Magnehelic < DIFFERENTIAL PRESSURE GAUGE < NEAR Dahej Industrial Area GUJARAT

www.envirotechindustrialproduct.co.in

Magnehelic < DIFFERENTIAL PRESSURE GAUGE < NEAR Dahej Industrial Area GUJARAT

 

SERIES 2000 MAGNEHELIC® DIFFERENTIAL PRESSURE GAGES Indicate Positive, Negative or Differential, Accurate within 1%

  • No Power Required
  • Low Cost
  • Used in Isolation/ Hospital Environments and Temporary Units (no power required)

Select the Series 2000 Magnehelic® Gage for a versatile low Differential Pressure Gage With a Wide Choice of 81 Models And 27 options to Choose From. Using Dwyer’s Simple,Frictionless Magnehelic® Gage movement, it quickly indicates air or noncorrosive gas pressures–either positive, negative (vacuum) or Differential.The design resists shock,Vibration, over-pressures and is weatherproof to IP67. Select the -HA High Accuracy Magnehelic® Gage option for an accuracy within 1% of full scale, located below in the Product Configurator.Also included with the–HA option at no extra cost are a mirrored scale overlay and a 6 point calibration certificate.

NIST CALIBRATION available in Product Configurator.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Please see Series AT-2000 for ATEX approved.

California Residents:  Click Here for Proposition 65 WARNING.


PRODUCT APPLICATIONS

  • Filter Monitoring
  • Air Velocity with Dwyer Pitot Tube
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct, Room or Building Pressures
  • Clean Room Positive Pressure Indication

 

 

 

Model Description
2000-1.5KPA Magnehelic Differential Pressure Gage, Range 0-1.5 kPa, minor divisions .05.
2000-10KPA Magnehelic Differential Pressure Gage, Range 0-10 kPa, minor divisions .20.
2000-15KPA Magnehelic Differential Pressure Gage, Range 0-15 kPa, minor divisions .50.
2000-1KPA Magnehelic Differential Pressure Gage, Range 0-1 kPa, minor divisions .02.
2000-20KPA Magnehelic Differential Pressure Gage, Range 0-20 kPa, minor divisions .50.
2000-25KPA Magnehelic Differential Pressure Gage, Range 0-25 kPa, minor divisions .50.
2000-2KPA Magnehelic Differential Pressure Gage, Range 0-2 kPa, minor divisions .05.
2000-30KPA Magnehelic Differential Pressure Gage, Range 0-30 kPa, minor divisions 1.0.
2000-3KPA Magnehelic Differential Pressure Gage, Range 0-3 kPa, minor divisions .10.
2000-4KPA Magnehelic Differential Pressure Gage, Range 0-4 kPa, minor divisions .10.
2000-5KPA Magnehelic Differential Pressure Gage, Range 0-5 kPa, minor divisions .10.
2000-8KPA Magnehelic Differential Pressure Gage, Range 0-8 kPa, minor divisions .20.
2300-1KPA Magnehelic Differential Pressure Gage, Range 0.5-0-0.5 kPa, minor divisions .02.
2300-3KPA Magnehelic Differential Pressure Gage, Range 1.5-0-1.5 kPa, minor divisions .10.

Additional Information:

  • Item Code: Magnehelic DIFFERENTIAL PRESSURE GAUGE NEAR Dahej Industrial Area GUJARAT
  • WhatsApp No.9871034100,9868958924,9650264867,9716640145,8368866030,8368801023
  • www.envirotechindustrialproducts.co.in
  • www.envirotechindustrialproduct.co.in
  • www.envirotechindustrialproduct.in
  • www.envirotechindustrialproducts.in
  • www.envirotechindustrialproduct.com
  • www.envirotechindustrialproducts.com
  • www.envirotechindustrialproducts.net

www.envirotechindustrialproduct.co.in

DWYER OMEGA Magnehelic / GAUGE NEAR Yeshwanthpur Industrial Suburb Bangalore

www.envirotechindia.co.in

DWYER OMEGA Magnehelic I GAUGE NEAR Yeshwanthpur Industrial Suburb Bangalore

Series 2000 DWYER Magnehelic Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine,Resistance of Filter,Wind Speed,Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi

