Nicotra Forward Curved Centrifugal Fan ADH 250 R

www.envirotechdelhi.net

Nicotra Forward Curved Centrifugal Fan ADH 250 R

Nicotra Forward Curved Centrifugal Fan ADH 250 R is a Compact, High-Performance Centrifugal Fan Designed for Efficient Air Movement in HVAC Systems, Air Handling Units (AHU), Ventilation, And Air Exhaust Applications. Its Forward-Curved Centrifugal Design Provides Reliable Air Flow With Smooth And Quiet Operation. The ADH Series is Listed by AMCA as a Forward Curved DWDI (Double Width Double Inlet) Centrifugal Fan Range.

Key Features:

  • Model: ADH 250 R
  • Type: Forward Curved Centrifugal Fan
  • Configuration: DWDI – Double Width Double Inlet
  • Suitable for: AHU, HVAC, Industrial Ventilation & Air Exhaust
  • Compact And Durable Construction
  • Reliable Performance And Low-Noise Operation
  • Suitable For Continuous Air Circulation And Ventilation Applications


Note:
 Actual Airflow, Static Pressure, Motor Power, RPM, And Efficiency Depend On The Selected Operating Point And Fan Configuration.

Applications – Nicotra Forward Curved Centrifugal Fan ADH 250 R

  • Air Handling Units (AHU)
  • HVAC Systems
  • Industrial Ventilation
  • Air Conditioning Systems
  • Fresh Air Supply
  • Air Circulation Systems
  • Exhaust & Ventilation Systems
  • Factory & Commercial Building Ventilation
  • Heating and Cooling Systems
  • General Industrial Air Movement

The ADH Series Is a Forward-Curved, Double-Width Double-Inlet (DWDI) Centrifugal Fan Family Suitable For Commercial And Industrial Applications.

Product Specifications – Nicotra Forward Curved Centrifugal Fan ADH 250 R 

 

  • Model: ADH 250 R
  • Fan Type: Forward Curved Centrifugal Fan
  • Impeller Diameter: 250 mm
  • Number of Blades: 38
  • Motor Power: 0.37 kW
  • Airflow / Flow Rate: Up to 1,600 m³/h
  • Static Pressure: Up to 370 Pa
  • Motor Speed: 2,800 RPM
  • Noise Level: Approx. 65 dB(A)
  • Voltage: 230 V
  • Frequency: 50 Hz
  • Material: Galvanized Steel
  • Weight: Approx. 10 kg
  • Dimension (L × W × H): Approx. 340 × 250 × 290 mm
  • Insulation Class: Class F
  • Operating Temperature: -20°C to +60°C
  • Bearing Type: Ball Bearing
  • Mounting Type: Base Mounted
  • Application: HVAC, AHU, Ventilation, Air Handling Units
  • Drive: Direct Drive

Note: Exact Performance Depends On The Specific ADH 250 Configuration And Operating Point. The Nicotra Technical Data Confirms The 250 MM Impeller Size And 38 Blades; The Above Product-Listing Specifications Are From A Supplier Listing.

Additional Information:

  • Item Code: Nicotra Forward Curved Centrifugal Fan ADH 250 R
  • WhatsApp No.9871034100,9868958924,9650264867,9716640145,8368866030,8368801023
  • www.envirotechindia.co.in
  • www.envirotechdelhi.in
  • www.envirotechdelhi.net
  • www.envirotechindia.info
  • www.envirotechdelhi.info
  • www.envirotechindia.net
  • www.envirotechdelhi.co.in

www.envirotechdelhi.net

Nicotra Forward Curved Centrifugal Fan ADH 200 R

www.envirotechindustrialproducts.in

Nicotra Forward Curved Centrifugal Fan ADH 200 R

Nicotra Forward Curved Centrifugal Fan ADH 200 R is a Compact And Efficient Double-Inlet, Forward-Curved Centrifugal Fan Designed For HVAC, Air Handling Units (AHUs), Ventilation, And Industrial Air Circulation Applications. It Features a Robust Galvanized-Steel Scroll Casing And Dynamically Balanced Forward-Curved Impeller For Reliable Airflow, Quiet Operation, And Long Service Life. The ADH Series is Recognized as a Forward-Curved DWDI Centrifugal Fan Range.


Key Features:

 

  • High-Efficiency Forward-Curved Impeller
  • Double-Inlet Centrifugal Fan Design
  • Compact and Durable Construction
  • Suitable For AHU And HVAC Systems
  • Low-Noise Operation
  • Reliable Airflow Performance
  • Suitable For Industrial And Commercial Ventilation Applications
  • Available for Replacement and Retrofit Requirements


Applications – Nicotra Forward Curved Centrifugal Fan ADH 200 R

 

  • Air Handling Units (AHU)
  • HVAC Systems
  • Industrial Ventilation
  • Commercial Building Ventilation
  • Fresh Air & Exhaust Air Systems
  • Cleanroom Ventilation
  • Pharmaceutical Industry
  • Hospital & Healthcare Facilities
  • Textile Industry
  • Food Processing Industry
  • Factory & Warehouse Ventilation
  • Cooling & Air Circulation Systems
  • Industrial Air Conditioning


Product Specifications – Nicotra Forward Curved Centrifugal Fan ADH 200 R

 

  • Brand: Nicotra Gebhardt
  • Model: ADH 200 R
  • Fan Type: Forward Curved Centrifugal Fan
  • Impeller Diameter: 200 mm
  • Number of Blades: 38
  • Impeller Weight: Approx. 1.6 kg
  • Impeller Moment of Inertia: 0.014 kg·m²
  • Construction: Galvanized Steel
  • Fan Design: Double-Inlet / DWDI
  • Application: HVAC, AHU & Industrial Ventilation
  • Balance Grade: DIN 24166, Grade 2

The 200 MM Impeller Diameter, 38 Blades, 1.6 kg Impeller Weight, And 0.014 kg·m² Moment of Inertia are listed in Nicotra’s ADH E_-0200 Technical Data; the ADH Range is Also Certified as a Forward-Curved DWDI Centrifugal Fan Family.

Additional Information:

  • Item Code: Nicotra Forward Curved Centrifugal Fan ADH 200 R
  • WhatsApp No.9871034100,9868958924,9650264867,9716640145,8368866030,8368801023
  • www.envirotechindustrialproducts.co.in
  • www.envirotechindustrialproduct.co.in
  • www.envirotechindustrialproduct.in
  • www.envirotechindustrialproducts.in
  • www.envirotechindustrialproduct.com
  • www.envirotechindustrialproducts.com
  • www.envirotechindustrialproducts.net

www.envirotechindustrialproducts.in