized casing and 6063-T5 anodized aluminum flow sensors
  • Standard airflow stations can be operated (in air) continuously in temperatures up to 350°F or intermittently in temperatures up to 400°F


Options:

  • IM – Internal Pressure Connections.
  • F – (Oval Stations Only).

Application:

  • Building air intake and exhaust flow rate measurement
  • HVAC air flow measurement

 

FLST Specification Guide:

  • Provide where indicated and/or scheduled airflow traverse elements capable of continuously monitoring the fan or duct air volumes they serve.
  • Each element shall be designed and built to comply with, and provide results in accordance with, accepted practice for duct system traversing as
  • defined in the ASHRAE Handbook of Fundamentals, AMCA publication 203, as well as the Industrial Ventilation Handbook. The number of sens-
  • ing ports on each element, and the quantity of elements utilized at each installation, shall comply with ASHRAE Standard #111 for equal area duct
  • traversing.
  • Each airflow measuring element shall contain multiple total and static pressure sensing ports placed along the leading edge of the cylinder. The static pressure chamber shall incorporate dual offset static taps on opposing sides of the averaging chamber, so as to be insensitive to flow angle variations of as much as ±20 degrees in the approaching airstream.
  • The airflow traverse elements shall be capable of producing steady, non-pulsating signals of true total and static pressure, with an accuracy of 2% of actual flow for operating velocities as low as 100 feet per minute (fpm). Signal amplifying sensors requiring flow correction (K factors) for field calibration are not acceptable.
  • The airflow traverse elements shall not induce a measurable pressure drop, greater than 0.18 inch at 4,000 fpm. The units sound level within the duct shall not be amplified, nor shall additional sound be generated.
  • The probes shall be manifolded together in a 16 gauge galvanized steel duct section with 90 degree undrilled flanges, fabricated to the duct size, and shall contain multiple airflow traverse elements interconnected as here in before described.

Fume Hood Monitor

Rs 9,500 / Piece

BrandDWYER USA

Fume Hood Monitor

The MODEL AAFS Adjustable Air Flow Switch is capable of detecting a wide range of air velocities with minimal user calibration. Quality features include a stainless steel vane, galvanized steel base, and ABS enclosure.

Features:

  • Adjustable air flow sensitivity from 200 to 1800 FPM:


Installation:

  • Select a location in a horizontal duct at least 10 duct diameters from fans and 7 diameters from elbows, size changes, etc. which can cause turbulence. Also, avoid areas with excess vibration or where the temperature limits might be exceeded. Switch can be mounted in any horizontal duct.
  • Use vane as received for 8 ̋ (203 mm) or larger ducts. Trim for smaller ducts.
  • Cut a mounting hole and slot for the vane and drill four 3/32 ̋ (2.38 mm) screw holes. Insert switch through slot and rotate so arrow on switch enclosure points in direction of air flow. Attach switch to duct with sheet metal screws.
  • To make electrical connections, loosen the retaining screws and remove the conduit enclosure cover. See Figure 2. The SPDT snap switch has screw terminals marked common, normally open and normally closed. A ground screw is also provided. On decreasing flow, the normally open contacts will close and the normally closed contacts will open as the set point is passed.
  • To adjust set point, turn the flat-head screw located under the enclosure cover. Rotate clockwise to increase setting or counter-clockwise to decrease.
  • After all electrical connections and adjustments are complete, replace conduit enclosure cover.


Maintenance/Repair:
The only adjustment is that of the set point. Care should be taken to keep switch dry and free of dust, dirt and oil. No lubrication or routine maintenance is necessary in normal service.

Warranty/Return:
Refer to “Terms and Conditions of Sales” in our catalog and on our website. Contact customer service to receive a Return Goods Authorization number before shipping the product back for repair. Be sure to include a brief description of the problem plus any additional application notes

USB Wireless Receiver

Rs 900 / Piece

Model NumberDWYER USA
%
ConditionNew

USB Wireless Receiver

The SERIES USB-300 USB Wireless Receiver is a simple way to allow PC’s to test any EnOcean®-enabled device using wireless technology. This unit is equipped with a TCM 310 transceiver module, which provides bidirectional EnOcean® radio protocol. Radio messages are sent and received through a virtual series interface.

Features:

  • Works with any EnOcean®-enabled device
  • Compact USB design
  • Meets North American

 

Applications:

  • Building commissioning
  • Troubleshooting systems that incorporate EnOcean® communicating instruments
  • Product installation trials

 

Other Details:

ModelDescription
USB-300Wireless receiver, 868 MHz (required)
USB-300UWireless receiver, 902 MHz (required)

Temperature Transmitter

Rs 8,500 / Piece

BrandDWYER USA
%
ConditionNew

Carbon Dioxide and Temperature Transmitter

The SERIES CDT Carbon Dioxide and Temperature Transmitters accurately monitor the CO2 concentration and temperature in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength nondispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied* and unoccupied buildings against light source aging effects. The single beam dual wavelength sensor technology provides the highest level of accuracy compared to Automatic Baseline Correction methods which can unintentionally shift the calibration based on CO2 levels and barometric pressure conditions. In order to achieve a higher level of accuracy, the Series CDT includes digital barometric pressure adjustment and the ability to field-calibrate the sensor. For applications that require visual indication, the wall mount configurations of the Series CDT can be ordered with an integral LCD display. Push buttons are standard on all configurations of the transmitters for access to the menu structure, but wall mount configurations can be ordered without the buttons. To prevent tampering, the action of the buttons can be locked out using an internal dip switch selection.
For buildings occupied 24 hours per day, it is recommended that calibration be verified every 6 to 12 months depending on application.

Single beam dual-wavelength sensor advantages:

  • Automatically corrects for aging effects in occupied and unoccupied buildings. Perfect for hospitals and manufacturing plants that are occupied 24 hours per day
  • Measures actual unfiltered light intensity directly. Eliminates error from incorrect assumptions of gas concentration in theoretical logic assumption methods


Features:

  • Single beam dual wavelength NDIR sensor eliminates draft due to light source aging
  • Integral passive temperature outputs reduce number of devices mounted in the space
  • Service display tool available for models without an integral LED
  • Optional integral display and relay output


Application:

  • Demand control ventilation in schools, office buildings, hospitals, and other indoor environments
  • LEED ® certification

 

Technical Specification:

Range:CO2: 0 to 2000 or 0 to 5000 ppm (depending on model); Temperature: 32 to 122°F (0 to 50°C).
Accuracy:CO2: ±40 ppm ±3% of reading; Temperature: ± 1° C @ 25°.
Temperature:±1°C @ 25°C.
Temperature Dependence:±8 ppm/°C at 1100 ppm.
Non-Linearity:16 ppm.
Pressure Dependence:0.13% of reading per mm of Hg.
Response Time:2 min for 99% step change.
Output:Current: 4 to 20 mA (max 500 Ω); Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω), Relay: SPST NO 2 A @ 30 VDC;