SPECIFICATION

  • Ambient Temperature – -21~140-6~60
  • Rated Pressure -20 inHg~30 inHg (-68~103KPa)
  • Overpressure – Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
  • Process Connections – 1/8″ Female NPT Duplicate High And Low Pressure Taps-One Pair Side And One Pair Back
  • Housing – Die cast aluminum case and bezel, with acrylic cover,Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
  • Accuracy – ±2% of full span at 70 (21 (±3% on-0,and ±4% on -00)
  • Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered

FEATURES

  • OEM/ODM
  • There Is No Need To Fill Liquid To Gauge
  • The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure
  • It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure
  • To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed
  • Exact And Stable Fixed Position Of Needle
  • The Gauge Has Great Antiknock Characteristics
  • There Are 81 Types Of Ranges
  • Minimum is 0-60 Pa And Maximum is 0-21-KPa


PRODUCT APPLICATIONS

  • Filter Monitoring
  • Air Velocity With Pitot Tube
  • Blower Vacuum Monitoring
  • Fan Pressure Indication
  • Duct,Room or Building Pressures
  • Clean Room Positive Pressure Indication

MODELS & ORDERING

DWYER By  Model Number Popularity

 

  • FILTER BY
  • Range-Inches of Water 

 

Model Description
2000-0 MAGNEHELIC® DIFFERENTIAL PRESSURE GAUGE,Range 0-0.50″ w.c.,minor divisions .01,Calibrated for vertical scale position
2000-00 MAGNEHELIC® DIFFERENTIAL PRESSURE GAUGE,Range 0-0.25″ w.c.,minor divisions .005,Calibrated for vertical scale position
2001 MAGNEHELIC® DIFFERENTIAL PRESSURE GAUGE,Range 0-1.0″ w.c.,minor divisions .02.
2002 MAGNEHELIC® DIFFERENTIAL PRESSURE GAUGE,Range 0-2.0″ w.c.,minor divisions .05.
2003 MAGNEHELIC® DIFFERENTIAL PRESSURE GAUGE,Range 0-3.0″ w.c.,minor divisions .10.
2004 MAGNEHELIC® DIFFERENTIAL PRESSURE GAUGE,Range 0-4.0″ w.c.,minor divisions .10.
2005 MAGNEHELIC® DIFFERENTIAL PRESSURE GAUGE,Range 0-5.0″ w.c.,minor divisions .10.
2006 MAGNEHELIC® DIFFERENTIAL PRESSURE GAUGE,Range 0-6.0″ w.c.,minor divisions .20.

 

Additional Information:

www.envirotechindia.co.in

Dwyer 1950 Explosion Proof Differential Pressure Switch Wholesaler Delhi India

Dwyer Instruments 1950-1-2F

 
Minimum Order Quantity3 Number
Country of OriginMade in India
Switch TypeSingle-Pole Double-Throw (SPDT)
Current Rating15 A @, 125, 250, 480 VAC, 60 Hz Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
BrandDWYER USA
Model Name/NumberDwyer 1950-1-2F
Power/Voltage15 A @, 125, 250, 480 VAC, 60 Hz Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
Process Connections1/8″ Female NPT.

Dwyer Instruments 1950-1-2F

  • Dwyer 1950-1-2F Explosion-Proof 
  • Differential Pressure Switch (0.4-1.6″ w.c.)
  • Model: 1950-1-2F

Combines The Best Features of The Popular Dwyer® Series 1900 Pressure Switch With An Integral Explosion-Proof And Weatherproof Housing, Making It An Exceptional Value For Either Application. It is CE, UL and CSA listed, FM Approved For Use in Class I, Div 1, Groups C and D, Class II Groups E, F, and G and Class III Hazardous Atmospheres NEMA 7 & 9.

DESCRIPTION

  • Dwyer 1950-1-2F Offers
  • Dwyer 1950 Series Offers
  • UL and CSA listed, and FM approved.
  • CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.

Dwyer 1950-1-2F Specifications

  • Service –Air and Non-Combustible, Compatible Gases
  • Temperature Limits -40 to 140°F (-40 to 60°C)
  • 0 to 140°F (-17.8 to 60°C) for 1950P-8, 15, 25, and 50
  • -30 to 130°F (-34.4 to 54.4°C) for 1950-02
  • Pressure Limits-Continuous: 1950’s – 45 in w.c. (0.11 bar); 1950P’s – 35 psi (2.41 bar); 1950P-50 only – 70 psi (4.83 bar)
  • Surge: 1950’s – 10 psi (0.69 bar), 1950P’s – 50 psi (3.45 bar), 1950P-50 only – 90 psi (6.21 bar)
  • Enclosure Rating-NEMA 3 (IP54), NEMA 7 & 9
  • Switch Type-Single-Pole Double-Throw (SPDT)
  • Electrical Rating-15 A @, 125, 250, 480 VAC, 60 Hz
  • Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
  • Electrical Connections-3 Screw Types: Common, Normally Open and Normally Closed
  • Process Connections-1/8″ Female NPT
  • Mounting Orientation-Diaphragm in Vertical Position
  • Set Point Adjustment-Screw Type On Top of Housing
  • Weight-3.25 Ib (1.5 kg)
  • 1950-02 Model: 4.4 lb (2 kg)
  • Agency Approvals-CE, CSA, FM, UL

Dwyer 1950-10-2F Differential Pressure Switch

 
Minimum Order Quantity3 Number
BrandDWYER USA
Media TypeAir And Non-Combustible,Compatible Gases.
Contact System TypeSingle-Pole Double-Throw (SPDT).
Electrical Connection3 Screw Type,Common,Normally Open And Normally Closed.
Model Name/NumberDwyer 1950-10-2F Differential Pressure Switch
Power/Voltage15 A @ 125,250,480 VAC,60 Hz. Resistive 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC,60 Hz.
Weight3.25 lb (1.5 kg); 1950-02 Model 4.4 lb (2 kg).
Mounting TypeDiaphragm in Vertical Position.Consult Factory For Other Position Orientations.
Minimum Order Quantity3 NOS
Country of OriginMade in India

Dwyer 1950-10-2F Differential Pressure Switch

Dwyer 1950-10-2F Explosion Proof Differential Pressure Switch

  • Dwyer 1950-10-2F Explosion-Proof 
  • Differential Pressure Switch (3.0-11″ w.c.)
  • Model: 1950-10-2F

Combines The Best Features of The Popular Dwyer® Series 1900 Pressure Switch With An Integral Explosion-Proof And Weatherproof Housing, Making It An Exceptional Value For Either Application. It is CE, UL and CSA listed, FM Approved For Use in Class I, Div 1, Groups C and D, Class II Groups E, F, and G and Class III Hazardous Atmospheres NEMA 7 & 9.

DESCRIPTION

  • Dwyer 1950-10-2F Offers
  • Dwyer 1950 Series Offers
  • UL and CSA listed, and FM approved.
  • CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.

Dwyer 1950-10-2F Specifications

  • Service –Air and Non-Combustible, Compatible Gases
  • Temperature Limits -40 to 140°F (-40 to 60°C)
  • 0 to 140°F (-17.8 to 60°C) for 1950P-8, 15, 25, and 50
  • -30 to 130°F (-34.4 to 54.4°C) for 1950-02
  • Pressure Limits-Continuous: 1950’s – 45 in w.c. (0.11 bar); 1950P’s – 35 psi (2.41 bar); 1950P-50 only – 70 psi (4.83 bar)
  • Surge: 1950’s – 10 psi (0.69 bar), 1950P’s – 50 psi (3.45 bar), 1950P-50 only – 90 psi (6.21 bar)
  • Enclosure Rating-NEMA 3 (IP54), NEMA 7 & 9
  • Switch Type-Single-Pole Double-Throw (SPDT)
  • Electrical Rating-15 A @, 125, 250, 480 VAC, 60 Hz
  • Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
  • Electrical Connections-3 Screw Types: Common, Normally Open and Normally Closed
  • Process Connections-1/8″ Female NPT
  • Mounting Orientation-Diaphragm in Vertical Position
  • Set Point Adjustment-Screw Type On Top of Housing
  • Weight-3.25 Ib (1.5 kg)
  • 1950-02 Model: 4.4 lb (2 kg)
  • Agency Approvals-CE, CSA, FM, UL