Communicating Carbon Dioxide Detector

Rs 37,500 / Piece

ModelDWYER USA
%
Display TypeDigital

Communicating Carbon Dioxide Detector

The SERIES CDTA Communicating Carbon Dioxide Detector combines the function of three room sensors into a single, compact housing. Parameters include carbon dioxide, humidity, temperature, and temperature set point with override. By having field selectable Mtemperature set point with override. By having field selectable Modbus® and BACnet Communications, only four wires are needed for power and the communication signal. The communicating detectors can be daisy chained together to further reduce installation cost. In order to reduce the set up time, the RS-485 MAC address is set up using on board dip switches. A second set of dip switches are used to select whether output is Modbus® RTU or BACnet MS/TP communication protocols and to limit access to the set up menu. Like our Series CDT Carbon Dioxide Transmitter, the Series CDTA uses a Single Beam Dual Wavelength Non-Dispersive Infrared (NDIR) sensor to measure the carbon dioxide level. This technology can be used in installations that will be occupied 24 hours per day. For improved accuracy, the transmitter can be field calibrated to the environmental conditions of the installation. Also, the barometric pressure can be programmed to correct for altitude. The humidity uses a capacitive polymer sensor and the temperature is measured using a 10KO thermistor sensor. The humidity sensor is field replaceable without the need for additional calibration. Optional local and remote displays are available to display any of the parameters. For applications in which the building occupants aren’t familiar with CO2 concentrations, the LCD can be programmed to display temperature, humidity, or temperature set point instead.
Features:

Field selectable Modbus® and BACnet communications reduces wiringSingle-beam dual-wavelength CO2 sensorReplaceable humidity/temperature sensorPhysical hardware lockoutOptional remote display toolDigital Intelligent Temperature Compensation Algorithm (DITCA™) corrects for errors due to self heating effects of combination wall sensors
Application:

Demand control ventilation in schools, office buildings, hospitals, and other indoor environmentsLEED ® certificationRequestCallback

Carbon Dioxide Temperature Transmitter

Rs 8,500 / Piece

BrandDWYER USA

Carbon Dioxide Temperature Transmitter
The SERIES CDTR Carbon Dioxide, Relative Humidity and Temperature Transmitters reduce the number of sensors mounted on a wall or in a duct. By combining CO2, RH, and temperature in one device, system integrators are able to reduce installation time while lowering material cost at the same time. Like our popular Series CDT Carbon Dioxide Transmitter, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied* and unoccupied buildings against light source aging effects. In order to achieve the best possible accuracy, the Series CDTR also includes digital barometric pressure adjustment and the ability to field calibrate the sensor. Universal outputs for both carbon dioxide and relative humidity allow users to select the transmitter output to be 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC to work with virtually any building management controller. Additionally, passive thermistor or RTD sensor can be ordered for a temperature output. For applications that require visual indication, the wall mount configurations of the Series CDTR can be ordered with an integral LCD display. The display can be configured to display temperature only, relative humidity only, CO2 only, CO2 and humidity, or CO2 and temperature. Push buttons are standard on all configurations of the transmitters for access to the menu structure. To prevent tampering, the action of the buttons can be locked out using an internal jumper selection.

For buildings occupied 24 hours per day, it is recommended that calibration be verified every 6 to 12 months depending on application.

Features:

  • Digital Intelligence Temperature Compensation Algorithm (DITCA™) eliminates error due to the self heating effects of wall mount combination devices
  • Single beam dual wavelength NDIR CO2 sensor
  • Replaceable humidity/temperature sensors
  • Physical hardware lockout
  • Service display tool available for duct mount and wall mount units without an LCD
  • Relay output option


Application:

  • Demand control ventilation in schools, office buildings, hospitals, and other indoor environments
  • LEED ® certification

Carbon Monoxide Transmitter

Rs 7,000 / Piece

Model NumberDWYER USA
%
Measurement Range0 to 200 ppm.
Accuracy

+/-2% FS at the time of calibration.

Carbon Monoxide Transmitter

The SERIES CMT200, Carbon Monoxide Transmitter provides a field selectable current or voltage output that is proportional to the gas concentration in underground parking garages, vehicle maintenance facilities, or mechanical rooms. A field replaceable, electrochemical sensor provides accurate readings for up to 4 years with proper calibration. Field calibration can be done by using Model GCK-200CO-2000CO2 calibration gas, Model A-507A calibration adapter, and the on board span and zero potentiometers.

Model Available:

ModelDescription
CMT200Carbon Monoxide Transmitter, 0 to 200 PPM CO, 4 to 20 mA/2 to 10 VDC outputs.
CMT200-RCarbon Monoxide Transmitter, 0 to 200 PPM CO, 4 to 20 mA/2 to 10 VDC outputs, rectangular enclosure


Features:

  • Field selectable current or voltage outputs
  • Replaceable sensor
  • Field calibration kits


Application:

  • Garage ventilation
  • Mechanical room monitoring
  • BAS


The MODEL OSC-200 Omnidirectional Occupancy Sensor helps to automate building control systems. A spherical Fresnel lens provides a 360° detection zone with the use of infrared technology.

The MODEL OSW-100 Wall Mount Occupancy Sensor is an infrared sensor designed to  help  automate  building  control  systems.  The  Model  OSW-100  has  a  wide  110°  viewing angle to capture movement up to 49.2 ́ (15 m) away

Carbon Monoxide and Nitrogen Dioxide Gas Transmitter

Rs 20,000/ Piece

BrandDWYER USA

Carbon Monoxide and Nitrogen Dioxide Gas Transmitter

Model Available:

ModelDescription
GSTC-CCarbon Monoxide Transmitter with BACnet & Modbus Communication
GSTC-NNitrogen Dioxide Transmitter with BACnet & Modbus Communication
GSTC-C-LCDCarbon Monoxide Transmitter with BACnet & Modbus Communication with Integral LCD Display
GSTC-N-LCDNitrogen Dioxide Transmitter with BACnet & Modbus Communication with Integral LCD Display


The Series GSTC Carbon Monoxide/nitrogen Dioxide Gas Transmitter monitors the gas concentration in underground parking garages and loading docks. The carbon monoxide transmitter is used to measure the exhaust of gasoline engines, while the nitrogen dioxide transmitter is used for diesel engines. The Series GSTC is compatible with either BACnet or Modbus® communication protocol, allowing the transmitter to be used with almost any building management controller. The GSTC output is communicated over an RS-485 wire via BACnet or Modbus® communication protocol. To maximize the accuracy of the Series GSTC, the sensor can be field-calibrated using the A-449 remote LCD display. When the sensor reaches the end of its life, the display will indicate that the sensor needs to be replaced. BACnet and Modbus® communication protocol recommend limiting the number of nodes in any segment to 32. Therefore, the transceiver may be rated at one unit load. Fractional loads are also acceptable. The Series GSTC accounts as an eighth of a load on the MS/TP network.

Features:

  • Industrial grade replaceable CO or NO2 sensors
  • Field selectable BACnet or Modbus® communication on GSTC models
  • Integral LCD display option
  • Service display tool for set-up and calibration of models without a LCD


Applications:

  • Parking Garages
  • Loading Docks
  • Mechanical Room Monitoring

 

Technical Specification:

SensorField replaceable electrochemical, 4 years typical lifespan.
Span and Zero AdjustmentVia pushbutton, using optional A-449 display. Zero only via BACnet or MODBUS® communication protocol.
HousingUV resistant glass filled polycarbonate.
Output SignalsBACnet MS/TP, MODBUS® RTU, or MODBUS® ASCII (switch selectable) communication protocol.
lectrical Connection:Removable terminal block, knock outs for conduit fitting.
Calibration:Via pushbuttons using A-449 auxiliary display. Span gas concentration is field selectable.

Fume Hood Monitor

Rs 9,500 / Piece

BrandDWYER USA

Fume Hood Monitor

The MODEL 670 Fume Hood Monitor continuously senses air flow through the face of the fume hood, ensuring safe levels of fresh air are exhausting. The 670 provides a highly accurate hot wire sensor to detect very low flows common on fume hoods. The Model 670 comes with everything required to quickly install the unit including a mounting bracket, 24″ of tubing for connecting to the inside of the hood wall and a 120 Volt AC power adapter.