Dwyer Series 1950 Explosion Proof Differential Pressure Switch

 
Minimum Order Quantity3 Piece
BrandDWYER USA
Media TypeAir And Non-Combustible,Compatible Gases.
Contact System TypeSingle-Pole Double-Throw (SPDT).
Electrical Connection3 Screw Type,Common,Normally Open And Normally Closed.
Model Name/NumberDwyer Series 1950 Explosion Proof Differential Pressure Switch
Power/Voltage15 A @ 125,250,480 VAC,60 Hz. Resistive 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC,60 Hz.
Weight3.25 lb (1.5 kg); 1950-02 Model 4.4 lb (2 kg).
Mounting TypeDiaphragm in Vertical Position.Consult Factory For Other Position Orientations.
Minimum Order Quantity3 NOS
Country of OriginMade in India


Dwyer Series 1950 Explosion Proof Differential Pressure Switch

  • Set Points from .03 to 20 in w.c., Explosion-Proof And Weatherproof


Series 1950 Explosion-Proof Differential Pressure Switch Combines The Best Features Of The Popular Dwyer® Series 1900 Pressure Switch With an Integral Explosion-Proof And Weatherproof Housing, Making it An Exceptional Value For Either Application. It is CE, UL and CSA listed, FM Approved For use in Class I, Div 1, Groups C and D, Class II Groups E, F, and G and Class III hazardous atmospheres (NEMA 7 & 9), Raintight NEMA 3 (IP54). Weatherproof features include a drain plug and O-ring seal in cover. Electrical connections are easily made by removing front cover. For convenience the set point adjustment screw is located on the outside of the housing. Twelve models offer set points from .03 to 20 in w.c. (0.0075 to 5 kPa) and from .5 to 50 psi (0.035 to 3.5 bar). The unit is very light and compact — about half the weight and bulk of other Explosion-Proof or Weather-Proof Switches with Separate Enclosures.

CAUTION:
 For Use Only With Air or Compatible Gases. Applications With Hazardous Atmospheres and a single Positive Pressure May Require Special Venting.

PRODUCT APPLICATIONS

  • HVAC Applications
  • Process Applications
  • All-Weather Applications


MODELS & ORDERING

Model Description

  • 1950-0-2F-Range .15-.50″ w.c., approx. Deadband @ min. set point 0.10, approx. deadband @ max. set point 0.15.
  • 1950-00-2F-Range .07-.15″ w.c., approx. deadband @ min. set point 0.04, approx. deadband @ max. set point 0.05.
  • 1950-02-2S-Range .03-.10″ w.c., approx. deadband @ min. set point 0.025, approx. deadband @ max. set point 0.05.
  • 1950-1-2F-Range .4-1.6″ w.c., approx. deadband @ min. set point 0.15, approx. deadband @ max. set point 0.20.
  • 1950-10-2F-Range 3-11″ w.c., approx. deadband @ min. set point 0.40, approx. deadband @ max. set point 0.50.
  • 1950-20-2F-Range 4-20″ w.c., approx. deadband @ min. set point 0.40, approx. deadband @ max. set point 0.60.
  • 1950-5-2F-Range 1.4-5.5″ w.c., approx. deadband @ min. set point 0.30, approx. deadband @ max. set point 0.40.
  • 1950P-15-2F-Range 3-15 psid, approx. deadband @ min. set point 0.9, approx. deadband @ max. set point 0.9.
  • 1950P-2-2F-Range-0.5-2 psid, approx. deadband @ min. set point 0.3, approx. deadband @ max. set point 0.3.
  • 1950P-25-2F-Range 4-25 psid, approx. deadband @ min. set point 0.7, approx. deadband @ max. set point 0.7.
  • 1950P-50-2F-Range 15-50 psid, approx. deadband @ min. set point 1.0, approx. deadband @ max. set point 1.5.
  • 1950P-8-2F-Range 1.5-8 psid, approx. deadband @ min. set point 1.0, approx. deadband @ max. set point 1.0.


FEATURES

  • Explosion-Proof and Weatherproof Housing Provides Device Protection For Outdoor Use or Harsh Environment Operation
  • External Set Point Screw Provides Easy Access That Simplifies Making Adjustments Without Opening or Disassembling Enclosure
  • Easily Accessible Electrical Connection Simplifies The Installation

Dwyer 1950-10-2F Explosion Proof Differential Pressure Switch

 
Minimum Order Quantity3 Piece
Switch TypeSingle-Pole Double-Throw (SPDT)
BrandDwyer USA
Model Name/Number1950-10-2F
Power/Voltage15 A @,125,250,480 VAC,60 Hz Resistive 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC,60 Hz
Material/BodyMetal
Contact TypeDwyer 1950-10-2F Explosion Proof Differential Pressure Switch
Country of OriginMade in India

Dwyer 1950-10-2F Explosion Proof Differential Pressure Switch

Dwyer 1950-10-2F Explosion Proof Differential Pressure Switch

  • Dwyer 1950-10-2F Explosion-Proof 
  • Differential Pressure Switch (3.0-11″ w.c.)
  • Model: 1950-10-2F

Combines The Best Features of The Popular Dwyer® Series 1900 Pressure Switch With An Integral Explosion-Proof And Weatherproof Housing, Making It An Exceptional Value For Either Application. It is CE, UL and CSA listed, FM Approved For Use in Class I, Div 1, Groups C and D, Class II Groups E, F, and G and Class III Hazardous Atmospheres NEMA 7 & 9.

DESCRIPTION

  • Dwyer 1950-10-2F Offers
  • Dwyer 1950 Series Offers
  • UL and CSA listed, and FM approved.
  • CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.

Dwyer 1950-10-2F Specifications

  • Service –Air and Non-Combustible, Compatible Gases
  • Temperature Limits -40 to 140°F (-40 to 60°C)
  • 0 to 140°F (-17.8 to 60°C) for 1950P-8, 15, 25, and 50
  • -30 to 130°F (-34.4 to 54.4°C) for 1950-02
  • Pressure Limits-Continuous: 1950’s – 45 in w.c. (0.11 bar); 1950P’s – 35 psi (2.41 bar); 1950P-50 only – 70 psi (4.83 bar)
  • Surge: 1950’s – 10 psi (0.69 bar), 1950P’s – 50 psi (3.45 bar), 1950P-50 only – 90 psi (6.21 bar)
  • Enclosure Rating-NEMA 3 (IP54), NEMA 7 & 9
  • Switch Type-Single-Pole Double-Throw (SPDT)
  • Electrical Rating-15 A @, 125, 250, 480 VAC, 60 Hz
  • Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
  • Electrical Connections-3 Screw Types: Common, Normally Open and Normally Closed
  • Process Connections-1/8″ Female NPT
  • Mounting Orientation-Diaphragm in Vertical Position
  • Set Point Adjustment-Screw Type On Top of Housing
  • Weight-3.25 Ib (1.5 kg)
  • 1950-02 Model: 4.4 lb (2 kg)
  • Agency Approvals-CE, CSA, FM, UL
 

Dwyer 1950-1-2F Explosion Proof Differential Pressure Switch

 
Minimum Order Quantity3 Number
Switch TypeSingle-Pole Double-Throw (SPDT)
Current Rating15 A @,125,250,480 VAC,60 Hz Resistive 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC,60 Hz
BrandDWYER USA
Model Name/NumberDwyer 1950-1-2F
Power/Voltage15 A @,125,250,480 VAC,60 Hz Resistive 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC,60 Hz
Material/BodyMetal
Country of OriginMade in India

Dwyer 1950-1-2F Explosion Proof Differential Pressure Switch

  • Dwyer 1950-1-2F Explosion-Proof 
  • Differential Pressure Switch (0.4-1.6″ w.c.)
  • Model: 1950-1-2F

Combines The Best Features of The Popular Dwyer® Series 1900 Pressure Switch With An Integral Explosion-Proof And Weatherproof Housing, Making It An Exceptional Value For Either Application. It is CE, UL and CSA listed, FM Approved For Use in Class I, Div 1, Groups C and D, Class II Groups E, F, and G and Class III Hazardous Atmospheres NEMA 7 & 9.