Features:

  • Flexible surface or flush mounting
  • LED safe and alarm status indicators
  • Audible alarm
  • Sash alarm input
  • Night set-back input


Specification:

  • Low Air Velocity Alarm Delay : Fixed 5 secs.
  • Visual LED Display : Red: Alarm; Green: Normal.
  • Horn Silence : Yes, temporary and permanent.
  • Accuracy : Face velocity ±10%.
  • Relay Output Low Air Flow Alarm :5 A @ 250 VAC.
  • Relay Input for Night Setback : 2 wire rated for 24 VDC usage.
  • Sash High Indication : Using a two wire micro switch or 3 wire proximity switch input, rated for 24 VDC usage.
  • Mounting : Semi flush, flush or surface mounted when using included bracket.


Applications:

  • Fume hood ventilation monitoring

Occupancy Sensor

Rs 3,500 / Piece

BrandDWYER USA

Occupancy Sensor

The Model OSC-200 Omnidirectional Occupancy Sensor automatically controls a HVAC ventilation system. A spherical Fresnel lens provides a 360° detection zone with the use of infrared technology. The integrated dual delay processor saves energy by eliminating false activation due to short-term occupancies. The Model OSC-200 is designed to be ceiling mounted, and is pre-wired for ease of installation.

Features:

  • Delay processor suppresses switch activation during momentary occupancy


Applications:

  • Lighting control
  • Building energy conservation


Install Base Unit:

  • Determine the location of the sensor according to the detection pattern shown in Figure 1a.
  • Remove the cover screw to open the sensor housing as shown in Figure 1b.
  • Remove the circuit board by bending the tab outward (Figure 1b.)
  • Screw the base of the sensor housing to the ceiling through the knockout holes

 

Wiring:
Model OSC-200 is pre-wired for ease of use with 22AWG colored wires. Connect the wires as showin in figure 2

Walk Test:
Before beginning test, make certain that the On and Off Delay jumpers (located on the circuit board) are connected in the “A” positions as shown in Figure 3. If they are not, follow the procedure under the section titled On/Off Delay Settings to rearrange the jumpers to location “A.” Replace the sensor housing and tighten screw.

Storage And Cleaning:
The sensor lens is the most delicate part of the Occupancy Sensor. The lens should be kept clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allow the lens to fully dry before using the sensor. The sensor should be installed or stored in an area of room temperature between -4 and 140ºF (-20 to 60ºC).

Maintenance:
After final installation of the unit, no routine maintenance is required. The Model OSC-200 is not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty). Be sure to include a brief description of the problem plus any relevant application notes. Contact customer service to receive a return goods authorization number before shipping.

Wall Mount Occupancy Sensor

Rs 9,500 / Piece

Range49.2 ft (15 m).
Weight G3.2 oz (90.7 g).
BrandDWYER USA

Wall Mount Occupancy Sensor

The Model OSW-100 Wall Mount Occupancy Sensor is an infrared sensor designed to automatically control an HVAC ventilation system. A unique dual delay processor eliminates false triggers due to short-term occupancies.

Other Details:
Install Base Unit

  • Determine the location of the sensor according to the detection pattern shown in Figure 1.
  • Screw the base of the mounting bracket to the desired position on the wall as shown in Figure 2.
  • Feed the cable through the hole on the back of the bracket.
  • Loosen the screw on the bottom of the sensor and remove the cover.
  • Feed the cable through the center hole on the back of the sensor housing.
  • Attach the sensor to the mounting bracket.


Wiring:

  • Turn the screw for each terminal counterclockwise.
  • Connect the cable to the corresponding terminals as shown in Figure 3


Walk test:
Before beginning test, make certain that the On and Off delay jumpers (located on the circuit board) are connected in the “A” positions as shown in Figure 4. If they are not, follow the procedure under the section titled On/Off Delay Settings torearrange the jumpers to location “A.” Replace the sensor housing and tighten screw.

Storage And Cleaning:
The sensor lens is the most delicate part of the Occupancy Sensor. The lens should be kept clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allow the lens to fully dry before using the sensor.  

Maintenance:
After final installation of the unit, no routine maintenance is required. The Model OSW-100 is not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty). Be sure to include a brief description of the problem plus any relevant application notes. Contact customer service to receive a return goods authorization number before shipping. Request

Elementor #1032

Differential Pressure Gauge

Rs 2,800 / Piece

BrandAerosense
Accuracy2% of FS
Brand
ConditionNew
Usage/ApplicationFilter monitoring
Size4 inches
Ambient Temperature-20 to 60 degree C
ConnectionNew
TypeDifferential Pressure Gauge
Dial4 inches
Case materialDie cast Aluminium
Diaphragm positionVertical

Differential Pressure Gauge

CE approved Differential Pressure Gage with adjustable bookmarks feature indicates Positive, Negative or Differential pressure.

Applications:

  • Filter monitoring
  • Blower vacuum monitoring
  • Fan pressure indication
  • Duct, room or building pressures
  • Clean room positive pressure indication

Aerosense Differential Pressure Gauge

Rs 2,800 / Piece

BrandIntegerated Engineers India

Aerosense Differential Pressure Gauge

Backed by years of experience of this domain, we present clients with the premium quality of Aerosense Differential Pressure Gage. Used for measurement of differential pressure, the pressure gauge is manufactured by using latest technology. In order to ensure high standards of quality, the Aerosense differential pressure gauge is procured from trusted vendors.
Features:
Excellent measurement accuracy Easy to use Requires less maintenance
Specifications:Indicating Pressure Reference: Differential Pressure Gauge Ambient Temp.Range: -7 ~ 60 °c Weight: 1 Lb. 2oz (510g)

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)

Aerosense DP Gauge

 

Rs 3,500 / Piece

BrandAerosense

Aerosense DP Gauge

Aerosense DP Gauge
 are extensively used for measuring the differential pressure in pharma clean rooms, HVAC applications, pharmaceutical machinery,Pass Box,etc.

Specifications:

  • Indicating Pressure Reference: Gp,Cp,Ap or Dp Selectable
  • Function: Electric Signal-controlled
  • Application: Industrial
  • Display: Digital



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)

Aerosense Differential Pressure Indicator

Rs 9,500  / Piece

BrandAerosense
ApplicationIndustrial, Laboratory

Aerosense Differential Pressure Indicator

Aerosense Differential Pressure Indicator
 is demanded for its impeccable qualities and features. It is extensively demanded in the applications areas where HVAC systems are installed to resolve the problem of humidity temperature control. It is suitable for energy optimization and therefore widely used for the measurement of HVAC duct pressure. Along with the precised operations it has integrated high speed differential pressure sensor that provide accurate results in a significant manner.

Features:

  • Integrated red LED seven segment display
  • Differential pressure sensor
  • Stainless steel at the back

Specifications:

  • Case Material: 304 Stainless Steel
  • Measure Range: 0-160MPa -0.1-0-2.4MPa
  • Size: 100mm/4″(From 40mm~250mm)

 



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)

Aerosense Differential Pressure Switch

Rs 18,500 / Piece

Current Rating (In Amps)Aerosense,Galaxy,Omicron,Sensocon,Dwyer

Aerosense Differential Pressure Switch

The series of pressure switches Aerosense Differential Pressure Switch is the most updated one.Generally, they are applied in the fan, blower and filter monitoring as well as to measure the pressure and flow of gases liquids in different industries. Enabled with the effective mechanism these switches have high-tech features specifications such as selectable switching point adjustment and measurement unit facility in PA.Several additional accessories are also provided for the ease of users that primarily include metallic duct connectors,plastic dust connectors, and fixing screws.