DESCRIPTION

  • Dwyer 1950-1-2F Offers
  • Dwyer 1950 Series Offers
  • UL and CSA listed, and FM approved.
  • CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.

Dwyer 1950-1-2F Specifications

  • Service –Air and Non-Combustible, Compatible Gases
  • Temperature Limits -40 to 140°F (-40 to 60°C)
  • 0 to 140°F (-17.8 to 60°C) for 1950P-8, 15, 25, and 50
  • -30 to 130°F (-34.4 to 54.4°C) for 1950-02
  • Pressure Limits-Continuous: 1950’s – 45 in w.c. (0.11 bar); 1950P’s – 35 psi (2.41 bar); 1950P-50 only – 70 psi (4.83 bar)
  • Surge: 1950’s – 10 psi (0.69 bar), 1950P’s – 50 psi (3.45 bar), 1950P-50 only – 90 psi (6.21 bar)
  • Enclosure Rating-NEMA 3 (IP54), NEMA 7 & 9
  • Switch Type-Single-Pole Double-Throw (SPDT)
  • Electrical Rating-15 A @, 125, 250, 480 VAC, 60 Hz
  • Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
  • Electrical Connections-3 Screw Types: Common, Normally Open and Normally Closed
  • Process Connections-1/8″ Female NPT
  • Mounting Orientation-Diaphragm in Vertical Position
  • Set Point Adjustment-Screw Type On Top of Housing
  • Weight-3.25 Ib (1.5 kg)
  • 1950-02 Model: 4.4 lb (2 kg)
  • Agency Approvals-CE, CSA, FM, UL

Dwyer 1950-1-2F Differential Pressure Switch

 
Minimum Order Quantity3 Number
BrandDWYER USA
Current Rating15 A @,125,250,480 VAC,60 Hz Resistive 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC,60 Hz
Media TypeAir And Non-Combustible,Compatible Gases.
Range SettingDwyer 1950-1-2F Differential Pressure Switch
Contact System TypeSingle-Pole Double-Throw (SPDT).
Electrical Connection3 Screw Type,Common,Normally Open And Normally Closed.
Model Name/NumberDwyer 1950-1-2F Differential Pressure Switch
Power/Voltage15 A @ 125,250,480 VAC,60 Hz. Resistive 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC,60 Hz.
Weight3.25 lb (1.5 kg); 1950-02 Model 4.4 lb (2 kg).
Mounting TypeDiaphragm in Vertical Position.Consult Factory For Other Position Orientations.
Minimum Order Quantity3 NOS
Country of OriginMade in India

Dwyer 1950-1-2F Differential Pressure Switch

  • Dwyer 1950-1-2F Explosion-Proof 
  • Differential Pressure Switch (0.4-1.6″ w.c.)
  • Model: 1950-1-2F

Combines The Best Features of The Popular Dwyer® Series 1900 Pressure Switch With An Integral Explosion-Proof And Weatherproof Housing, Making It An Exceptional Value For Either Application. It is CE, UL and CSA listed, FM Approved For Use in Class I, Div 1, Groups C and D, Class II Groups E, F, and G and Class III Hazardous Atmospheres NEMA 7 & 9.

DESCRIPTION

  • Dwyer 1950-1-2F Offers
  • Dwyer 1950 Series Offers
  • UL and CSA listed, and FM approved.
  • CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.

Dwyer 1950-1-2F Specifications

  • Service –Air and Non-Combustible, Compatible Gases
  • Temperature Limits -40 to 140°F (-40 to 60°C)
  • 0 to 140°F (-17.8 to 60°C) for 1950P-8, 15, 25, and 50
  • -30 to 130°F (-34.4 to 54.4°C) for 1950-02
  • Pressure Limits-Continuous: 1950’s – 45 in w.c. (0.11 bar); 1950P’s – 35 psi (2.41 bar); 1950P-50 only – 70 psi (4.83 bar)
  • Surge: 1950’s – 10 psi (0.69 bar), 1950P’s – 50 psi (3.45 bar), 1950P-50 only – 90 psi (6.21 bar)
  • Enclosure Rating-NEMA 3 (IP54), NEMA 7 & 9
  • Switch Type-Single-Pole Double-Throw (SPDT)
  • Electrical Rating-15 A @, 125, 250, 480 VAC, 60 Hz
  • Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
  • Electrical Connections-3 Screw Types: Common, Normally Open and Normally Closed
  • Process Connections-1/8″ Female NPT
  • Mounting Orientation-Diaphragm in Vertical Position
  • Set Point Adjustment-Screw Type On Top of Housing
  • Weight-3.25 Ib (1.5 kg)
  • 1950-02 Model: 4.4 lb (2 kg)
  • Agency Approvals-CE, CSA, FM, UL

SERIES 1950 EXPLOSION-PROOF DIFFERENTIAL PRESSURE
SWITCH

 
Minimum Order Quantity3 Number
BrandDWYER USA
Current Rating15 A @ 125,250,480 VAC,60 Hz. Resistive 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC,60 Hz.
Media TypeAir And Non-Combustible,Compatible Gases.
Contact System TypeSingle-Pole Double-Throw (SPDT).
Electrical Connection3 Screw Type,Common,Normally Open And Normally Closed.
Model Name/NumberSeries 1950 Explosion Proof Differential Pressure Switch
Power/Voltage15 A @ 125,250,480 VAC,60 Hz. Resistive 1/8 HP @ 125 VAC,1/4 HP @ 250 VAC,60 Hz.
Weight3.25 lb (1.5 kg); 1950-02 Model 4.4 lb (2 kg).
Mounting TypeDiaphragm in Vertical Position.Consult Factory For Other Position Orientations.
Minimum Order Quantity3 NOS
Country of OriginMade in India

SERIES 1950 EXPLOSION-PROOF DIFFERENTIAL PRESSURE
SWITCH

  • Set Points from .03 to 20 in w.c., Explosion-Proof And Weatherproof

Series 1950 Explosion-Proof Differential Pressure Switch Combines The Best Features Of The Popular Dwyer® Series 1900 Pressure Switch With an Integral Explosion-Proof And Weatherproof Housing, Making it An Exceptional Value For Either Application. It is CE, UL and CSA listed, FM Approved For use in Class I, Div 1, Groups C and D, Class II Groups E, F, and G and Class III hazardous atmospheres (NEMA 7 & 9), Raintight NEMA 3 (IP54). Weatherproof features include a drain plug and O-ring seal in cover. Electrical connections are easily made by removing front cover. For convenience the set point adjustment screw is located on the outside of the housing. Twelve models offer set points from .03 to 20 in w.c. (0.0075 to 5 kPa) and from .5 to 50 psi (0.035 to 3.5 bar). The unit is very light and compact — about half the weight and bulk of other Explosion-Proof or Weather-Proof Switches with Separate Enclosures.

CAUTION:
 For Use Only With Air or Compatible Gases. Applications With Hazardous Atmospheres and a single Positive Pressure May Require Special Venting.