Features:

  • Pressure and flow monitoring
  • Two fixing screws
  • Metallic duct connectors

Specifications:

  • Medium: Air, Non-Combustible and Non-Aggressive Gasses
  • Electrical Rating: 1.5A (0.4A) / 250V
  • Usage: Control Switch



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)

Aerosense Differential Pressure Cum Flow Transmitter

 

Rs 18,500  / Piece

BrandIntegerated Engineers India
ModelAerosense

Aerosense Differential Pressure cum Flow Transmitter

Aerosense Differential Pressure cum Flow Transmitter is technically engineered type of flow transmitter that is especially used in HVAC/R industry to control the flow, velocity and static of air pressure. Apart from measuring the flow of air control, this type of transmitter is used in the other major applications such as VAV domain and air flow monitoring across centrifugal fans blowers. It supports low power consumption as well as enabled with the zero point calibration system.

Features:

  • VAV applications
  • Minimum resistance
  • Piezo resistive

Specifications:

  • Pressure range: 0.001MPa 35MPa
  • Medium: Liquid,Gas and Steam
  • Temperature: -20-120c

 



Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)

Aerosense Series CDT-100-RLY Carbon Dioxide Transmitter

Rs 18,500/ Piece

UsageDemand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
BrandAEROSENSE
Size123mmX70mmX43mm
Re Calibration function10 minutes manual recalibration is executable with TRB 100 tool
Response time150 seconds
Sampling interval3 sec

Aerosense Series CDT-100-RLY Carbon Dioxide Transmitter

Series CDT-100-RLY Carbon Dioxide Transmitter

Series CDT-100-RLY, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements.

Measurement range 2000 ppm (5000/10000 ppm) selectable by jumper. It gives analog and Relay output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (6-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • Models available with SPST (Single Pole, Single Throw, normally open) relay output.
  • Re-Calibration function: 10 minutes’ manual recalibration is executable with TRB-100 tool
  • Size: 123mmX70mmX43mm
  • Operating Temperature:-10 to 60˚C
  • Operating Humidity range: 0 to 95% RH
  • Storage temperature: -30 to 70˚C
  • Storage temperature for cold storage: -40 to 70˚C
  • Measurement range: 0 to 2000 ppm (5000/10000 ppm is settable with jumper)
  • Accuracy: ±30ppm ±3%
  • Response time: 150 seconds
  • Sampling interval: 3 sec

ELECTRICAL DATA

  • Input power: 24VAC ±20%, 50/60 Hz or 24VDC (12-36 VDC)
Model No.Specifications
CDT-100-RLYCarbon Dioxide Transmitter with relay output
CDT-100-RLY-LCDCarbon Dioxide Transmitter with relay output & display



Additional Information:

  • Item Code: CDT-100

Aerosense Series CDT-300 Carbon Dioxide Transmitter

Rs 18,500/ Piece

Display TypeDigital
ModelSeries CDT 300
Place Of Origindelhi
Re Calibration function10 minutes manual recalibration is executable with TRB 100 tool
Response time150 seconds
ApplicationDemand Control Ventilation in schools,office buildings,hospitals and other indoor environments

Aerosense Series CDT-300 Carbon Dioxide Transmitter

Series CDT-300 Carbon Dioxide Transmitter

Series CDT-300, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements.

Measurement range upto 70000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch
  • Power: 24VDC, AC
  • Size: 123mmX70mmX43mm
  • Power: 24VDC ±20% (3-wired)
  • Operating Temperature:-10 to 60˚C
  • Operating Humidity range: 0 to 95% RH
  • Storage temperature: -30 to 70˚C
  • Storage temperature for cold storage: -40 to 70˚C
  • Measurement range:0 to 2000/ 3000/ 5000/ 10000/ 20000/50000/ 70000 ppm (Jumper selectable)
  • Accuracy: ±30ppm ±3%
  • Response time: 150 seconds
  • Response time for cold storage: 70 seconds
  • Sampling interval: 3 sec
Model No.Specifications
CDT-300Carbon Dioxide Transmitter
CDT-300-LCDCarbon Dioxide Transmitter with display

ASG-02 Aerosense Differential Pressure Gauge Range 0-2.0 Inch WC

ASG-02 Aerosense Differential Pressure Gauge Range 0-2.0 Inch WCSeries ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication
 
 

ASG-03 Aerosense Differential PressureGauge Range 0-3.0 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-3.0 INCH WC
UseBlower Vacuum Monitoring
Display TypeAnalog
Pressure TypeDifferential Pressure
Accuracy+-2%
Model NumberASG-03
Weight510 g
MountingDiaphragm in vertical position. Consult factory for other position orientations.
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)

ASG-03 Aerosense Differential Pressure Gauge Range 0-3.0 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-150 Aerosense Differential Pressure Gauge Range 0-150 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-150 INCH WC
UseDuct Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g


ASG-150 Aerosense Differential Pressure Gauge Range 0-150 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-06 Aerosense Differential Pressure Gauge Range 0-6.0 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0 to 6.0 inch of WC
UseDuct
Display TypeAnalog
Pressure TypeDifferential Pressure
Accuracy+-2%
Model NumberASG-06
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-06 Aerosense Differential Pressure Gauge Range 0-6.0 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-00 Aerosense Differential Pressure Gauge Range 0-.25 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-.25 Inch WC
UseClean Room Positive Pressure Indication
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Model NumberASG-00+-
Weight510 g
MountingDiaphragm in vertical position. Consult factory for other position orientations.


ASG-00 Aerosense Differential Pressure Gauge Range 0-.25 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-12 Aerosense Differential Pressure Gauge Range 0-12 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
Pressure Range0-12 INCH WC
UseBuilding Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-12 Aerosense Differential Pressure Gauge Range 0-12 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-30 Aerosense Differential Pressure Gauge Range 0-30 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-30 INCH WC
UseBuilding Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-30 Aerosense Differential Pressure Gauge Range 0-30 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-25 Aerosense Differential Pressure Gauge Range 0-25 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
Pressure Range0-25 INCH WC
UseBuilding Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-25 Aerosense Differential Pressure Gauge Range 0-25 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-40 Aerosense Differential Pressure Gauge Range 0-40 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-40 INCH WC
UseBuildings
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-40 Aerosense Differential Pressure Gauge Range 0-40 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-80 Aerosense Differential Pressure Gauge Range 0-80 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
Pressure Range0-80 INCH WC
UseDucts
Display TypeAnalog
Pressure TypeDifferential Pressure
Accuracy+-2%
Weight510 g
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-80 Aerosense Differential Pressure Gauge Range 0-80 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-50 Aerosense Differential Pressure Gauge Range 0-50 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-50 INCH WC
UseBuildings
Display TypeAnalog
Pressure TypeDifferential Pressure
Accuracy+-2%
Weight510 g
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-50 Aerosense Differential Pressure Gauge Range 0-50 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-60 Aerosense Differential Pressure Gauge Range 0-60 Inch WC

 
Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0 to 60 INCH WC
UseBuildings
Display TypeAnalog
Pressure TypeDifferential Pressure
Accuracy+-2%
Weight510 g
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-60 Aerosense Differential Pressure Gauge Range 0-60 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-180 Aerosense Differential Pressure Gauge Range 0-180 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-180 INCH WC
UseDuct Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar


ASG-180 Aerosense Differential Pressure Gauge Range 0-180 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-100 Aerosense Differential Pressure Gauge Range 0-100 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
Pressure Range0-100 INCH WC
UseDuct Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-100 Aerosense Differential Pressure Gauge Range 0-100 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-120 Aerosense Differential Pressure Gauge Range 0-120 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-120 INCH WC
UseDuct Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-120 Aerosense Differential Pressure Gauge Range 0-120 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-201 Aerosense Differential Pressure Gauge Range 0-1 PSI

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
Pressure Range0 to 1 PSI
UseDuct Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-201 Aerosense Differential Pressure Gauge Range 0-1 PSI Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-250 Aerosense Differential Pressure Gauge Range 0-250 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0 to 250 INCH WC
UseDuct Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar))


ASG-250 Aerosense Differential Pressure Gauge Range 0-250 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-05 Aerosense Differential Pressure Gauge Range 0-5.0 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-5.0 INCH WC
UseClean Rooms
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-05 Aerosense Differential Pressure Gauge Range 0-5.0 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-04 Aerosense Differential Pressure Gauge Range 0-4.0 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-4.0 INCH WC
UseRoom pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-04 Aerosense Differential Pressure Gauge Range 0-4.0 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-10 Aerosense Differential Pressure Gauge Range 0-10 Inch WC

Minimum Order Quantity1 Number
Model NumberASG-10
Usage/ApplicationDuct,Room or Building Pressures
Measuring Range0-10 INCH WC
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
MountingDiaphragm in vertical position. Consult factory for other position orientations.
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-10 Aerosense Differential Pressure Gauge Range 0-10 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-08 Aerosense Differential Pressure Gauge Range 0-8.0 Inch WC

 

 

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-8.0 INCH WC
UseBuilding Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
Weight510 g
MountingDiaphragm in vertical position. Consult factory for other position orientations.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-08 Aerosense Differential Pressure Gauge Range 0-8.0 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-07 Aerosense Differential Pressure Gauge Range 0-7.0 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0 to 7.0 inch of WC
UseDuct Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Accuracy+-2%
Weight510 g
MountingDiaphragm in vertical position. Consult factory for other position orientations.
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-07 Aerosense Differential Pressure Gauge Range 0-7.0 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-20 Aerosense Differential Pressure Gauge Range 0-20 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-20 INCH WC
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-20 Aerosense Differential Pressure Gauge Range 0-20 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-15 Aerosense Differential Pressure Gauge Range 0-15 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-15 INCH WC
UseBuilding Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
MountingDiaphragm in vertical position. Consult factory for other position orientations.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-15 Aerosense Differential Pressure Gauge Range 0-15 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-O Aerosense Differential Pressure Gauge Range 0-.50 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-.50 INCH WC
UseBuilding Pressure
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Accuracy+-2%
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-O Aerosense Differential Pressure Gauge Range 0-.50 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential. 

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-Ol Aerosense Differential Pressure Gauge Range 0-1.0 Inch WC

Minimum Order Quantity1 Number
Dial Size4 inch / 100 mm
BrandAerosense
Pressure Range0-1.0 INCH WC
UseFan Pressure Indication
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Weight510 g
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-Ol Aerosense Differential Pressure Gauge Range 0-1.0 Inch WC Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

Aerosense Differential Pressure Indicator Transmitter

Minimum Order Quantity1 Number
Accuracy+1-0.5%
BrandAerosense
Input Pressure (Pascal)-100 to +103 Pascal’-250 to +250 Pascal
Connection2 Nos.
MediumAir or Gases (Non Corrosive)
Resolution1 P3scal/0.1 mm w.c
Power24 Volts D.C.
DisplayIntegrated 4 Digit Red LED 7
Maximum Over Pressure2 Times the rated pressure
Size75x70x40 mm


Aerosense Differential Pressure Indicator Transmitter Series CDPI/ADPI Differential Pressure Indicator/ Transmitter with circular standard Differential Pressure Gage cut out & 0.5% accuracy of F.S

Product Applications:

  • Pharma Cleanrooms
  • HVAC
  • Environmental
  • Pharma Machinery
  • Across filters
  • Hospital violation rooms
  • Operation theatres & laboratories
  • Precision of measurement in HVAC duct pressure application makes the instrument suitable for optimization of energy & thereby its conversation is ventilation systems.
  • Built in High and Low Buzzer Alarm for process set parameter.
  • Violation with Acknowledgment key.
  • Integrated 4 Digit Red LED 7 segment display of standard 0.5″ size.
  • Analog output & RS-485 communication lead to easy integration with variable frequency drives & SCADA/BMS systems, AHUs.


Pressure Measuring Range:

  • -10.0 to +10.0 mm.W.C./-25.0 to +25.0 mm. W.C.
  • -50.0 to -50.0 mm.W.C./0.0 to+100.0 mm. W.C.
  • -100 to +103 Pascal’-250 to +250 Pascal
  • Built In High & Low Buzzer Alarm for Process Set Parameter
  • Violation with Acknowledgment Key
  • ADPI- Instrument Encbsure
  • CDPI-Standard 114.50
  • Unit Selection: mm.W.CiPascal selectable from front key
  • Segment Display 0.5″ High
  • Sensor: Integrated High Speed Differential Pressure Sensor
  • Output (Optional): 4-20 mAIsolated.’ 0-10VDC
  • Communication Optional: Isolated RS485 Modbus Protocol
  • MOC: ADPI-W.S. Powder Coated Body with Stairless Steel Front Flush Plate for Modular Wall Fitment in Clean Rooms : CDPI-Aluminum Powder-Coated Body with Flush Bezel. Splash-Proof Polycarbonate Front Cladding

Aerosense Series ASG Differential Pressure Gage

Minimum Order Quantity1 Number
Model NumberSeries ASG
Usage/ApplicationBlower Vacuum Monitoring
Measuring Range0-50 MM WC
BrandAerosense
Accuracy+-2%
Weight510 g
Size101.6 mm
Mounting Of GaugeDiaphragm in vertical position. Consult factory for other position orientations.
Warranty1 Year
Battery IncludedNo


Aerosense Series ASG Differential Pressure Gage Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

Aerosense Digital Differential Pressure Gauge

Minimum Order Quantity1 Number
Display TypeRed LED 7 segment Display
BrandAerosense
Model No.CDPI Digital
Accuracy0.5%
Scale Range4 digit
Dial Size (Millimetre)0.5 inch


Aerosense Digital Differential Pressure Gauge Aerosense Differential Pressure Indicator/Transmitter with circular standard Differential Pressure Gage cut out.

Features:

  • Built-in High and Low Buzzer Alarm for process set parameter
  • Violation with Acknowledgment key
  • Unit selectable in mm WC /Pascal


Applications:

  • Pharma Cleanrooms
  • HVAC
  • Environmental
  • Pharma Machinery
  • Across filters
  • Hospital violation rooms
  • Operation theaters & laboratories


Advantages:

  • Precision of measurement in HVAC duct pressure application makes this instrument suitable for optimization of energy & thereby its conversation is ventilation systems
  • Analog Output & RS-485 Communication lead to easy integration with Variable frequency drives & SCADA/BMS systems, AHUs.