PRODUCT APPLICATIONS

  • HVAC Applications
  • Process Applications
  • All-Weather Applications

MODELS & ORDERING

Model Description

  • 1950-0-2F-Range .15-.50″ w.c., approx. Deadband @ min. set point 0.10, approx. deadband @ max. set point 0.15.
  • 1950-00-2F-Range .07-.15″ w.c., approx. deadband @ min. set point 0.04, approx. deadband @ max. set point 0.05.
  • 1950-02-2S-Range .03-.10″ w.c., approx. deadband @ min. set point 0.025, approx. deadband @ max. set point 0.05.
  • 1950-1-2F-Range .4-1.6″ w.c., approx. deadband @ min. set point 0.15, approx. deadband @ max. set point 0.20.
  • 1950-10-2F-Range 3-11″ w.c., approx. deadband @ min. set point 0.40, approx. deadband @ max. set point 0.50.
  • 1950-20-2F-Range 4-20″ w.c., approx. deadband @ min. set point 0.40, approx. deadband @ max. set point 0.60.
  • 1950-5-2F-Range 1.4-5.5″ w.c., approx. deadband @ min. set point 0.30, approx. deadband @ max. set point 0.40.
  • 1950P-15-2F-Range 3-15 psid, approx. deadband @ min. set point 0.9, approx. deadband @ max. set point 0.9.
  • 1950P-2-2F-Range-0.5-2 psid, approx. deadband @ min. set point 0.3, approx. deadband @ max. set point 0.3.
  • 1950P-25-2F-Range 4-25 psid, approx. deadband @ min. set point 0.7, approx. deadband @ max. set point 0.7.
  • 1950P-50-2F-Range 15-50 psid, approx. deadband @ min. set point 1.0, approx. deadband @ max. set point 1.5.
  • 1950P-8-2F-Range 1.5-8 psid, approx. deadband @ min. set point 1.0, approx. deadband @ max. set point 1.0.

FEATURES

  • Explosion-Proof and Weatherproof Housing Provides Device Protection For Outdoor Use or Harsh Environment Operation
  • External Set Point Screw Provides Easy Access That Simplifies Making Adjustments Without Opening or Disassembling Enclosure
  • Easily Accessible Electrical Connection Simplifies The Installation

Dwyer Instruments 1950-10-2F

 
Minimum Order Quantity3 Number
Switch TypeSingle-Pole Double-Throw (SPDT)
BrandDwyer USA
Model Name/Number1950-10-2F
Material/BodyMetal
Contact TypeDwyer Instruments 1950-10-2F
Country of OriginMade in India

Dwyer Instruments 1950-10-2F

Dwyer 1950-10-2F Explosion Proof Differential Pressure Switch

  • Dwyer 1950-10-2F Explosion-Proof 
  • Differential Pressure Switch (3.0-11″ w.c.)
  • Model: 1950-10-2F

Combines The Best Features of The Popular Dwyer® Series 1900 Pressure Switch With An Integral Explosion-Proof And Weatherproof Housing, Making It An Exceptional Value For Either Application. It is CE, UL and CSA listed, FM Approved For Use in Class I, Div 1, Groups C and D, Class II Groups E, F, and G and Class III Hazardous Atmospheres NEMA 7 & 9.

DESCRIPTION

  • Dwyer 1950-10-2F Offers
  • Dwyer 1950 Series Offers
  • UL and CSA listed, and FM approved.
  • CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.

Dwyer 1950-10-2F Specifications

  • Service –Air and Non-Combustible, Compatible Gases
  • Temperature Limits -40 to 140°F (-40 to 60°C)
  • 0 to 140°F (-17.8 to 60°C) for 1950P-8, 15, 25, and 50
  • -30 to 130°F (-34.4 to 54.4°C) for 1950-02
  • Pressure Limits-Continuous: 1950’s – 45 in w.c. (0.11 bar); 1950P’s – 35 psi (2.41 bar); 1950P-50 only – 70 psi (4.83 bar)
  • Surge: 1950’s – 10 psi (0.69 bar), 1950P’s – 50 psi (3.45 bar), 1950P-50 only – 90 psi (6.21 bar)
  • Enclosure Rating-NEMA 3 (IP54), NEMA 7 & 9
  • Switch Type-Single-Pole Double-Throw (SPDT)
  • Electrical Rating-15 A @, 125, 250, 480 VAC, 60 Hz
  • Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz
  • Electrical Connections-3 Screw Types: Common, Normally Open and Normally Closed
  • Process Connections-1/8″ Female NPT
  • Mounting Orientation-Diaphragm in Vertical Position
  • Set Point Adjustment-Screw Type On Top of Housing
  • Weight-3.25 Ib (1.5 kg)
  • 1950-02 Model: 4.4 lb (2 kg)
  • Agency Approvals-CE, CSA, FM, UL