ASG-202 Aerosense Differential Pressure Gauge Range 0-2 PSI

Minimum Order Quantity1 Number
Model NumberASG-202
Usage/ApplicationDuct,Room or Building Pressures
Measuring Range0-2 PSI
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
Over PressureRelief plug opens at approximately 25 psig (1.72 bar)
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-202 Aerosense Differential Pressure Gauge Range 0-2 PSI Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-203 Aerosense Differential Pressure Gauge Range 0-3 PSI

 

Minimum Order Quantity1 Number
Model NumberASG-203
Usage/ApplicationFilter Monitoring
Measuring Range0-3 PSI
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Over PressureRelief plug opens at approximately 25 psig (1.72 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-203 Aerosense Differential Pressure Gauge Range 0-3 PSI Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-204 Aerosense Differential Pressure Gauge Range 0-4 PSI

Minimum Order Quantity1 Number
Model NumberASG-204
Usage/ApplicationClean Room Positive Pressure Indication
Measuring Range0-4 PSI
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT duplicate high and low pressure taps
Over PressureRelief plug opens at approximately 25 psig (1.72 bar)
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-204 Aerosense Differential Pressure Gauge Range 0-4 PSI Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-205 Aerosense Differential Pressure Gauge Range 0-5 PSI
Minimum Order Quantity1 Number
Model NumberASG-205
Usage/ApplicationFan Pressure Indication
Measuring Range0-5 PSI
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
BrandAerosense
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-205 Aerosense Differential Pressure Gauge Range 0-5 PSI Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-210 Aerosense Differential Pressure Gauge Range 0-10 PSI

Minimum Order Quantity1 Number
Model NumberASG-210
Usage/ApplicationClean Room Positive Pressure Indication
Measuring Range0-10 PSI
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-210 Aerosense Differential Pressure Gauge Range 0-10 PSI Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-215 Aerosense Differential Pressure Gauge Range 0-15 PSI

Minimum Order Quantity1 Number
Model NumberASG-215
Usage/ApplicationFilter Monitoring
Measuring Range0-15 PSI
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)

ASG-215 Aerosense Differential Pressure Gauge Range 0-15 PSI Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-220 Aerosense Differential Pressure Gauge Range 0-20 PSI

Minimum Order Quantity1 Number
Model NumberASG-220
Usage/ApplicationFan Pressure Indication
Measuring Range0-20 PSI
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-220 Aerosense Differential Pressure Gauge Range 0-20 PSI Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-230 Aerosense Differential Pressure Gauge Range 0-30 PSI

Minimum Order Quantity1 Number
Model NumberASG-230
Usage/ApplicationDuct,Room or Building Pressures
Measuring Range0-30 PSI
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-230 Aerosense Differential Pressure Gauge Range 0-30 PSI Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-6MM Aerosense Differential Pressure Gauge Range 6 MM

Minimum Order Quantity1 Number
Model NumberASG-6MM
Usage/ApplicationClean Room Positive Pressure Indication
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-6MM Aerosense Differential Pressure Gauge Range 6 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-10MM Aerosense Differential Pressure Gauge Range 10 MM

Minimum Order Quantity1 Number
Model NumberASG-10MM
Usage/ApplicationDuct,Room or Building Pressures
Measuring Range10 MM
BrandAerosense
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-10MM Aerosense Differential Pressure Gauge Range 10 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-15MM Aerosense Differential Pressure Gauge Range 15 MM

Minimum Order Quantity1 Number
Model NumberASG-15MM
Usage/ApplicationFan Pressure Indication
Measuring Range15 MM
BrandAerosense
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Temperature Limits20 to 140″F*(-6.67 to 60’C)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-15MM Aerosense Differential Pressure Gauge Range 15 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-25MM Aerosense Differential Pressure Gauge Range 25 MM

Minimum Order Quantity1 Number
Model NumberASG-25MM
Usage/ApplicationClean Room Positive Pressure Indication
BrandAerosense
Measuring Range25 MM
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-25MM Aerosense Differential Pressure Gauge Range 25 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-30MM Aerosense Differential Pressure Gauge Range 30 MM

Minimum Order Quantity1 Number
Model NumberASG-30MM
Usage/ApplicationFan Pressure Indication
Measuring Range30 MM
BrandAerosense
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-30MM Aerosense Differential Pressure Gauge Range 30 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-50MM Aerosense Differential Pressure Gauge Range 50 MM

Minimum Order Quantity1 Number
BrandAerosense
Model Name/NumberASG-50MM
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Pressure Gauge Range50 mm
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-50MM Aerosense Differential Pressure Gauge Range 50 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-80MM Aerosense Differential Pressure Gauge Range 80 MM

Minimum Order Quantity1 Number
Model NumberASG-80MM
Usage/ApplicationClean Room Positive Pressure Indication
Measuring Range80 MM
BrandAerosense
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar


ASG-80MM Aerosense Differential Pressure Gauge Range 80 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-100MM Aerosense Differential Pressure Gauge Range 100 MM

Minimum Order Quantity1 Number
Model NumberASG-100MM
Usage/ApplicationDuct,Room or Building Pressures
MaterialPlastic
Measuring Range100 MM
BrandAerosense
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT duplicate high and low pressure tap
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-100MM Aerosense Differential Pressure Gauge Range 100 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-125MM Aerosense Differential Pressure Gauge Range 125 MM

Minimum Order Quantity1 Number
Model NumberASG-125MM
Usage/ApplicationFan Pressure Indication
MaterialPlastic
Measuring Range125 MM
BrandAerosense
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-125MM Aerosense Differential Pressure Gauge Range 125 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-150MM Aerosense Differential Pressure Gauge Range 150 MM

Minimum Order Quantity1 Number
Model NumberASG-150MM
Usage/ApplicationFilter Monitoring
MaterialPlastic
Measuring Range150 MM
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


ASG-150MM Aerosense Differential Pressure Gauge Range 150 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential. 

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-200MM Aerosense Differential Pressure Gauge Range 200 MM

Minimum Order Quantity1 Number
Model NumberASG-200MM
Usage/ApplicationFan Pressure Indication
BrandAerosense
Measuring Range200 MM
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-200MM Aerosense Differential Pressure Gauge Range 200 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-250MM Aerosense Differential Pressure Gauge Range 250 MM

Minimum Order Quantity1 Number
Model NumberASG-250MM
Usage/ApplicationFan Pressure Indication
MaterialPlastic
Measuring Range250 MM
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
MountingDiaphragm in vertical position. Consult factory for other position orientations.
Process Connections1/8″ female NPT duplicate high and low pressure taps
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-250MM Aerosense Differential Pressure Gauge Range 250 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-300MM Aerosense Differential Pressure Gauge Range 300 MM

Minimum Order Quantity1 Number
Model NumberASG-300MM
Usage/ApplicationDuct,Room or Building Pressures
MaterialPlastic
Measuring Range300 MM
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT duplicate high and low pressure taps


 ASG-300MM Aerosense Differential Pressure Gauge Range 300 MM Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-0.5KPA Aerosense Differential Pressure Gauge Range 0-0.5 KPA

Minimum Order Quantity1 Number
Model NumberASG-0.5KPA
Usage/ApplicationFilter Monitoring
Measuring Range0-0.5 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT

 

ASG-0.5KPA Aerosense Differential Pressure Gauge Range 0-0.5 KPA with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.


Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-1KPA Aerosense Differential Pressure Gauge Range 0-1 KPA

Minimum Order Quantity1 Number
Model NumberASG-1KPA
Usage/ApplicationDuct,Room or Building Pressures
Measuring Range0-1 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT

 

ASG-1KPA  Aerosense Differential Pressure Gauge Range 0-1 KPA with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-1.5KPA Aerosense Differential Pressure Gauge Range 0-1.5 KPA

Minimum Order Quantity1 Number
BrandAerosense
Measuring Range0-1.5 KPA
Model NumberASG-1.5KPA
Usage/ApplicationDuct,Room or Building Pressures
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT


ASG-1.5KPA Aerosense Differential Pressure Gauge Range 0-1.5 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-2KPA Aerosense Differential Pressure Gauge Range 0-2 KPA

Minimum Order Quantity1 Number
BrandAerosense
Measuring Range0-2 KPA
Model NumberASG-2KPA
Usage/ApplicationDuct,Room or Building Pressures
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT


ASG-2KPA Aerosense Differential Pressure Gauge Range 0-2 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-2.5KPA Aerosense Differential Pressure Gauge Range 0-2.5 KPA

Minimum Order Quantity1 Number
Model NumberASG-2.5KPA
Usage/ApplicationClean Room Positive Pressure Indication
Measuring Range0-2.5 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT


ASG-2.5KPA Aerosense Differential Pressure Gauge Range 0-2.5 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-3KPA Aerosense Differential Pressure Gauge Range 0-3 KPA

Minimum Order Quantity1 Number
Model NumberASG-3KPA
Usage/ApplicationDuct,Room or Building Pressures
Measuring Range0-3 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Process Connections1/8″ female NPT
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-3KPA Aerosense Differential Pressure Gauge Range 0-3 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-4KPA Aerosense Differential Pressure Gauge Range 0-4 KPA

Minimum Order Quantity1 Number
Model NumberASG-4KPA
Usage/ApplicationFan Pressure Indication
Measuring Range0-4 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Process Connections1/8″ female NPT
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-4KPA Aerosense Differential Pressure Gauge Range 0-4 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-5KPA Aerosense Differential Pressure Gauge Range 0-5 KPA

Minimum Order Quantity1 Number
Model NumberASG-5KPA
Usage/ApplicationFilter Monitoring
Measuring Range0-5 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT

ASG-5KPA Aerosense Differential Pressure Gauge Range 0-5 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:
  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication
 

ASG-8KPA Aerosense Differential Pressure Gauge Range 0-8 KPA

Minimum Order Quantity1 Number
Model NumberASG-8KPA
Usage/ApplicationClean Room Positive Pressure Indication
Measuring Range0-8 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)
Process Connections1/8″ female NPT


ASG-8KPA Aerosense Differential Pressure Gauge Range 0-8 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-10KPA Aerosense Differential Pressure Gauge Range 0-10 KPA

Minimum Order Quantity1 Number
Model NumberASG-10KPA
Usage/ApplicationBlower Vacuum Monitoring
Measuring Range0-10 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Process Connections1/8″ female NPT
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-10KPA Aerosense Differential Pressure Gauge Range 0-10 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-15KPA Aerosense Differential Pressure Gauge Range 0-15 KPA

Minimum Order Quantity1 Number
Model NumberASG-15KPA
Usage/ApplicationDuct,Room or Building Pressures
Measuring Range0-15 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Process Connections1/8″ female NPT

 

ASG-15KPA Aerosense Differential Pressure Gauge Range 0-15 KPA with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-20KPA Aerosense Differential Pressure Gauge Range 0-20 KPA

Minimum Order Quantity1 Number
Model NumberASG-20KPA
Usage/ApplicationDuct,Room or Building Pressures
Measuring Range0-20 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Process Connections1/8″ female NPT


ASG-20KPA Aerosense Differential Pressure Gauge Range 0-20 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-25KPA Aerosense Differential Pressure Gauge Range 0-25 KPA

Minimum Order Quantity1 Number
Model NumberASG-25KPA
Usage/ApplicationBlower Vacuum Monitoring
Measuring Range0-25 KPA
BrandAerosense
Accuracy+-2%
Weight510 g
Size4″ (101.6 mm) diameter dial face.
Process Connections1/8″ female NPT


ASG-25KPA Aerosense Differential Pressure Gauge Range 0-25 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

ASG-30KPA Aerosense Differential Pressure Gauge Range 0-30 KPA

Minimum Order Quantity1 Number
Model NumberASG-30KPA
Usage/ApplicationFilter Monitoring
Measuring Range0-30 KPA
BrandAerosense
Accuracy+-2%
Weight1 lb 2 oz (510 g),MP 6 HP 2 lb 2 oz (963 g)
Size4″ (101.6 mm) diameter dial face
Process Connections1/8″ female NPT
Pressure Limits-20 in Hg to 15 psig (-0.677 bar to 1.034 bar)


ASG-30KPA Aerosense Differential Pressure Gauge Range 0-30 KPA Series ASG Differential Pressure Gage with adjustable bookmarks. Indicates Positive, Negative or Differential Pressure. Series ASG Differential Pressure Gage with additional bookmark feature and a wide choice of ranges and models. It quickly indicates Air & non-combustible and compatible gases pressure – either positive, negative or differential.

Product Applications:

  • Filter monitoring
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

Aerosense mack digital-pressure gauge wholesaler

Differential Pressure Indicator

Rs 9,500 / Piece

Model NumberADPI
BrandAerosense
ApplicationIndustrial
Usage/ApplicationPharma Cleanrooms
ConnectionNew
Scale Range4 digits
Accuracy0.5%
Application/UsageHVAC
Display TypeRed LED 7 segment Display
ConditionNew
Modbus communicationRS-485
Output range4-20mA

Differential Pressure Indicator

Our firm offers a high-quality range of Aerosense Differential Pressure Indicator/Transmitter.

Features:

  • Panel mount/Rectangular type cut out
  • Built in High and Low Buzzer Alarm for process set parameter
  • Violation with Acknowledgement key


Applications:

  • Pharma Cleanrooms
  • HVAC
  • Environmental
  • Pharma Machinery
  • Across Filters
  • Hospital Violation Rooms
  • Operation Theaters & Laboratories


Advantages:

  • Precision of measurement in HVAC duct pressure application makes this instrument suitable for optimization of energy & thereby its conversation is ventilation systems
  • Analog Output & RS-485 Communication lead to easy integration with Variable frequency drives & SCADA/BMS



Additional Information:

  • Item Code: ADPI

Aerosense Differential Pressure Switch

Rs 1,350 / Piece

Power/Voltage0.11 A/250 VAC
Usage/ApplicationFan, Blower and filter monitoring
BrandAEROSENSE
Use ForGas
ConditionNew
Media TypeGas
Ambient Temperature-20 to 60 degree C
ModelPS-200
ApplicationsPressure and Flow monitoring
Product ApplicationsValve and damper monitoring

Aerosense Differential Pressure Switch

Series PS Differential Pressure Switch With dual scale field adjustable Set Point Knob

The Series PS Differential Pressure Switch is designed for pressure, vacuum and differential pressure. The dual scaled adjustment knob allows changes to the switching pressure to be made without a pressure gage. The PS is available in settings from 20 Pa to 4500 Pa. The compact size, adjustment knob and low cost make the PS the perfect choice for HVAC applications.

Product Applications:

  • Fan, Blower and filter monitoring
  • Pressure and Flow monitoring
  • Valve and damper monitoring

Technical Data

  • Service: Air & non aggressive gases
  • Material: ABS
  • Electrical Connection: 3 Screw terminal
  • Cable Entry: M16
  • Pressure Connection: Male 0 5 MM
  • Weight: 150 gms
  • Operation Temperature: -20 to 60° C
  • Storage Temperature: -40 to 85° C
  • Maximum Pressure: 50 kPA
  • IP Protection: IP54

Optional Accessories

  • 2 Fixing Screws
  • 2 Plastic duct connectors
  • 2 m tube 0 4/7 mm
  • Metallic duct connectors



Additional Information:

  • Item Code: PS-200

Aerosense Series CMT-100 Carbon Monoxide Transmitter

Rs 25,000 / Piece

Packaging Size1
UsageGarage Ventilation
BrandAEROSENSE
Product ApplicationsVehicle maintenance facility.
Response TimeWithin 5 minutes
Power Input24VAC

Aerosense Series CMT-100 Carbon Monoxide Transmitter

Series CMT-100 Carbon Monoxide Transmitter

Series CMT-100, Carbon Monoxide Transmitter designed to detect Carbon Monoxide gas in air with analog and RS-485 MODBUS output. Measurement range is upto 250 ppm and optional 300 ppm is available. It is 3-wired supporting and gives current, voltage and RS-485 MODBUS output.

Product Applications:

  • Garage Ventilation
  • Vehicle maintenance facility.
  • Pre-Calibrated
  • Convenient use with varying voltage application.
  • Easily installed at a low cost when used with exclusive case Semiconductor use to measure CO levels.
  • Provides output signal proportional to CO level Model available to interact with other Devices Optimum for parking lot, tunnel & under Ground places
  • General Performance
  • Operating Temperature: -10 to 50°C
  • Operating Humidity: 10-95% RH (Non-Condensing)
  • Storage Temperature: -30 to 60°C
  • Storage Humidity: 0-95% RH (Non-Condensing)
  • Operating Environment:
    • Residential
    • Commercial spaces
    • CO Measurement
    • Sensing Method
    • Semiconductor
  • Measurement range: 0-250 PPM
  • Coverage Area: 4000 to 6000 sq. ft. typical
  • Accuracy:
    • @23°C, 50% RH
    • 0-100 ppm: +10% FS
    • 100-250 ppm: +10% FS
  • Response Time: Within 5 minutes
  • Warm – up time: 2 hours
  • Electrical Data
  • Power Input: 24VAC
  • Output Signal
  • Voltage Output: 2-10 VDC
  • Current Output: 4-20 mA

Aerosense Series CDT-100 Carbon Dioxide Transmitter

Rs 18,500/ Piece

Display TypeDigital
ModelSeries CDT-100
BrandAEROSENSE
Place Of Origindelhi
Reponse Time150 seconds
ApplicationDemand Control Ventilation in schools,office buildings,hospitals and other indoor environments.
ConditionNew

Aerosense Series CDT-100 Carbon Dioxide Transmitter

Series CDT-100 Carbon Dioxide Transmitter

Series CDT-100, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements.

Measurement range upto 10000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • RS-485 MODBUS output: (4-wired) Modicon MODBUS RTU mode, which follow Modicon Modbus protocol-settable address ID switch
  • Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch
  • Power: 24VDC, AC
  • Size: 123mmX70mmX43mm
  • Operating Temperature: -10 to 60˚C For -CS Models: -40 to 40˚C
  • Operating Humidity range: 0 to 95% RH
  • Storage temperature: -30 to 70˚C
  • Storage temperature for cold storage: -40 to 70˚C
  • Measurement range: 0 to 2000/ 3000/ 5000/ 10000 ppm (Selectable by Jumper)
  • Accuracy: ±30ppm ±3%
  • Response time: 150 seconds
  • Response time for cold storage: 70 seconds
  • Sampling interval: 3 sec
Model No.Specifications
CDT-100Carbon Dioxide Transmitter
CDT-100-LCDCarbon Dioxide Transmitter with display
CDT-100-CSCarbon Dioxide Transmitter for cold storage
CDT-100-CS-LCDCarbon Dioxide Transmitter for cold storage with display
CDT-100-M

Carbon Dioxide Transmitter with MODBUS Communication

CDT-100-M-LCD

Carbon Dioxide Transmitter with MODBUS Communication & display

Aerosense Series ECMT200 Carbon Monoxide Transmitter

Rs 7,500 / Piece

Display TypeDigital
Model NumberSeries ECMT200
BrandAEROSENSE
Place Of Origindelhi
Weight0.28 lb (0.11 kg)
ConditionNew

Aerosense Series ECMT200 Carbon Monoxide Transmitter

Series ECMT200 Carbon Monoxide Transmitter

Series ECMT200, Carbon Monoxide Transmitter provides a field selectable current or voltage output that is proportional to the gas concentration in underground parking garages, vehicle maintenance facilities or mechanical rooms. Measurement range is upto 200 ppm. A field replaceable electrochemical sensor provides accurate readings upto 4 years.

Product Applications:

  • Garage Ventilation
  • Mechanical room monitoring
  • Sensor: Field replaceable electrochemical, 4 year typical lifespan. Range: 0 to 200 ppm.
  • Output Drift: <5% per year in air.
  • Coverage Area: 5000 to 7000 sq. ft. typical.
  • Accuracy: ±2% of reading at the time of calibration.
  • Temperature Limits: -4 to 122°F (-20 to 50°C).
  • Storage Temperature: For best sensor life, 32 to 68°F (0 to 20°C). Humidity Limits: 15 to 90% RH constant; 0 to 99% RH intermittent. Response Time: <45 seconds to 90% of final value.
  • Calibration: 15 turn span and zero adjustment potentiometers. Housing: UV resistant polycarbonate.
  • Output: Jumper selectable 4 to 20 mA (loop powered) or 2 to 10 V (load must be >50 KQ).
  • Power Requirements:
    • Current Output: 18 to 28 VDC;
    • Voltage Output: 18 to 28 VDC/VAC, reverse polarity protected.
  • Electrical Connection: Removable terminal block, includes two PG11and one PG 16 knockouts for conduit fitting.
  • Weight: 0.28 lb (0.11 kg)


Digital Differential Pressure Control – Series A4

Rs 1,500 / Piece

BrandSensocon USA

Digital Differential Pressure Control – Series A4

The Series A4 digital differential pressure controller is a patented microprocessor based pressure controller for positive, negative, and differential pressure as well as velocity and flow. The Series A4 differential pressure controller includes (2) 8A SPDT relays and an associated programming menu that allows full configuration of variables such as setpoints, dead band, engineering units, flow coefficients, and more. The programming is done from a user friendly menu on the OLED display or uploaded using an Opti-Link™ programming key. The OLED also displays the exact setpoints or other user defined variables during normal operation. Furthermore, the menu structure can be customized by moving variables to different menu levels to accommodate many applications. Compared to other mechanical products, the Series A4 digital differential pressure controller has a significantly reduced depth, an improved look, and better performance at a similar price.

Customizing Options Available

Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
 

Can your business become better with new trends?

Bring to the table win-win survival strategies to ensure proactive domination. At the end of the day, going forward, a new normal that has evolved from generation X is on the runway heading towards a streamlined cloud solution. User generated content in real-time will have multiple touchpoints for offshoring.

Continue reading “Can your business become better with new trends?”

Business Accounting Wealth & Capital Management

Leverage agile frameworks to provide a robust synopsis for high level overviews. Iterative approaches to corporate strategy foster collaborative thinking to further the overall value proposition. Organically grow the holistic world view of disruptive innovation via workplace diversity and empowerment.

Continue reading “Business Accounting Wealth & Capital Management”

Working Together to Make Investments sucessfull

Capitalize on low hanging fruit to identify a ballpark value added activity to beta test. Override the digital divide with additional clickthroughs from DevOps. Nanotechnology immersion along the information highway will close the loop on focusing solely on the bottom line.

Continue reading “Working Together to Make Investments sucessfull”

Capitalize on low hanging fruit to identify

Leverage agile frameworks to provide a robust synopsis for high level overviews. Iterative approaches to corporate strategy foster collaborative thinking to further the overall value proposition. Organically grow the holistic world view of disruptive innovation via workplace diversity and empowerment.

Continue reading “Capitalize on low hanging fruit to identify”